← All vessels
ZOGRAFIA
Freight Ship · Bulk Carrier class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named ZOGRAFIA
ZOGRAFIA is a 2002 freight ship. The Coast Guard has recorded 18 inspections since 2003, most recently in January 2019, along with 19 deficiencies and 4 operational controls.
Records from 2003 to 2019. Most recent: inspection, 15 January 2019.
- Built
- 2002
- Last inspected
- 15 January 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9222338 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HIU8
609012
Flag
MALTA
—
Maury page id
psix-609012
Inspections, by type
…with no type recorded7
Years with a record
8 calendar years (2003–2019)
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it31167 - Convention (Subpart B), Gross Ton
31167 - Regulatory (Subpart C or D), Gross Ton
17541 - Convention (Subpart B), Net Ton
53649 - Dead Weight, Ton
63623 - Displacement, Ton
31167 - Regulatory (Subpart C or D), Gross Ton
17541 - Convention (Subpart B), Net Ton
53649 - Dead Weight, Ton
63623 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
15 January 2019
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6613721
16 December 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam · COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6598403
12 July 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5937581
10 February 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4241861
10 February 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4242062
10 February 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4242201
9 February 2012
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4235384
16 November 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3099422
16 November 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3099848
30 October 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3089711
25 May 2006
MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2658524
8 March 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2020541
7 March 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2021394
2 March 2004
Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2016188
26 September 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1914704
26 September 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1919781
21 September 2003
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1890199
1 March 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1751186
Deficiency record · 19
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 December 2018
Resolved
The detection of smoke or other products of combustion shall initiate a visual and audible signal at the control panel and the navigation bridge.
The smoke detection alarm panel on the navigation bridge was inoperable. As such, no alarms would be received on the navigation bridge. 74SOLAS(01) II-2/13-1.1.6 50 a,c
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 December 2018
Resolved
Every liferaft shall be stowed with its painter permanently attached to the ship. The painter on the starboard side liferaft was not attached to the ship. The ships crew attached the painter to correct. 74SOLAS(14) III/13.4.1 10c
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 December 2018
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chaffing or other damage.
The emergency generator panel had a wire spliced into a spare breaker and the wire was fed through the front of the panel such that it was pinched in the door. The crew removed the wiring to correct.
74SOLAS(04) II-1/45.5.5 10c
Lifesaving › Inflatable Liferafts › Not on Board
Issued 12 July 2016
Resolved
0620 - Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be ready for immediate use. Starboard side life raft required by Form E of the SOLAS Cargo Ship Safety Certificate is missing from vessel. 74SOLAS(14)III/20.2
Engineering › Compressed Air System (start air) › Valve
Issued 10 February 2012
Resolved
The vessel experienced a propulsion irregularity while in the Mississippi River.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 9 February 2012
Resolved
1581-Rudder angle indicator-The ship and equipment shall maintain with provisions of present regs to ensure the ship will remain fit for sea. PSCO found rudder angle indicator and true position of rudder matched at times during tests and at other times a disparity between the 2 up to 5 degrees. Provide doc. from class by COB 12FEB12 attesting to angle indicator and true position. SOLAS 74a I/11
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 9 February 2012
Resolved
0899-Other (acid prevent)-Each transfer pipe system must not leak under static liquid pressure test at 1.5 times the maximum allowable working pressure. The frequency of this test must be annually. Vessel conducted test using air as test medium. Provide doc that the transfer pipes were hydrostatically tested to 1.5 times MAWP prior to bunkering or L/O transfer in US waters. 33CFR 156.170
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 November 2007
Resolved
Pilot onboard complained that the bank on the screen display was pulling.
Navigation › Piloting/Steering › Marine Charts
Issued 12 June 2006
Resolved
In order to safely navigate and meet the requirements of 33 CFR 164, chart number #18651 need to be on board.
Documentation › Logs/Records › Oil Record Book
Issued 12 June 2006
Resolved
Chief Engineer is using the code "E" when operating the OWS. He should be using "D". Reviewed the requirements with the Chief Engineer and Master.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 12 June 2006
Resolved
The [name withheld] has not been keeping records of when garbage in burned in the incinerator. He assumed that since it was located in the engine room. He did need to record the burning of oily rags, paper, gasket material and other items in the garbage log. Educated the Master, C/O and C/E of the MARPOL requirements regarding garbage.
Personnel › Training › Fire Fighting Basic
Issued 12 June 2006
Resolved
One fire training manual is missing from the crew's lounge. A copy needs to made of the one on board and placed in the crew's lounge in order to meet SOLAS 74 AM, II-2/16.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 12 June 2006
Resolved
The MSD is not being maintained as per manufacturer’s requirements. Class has issued a certificate indicating the system meets the requirements of MARPOL IV. Daily, weekly, monthly, semi-annual and annual inspections are not being conducted or if they are done they are not being properly recorded. Educated the Master and Chief Engineer of MARPOL requirements. Correct prior to next US after foreign
Engineering › Diesel Engine (propulsion-direct drive)
Issued 2 March 2004
Resolved
MDE JACKET WATER IS LEAKING IWO CYLINDERS. LEGACY COMPONENT DESC: Cylinder Head
Lifesaving › Lifeboat Equipment
Issued 1 March 2003
Resolved
SHIP IS MISSING 02 RADAR REFLECTORS (ONE FOR EACH LIFEBOAT), A VIOLATION OF SOLAS 74/78 III-41.8.30. LEGACY COMPONENT DESC: Radar Reflector
Navigation › Piloting/Steering
Issued 1 March 2003
Resolved
SHIP IS MISSING CHART #2605, A VIOLATION OF 33 CFR 164.33(a)(1). LEGACY COMPONENT DESC: Marine Charts
Personnel › Certificates/Documents/Licenses
Issued 1 March 2003
Resolved
BOTH SECOND OFFICERS ON BOARD DO NOT HAVE A VALID CYPRUS LICENSE OR APPLICATION FOR A CYPRUS LICENSE, A VIOLATION OF STCW-95. LEGACY COMPONENT DESC: License, Mate
Navigation › Piloting/Steering
Issued 1 March 2003
Resolved
MANEUVERING FACT SHEET POSTED ON THE BRIDGE DOES NOT CONTAIN INFORMATION FOR LOADED CONDITIONS, A VIOLATION OF 33 CFR 164.35(g)(6). ***TO BE ADDRESSED AT NEXT DRYDOCK IN 2004 LEGACY COMPONENT DESC: Maneuvering Information Fact Sheet
Fire Fighting › Firemans Outfit
Issued 1 March 2003
Resolved
SHIP HAS THREE FIREMAN'S OUTFITS WITHOUT FIRE RESISTANT GLOVES, A VIOLATION OF SOLAS 74/78 II-2/17-1.1.2. LEGACY COMPONENT DESC: Boots
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.