← All vessels
LT SAMUEL S COURSEN
Passenger (Inspected) · Passenger Ship class · Built 1950s · USCG Northeast District (CGD-NE) · Other hulls named LT SAMUEL S COURSEN
LT SAMUEL S COURSEN is a 1956 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2010, most recently in June 2025, along with 37 deficiencies, 3 operational controls and 1 casualty investigation in 2023.
Records from 2010 to 2025. Most recent: inspection, 24 June 2025.
- Built
- 1956
- Last inspected
- 24 June 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 37 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2023
Identity
1138191
WDN4367
609844
Flag
UNITED STATES
367549870
Maury page id
psix-609844
Inspections, by type
…with no type recorded3
Years with a record
10 calendar years (2010–2025)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)172.5 ft × 48.1 ft × 14.0 ft
Registered tonnagegross 761 / net 518
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOHN H MATHIS COMPANY · CAMDEN, NJ, UNITED STATES · built 1956
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it761 - Regulatory (Subpart C or D), Gross Ton
518 - Regulatory (Subpart C or D), Net Ton
518 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN4367MMSI 367549870 · active · compulsorily equipped · granted 7 October 2022, expires 7 October 2032
WDG5749MMSI 367549870 · cancelled · compulsorily equipped · granted 16 October 2012, cancelled 5 October 2022
WDC6095MMSI 367051230 · expired · compulsorily equipped · granted 21 June 2005, cancelled 22 August 2015
WDB3537MMSI 366888270 · expired · compulsorily equipped · granted 8 April 2003, cancelled 8 June 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 30
24 June 2025
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8155898
7 January 2025
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8042144
30 September 2024
Deficiency Check · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8008321
27 June 2024
Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7943873
26 February 2024
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7870457
31 January 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7858407
9 January 2024
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7845258
31 October 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7818003
31 October 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7818471
13 September 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7802214
25 August 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7778276
18 July 2023
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7750768
6 March 2023
Drydock Exam · Deficiency Check · Re-Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7646353
7 December 2022
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7604113
20 October 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7581020
29 September 2022
In-Service Inspection · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7568385
28 June 2022
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7489351
7 April 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7426260
7 March 2022
Deficiency Check · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7406980
9 December 2021
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7359604
27 September 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7321970
22 September 2021
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7317767
20 May 2021
Deficiency Check · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7201589
12 May 2021
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7195228
19 January 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7126888
16 September 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7059357
8 November 2019
MTSA Verification · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6852295
26 January 2017
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6077932
19 September 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4149517
24 September 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3856673
Deficiency record · 37
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 January 2025
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. Vsls Captain was unable to produce a valid medical certificate. Provide proof of a valid medical certificate for the Captain operating the vsl.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 January 2025
Resolved
Existing arrangements, materials, and facilities previously approved shall be considered satisfactory so long as they meet the minimum requirements of this paragraph, and they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Minor repairs and replacements may be made to the same standards as the original installation. Marine Inspector noticed a few sprinkler heads not working properly in Zone 1 and 2. Make repairs to all faulty sprinkler heads in accordance with manufacture specification prior to loading vehicle in Zones 1 and 2.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 January 2025
Resolved
The outlet at each fire hydrant must be provided with a cock or valve fitted in such a position that the fire hose may be removed while the fire main is under pressure. Marine Inspector noticed the valve on fire station #6 had a small leak after being fully closed. Make repairs to the fire hydrant valve in accordance with manufacture specifications.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 January 2025
Resolved
The fire main system must be operated and the pressure checked at the most remote and highest outlets. All firehose must be subjected to a test pressure equivalent to the maximum pressure to which they may be subjected in service, but not less than 100 p.s. i. Vsl was only able to test all fire hoses to 65 p.s.i. All hoses will be retested at next quarterly inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2024
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Lifebuoy retro tape, markings and plugs showed signs of deterioration.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 June 2024
Resolved
All life rafts must be labeled with the vessels name and official number as per regulation, vessel must label and replace missing caps on all life rafts.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 June 2024
Resolved
The painter line for 3 life rafts is missing the grommet at the entrance to the life raft, this must be replaced to keep weather out and help preserve the integrity of the life raft.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2024
Resolved
Vessel must keep all fire fighting gear ready and serviceable at all times, the hose on fire station failed during testing with CGMI due to outer cotton shell being dry rotted. Must replace this hose with new hose.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 27 June 2024
Resolved
The overhead suspended ceiling has come loose and is falling done IWO the port side female head, must re-attach the ceiling.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 27 June 2024
Resolved
The Captain ([name withheld] Lyon) could not produce his CG medical certificate during the inspection, provide proof of current medical certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 January 2024
Resolved
Found 4 life ring buoys with rotten lines. All 4 buoys were replaced while onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 December 2022
Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space (other than a paint locker). In the converter space there are flammables are not stored in the appropriate approved cabinets. Remove flammables or store in approved cabinets prior to operation with passengers. (Cleared while on-board)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 22 December 2022
Resolved
Clean out all deck drains on the vehicle deck as the clogged drains could possibly cause a stability issue and unsafe conditions for the passengers and crew onboard if the deck freezes. After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in stability letter. “FREEING PORTS: Deck freeing ports shall be maintained operable and completely unobstructed at all times.” (Cleared while onboard).
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 December 2022
Resolved
In the emergency battery space (above vehicle deck) determine what the pipe is used for, that has a rubber jumper hose and expansion clamp. Once the system is identified make the appropriate repairs to the satisfaction of the USCG Marine Inspector as the Inspector is not limited to inspections as deemed necessary to be assured of the safety and seaworthiness of the vessel. (By 01JAN23)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 December 2022
Resolved
The joinery and benches need to be put back in place prior to carrying passengers in way of the main deck windows. The Inspector is not limited to inspections as deemed necessary to be assured of the safety passengers of the vessel. (Cleared while on-board).
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 December 2022
Resolved
The vessel’s CO2 manual local controls need the correct labeling at #1 & #2 Cylinders (By 01JAN23)
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 22 December 2022
Resolved
The NYE #2 STBD steering pump has (2) lights burned out pwr available & running, must repair to like new condition. (By 01JAN23)
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 7 December 2022
Resolved
A survey ... shall be made every time an accident occurs ... which affects the safety of the vessel.
No survey was made after damage occured on 04OCT22.
46 CFR 71.40-1, 701c
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 December 2022
Resolved
The fire detection and alarm system must be capable of immediate operation.
Fire detection system was inoperable.
46 CFR 76.27-5(b)
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 7 December 2022
Resolved
MDE #1 low lube oil alarm switch has been modified from OEM and not working as designed, must replace this switch to OEM as original. (By 01JAN23)
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 28 June 2022
Resolved
The vessel operator must ensure that the means of access to restricted areas, including those where TWIC access is required, are controlled, during inspection, observed two clearly marked and identified restricted areas with improperly locked combination master locks. Witnessed vessel master, who is the vessel security officer, hold a meeting with crew, satisfying satisfactory response via security plan. Recommend further training on the proper securing of restricted areas.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 March 2022
Resolved
All officers on a vessel must have their licenses or officer endorsements conspicuously displayed. The crew did not have their original licenses on board, they keep them all ashore. If the crew prefer not to carry their official licenses (booklet) on board then a request should be made through the local OCMI allowing other arrangements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 March 2022
Resolved
CG Inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that it is in a satisfactory condition. Observed unusual noise and metal shaving from shaft present on both side of "Manhattan side" shaft bulkhead.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 March 2022
Resolved
When asked to examine the bridge log book/records there was nothing on-board to show. Such logs or records but must be kept available for review by a marine inspector for a period of 1 year after the date to which the records refer. In addition several of the future log sheets had been pre-signed. Due to the findings of the above security related items the USCG will be conducting unannounced security audits. Due to the findings of the above security related items the USCG will be conducting unannounced security audits.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 March 2022
Resolved
Observed excessive water leaking from the shaft seal at "Manhattan Side" Shaft.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 March 2022
Resolved
Observed excessive Lube Oil leaking from "Manhattan side
side" line shaft bearing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 March 2022
Resolved
Observed Hydraulic leak on the "GI Side" Hydraulic steering unit.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 March 2022
Resolved
Observed excessive rust and standing water on both rudder post.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2022
Resolved
Observed water leaking from main Fire Pump in the engine room.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 December 2021
Resolved
All fire detection systems shall be inspected annually. Provide fire service report from a fire servicing company.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2021
Resolved
Outfit vessel with an approved vessel response plan.
33 CFR 155.5015
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 9 December 2021
Resolved
Each embarkation ladder must be approved under approval series 160.117 or 160.017. Vessel embarkation ladders not serviceable, found cracks on several steps.
46 CFR 199.110(f)(1)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 December 2021
Resolved
Existing arrangments, materials and facilities previously approved shall be considered satisfactory. Found 3 sprinkler heads in zone 2 not operational. Correct prior to loading in zone 2.
46 CFR 76.23-90
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 May 2021
Resolved
Remove power strips from both pilot houses.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 May 2021
Resolved
Portable extinguishers must be from a mounted in marine grade bracket. Unmarked extinguisher, port side, GI end of vessel hanging from a hook must be properly stowed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 May 2021
Resolved
Portable fire extinguishers must be labeled IAW fire control plan and corresponding number on bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2019
Resolved
Remove out of service cable installation from radar room.
Casualty record · 1
31 October 2023Routine · role: Involved in a Marine Casualty · activity 7818471
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.