MAURY USCG vessel records
← All vessels

DESTINY

DESTINY is a 2003 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in May 2026, along with 18 deficiencies and 3 casualty investigations between 2008 and 2022.

Records from 2008 to 2026. Most recent: inspection, 11 May 2026.

Built
2003
Last inspected
11 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDP7903
609287
Flag
UNITED STATES
Maury page id
psix-609287

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)69.0 ft × 22.3 ft × 7.8 ft
Registered tonnagegross 80 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG & S BOATS · FREEPORT, FL, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 28 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Simplified, Gross Ton
64 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 24

11 May 2026 Administrative Inspection · Vessel Attendance · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8371668
7 January 2026 Damage Survey · Vessel Attendance · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8377894
6 November 2025 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8261347
12 March 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8091371
10 March 2025 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8092398
29 January 2024 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7851567
4 January 2024 Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7845058
2 November 2023 Administrative Inspection · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7819130
16 October 2023 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7809371
23 May 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7695431
18 April 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7434610
2 April 2022 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7473059
7 December 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7364038
16 March 2021 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7154958
7 April 2020 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6933098
4 February 2020 Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6902799
7 March 2019 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6636393
23 October 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570723
21 June 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6441413
29 March 2018 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6376548
15 June 2017 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6169416
16 June 2016 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5966229
17 May 2016 Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5876524
10 May 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5872628

Deficiency record · 18

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 January 2024 Resolved
Vessel restricted to Limited Coastwise route until interconnected fire detection system installed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 12 March 2025
Resolution: Verified installation of interconnected fire detection system. Conducted operational test, all sat.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 29 January 2024 Resolved
Installed VHF radios require GPS programming.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 January 2024 Resolved
Vessel required to have onboard hand bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 March 2025
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 May 2023 Resolved
Fixed fire extinguishing system is inoperable. Vessel required to have system operational and tested prior to operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2023
Resolution: Received service report from technician via owner certifying ready for service extinguishing system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2023 Resolved
Vessels fuel oil shut off valves remote pulls did not fully close valves. Shutoff valves, installed so as to close fuel flow in supply line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 October 2023
Resolution: Corrected.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 23 May 2023 Resolved
Vessel required to meet the requirements of stability letter issued to the vessel. Vessel has undergone significant weight changes with removal and replacement of interior furnishings and with the repowering of the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 4 January 2024
Resolution: Completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2022 Resolved
The inspected vessel maintains an active power-strip under the operating station. All electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Provide evidence of removal/repair.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 23 May 2022
Resolution: Received photograph from vessel owner of corrected deficiency.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 March 2021 Resolved
Conduct drills in accordance with 46 CFR 185. Required drills have not been conducted.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2021
Resolution: Observed vessel underway, conducted/discussed Man Ovbd, Fire, Flooding and Aboandon ship drills.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 16 March 2021 Resolved
Provide satisfactory life float in accordance with 46 CFR 180. Life float was beyond serviceability.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2021
Resolved 23 March 2021
Resolution: Life float renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2021 Resolved
Insepct fuel shut off valves in accordance with 46 CFR 182.455. Port and stbd fuel shut off valves were inoperative.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 8 December 2021
Resolution: Owner replaced both fuel valves, tested operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 March 2021 Resolved
Label upper deck passenger limit in accordance with 46 CFR 185.602. Upper deck passenger limit lable was missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 23 March 2021
Resolution: Upper deck passenger limit labeled.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 March 2021 Resolved
Inspect hull integrity in accordance with 46 CFR 176.610. Holes in way of rub rail were in port engine room side shell.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 23 March 2021
Resolution: Holes in port side shell plugged.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 March 2021 Resolved
Label circuits in accordancw with 46 CFR 183.220. Breaker panel circuits were not labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 23 March 2021
Resolution: Circuit breaker labeled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 March 2021 Resolved
Inspect hull integrity in accordance with 46 CFR 176.610. Glass over exposed core in gunwale, freeing ports, and engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2021
Resolved 8 December 2021
Resolution: Repaired and recoated.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 June 2017 Resolved
Replace life line
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 13 July 2017
Resolution: cleared
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 June 2017 Resolved
Replace shore power cable plug and wire
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 13 July 2017
Resolution: cleared
Electrical › Electric Generation Source (service) › Generator Cable
Issued 15 June 2017 Resolved
Repair wire on a generator
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 13 July 2017
Resolution: Cleared
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 15 June 2017 Resolved
Replace check valve on bilge system
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 13 July 2017
Resolution: cleared

Casualty record · 3

31 July 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3289681
16 June 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5966229
2 April 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7473059
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.