Records from 2017 to 2025. Most recent: inspection, 24 June 2025.
Inspection history · 28
24 June 2025
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8155898
7 January 2025
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8042144
30 September 2024
Deficiency Check · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8008321
27 June 2024
Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7943873
26 February 2024
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7870457
31 January 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7858407
9 January 2024
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7845258
31 October 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7818003
31 October 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7818471
13 September 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7802214
25 August 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7778276
18 July 2023
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7750768
6 March 2023
Drydock Exam · Deficiency Check · Re-Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7646353
7 December 2022
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7604113
20 October 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7581020
29 September 2022
In-Service Inspection · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7568385
28 June 2022
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7489351
7 April 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7426260
7 March 2022
Deficiency Check · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7406980
9 December 2021
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7359604
27 September 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7321970
22 September 2021
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7317767
20 May 2021
Deficiency Check · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7201589
12 May 2021
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7195228
19 January 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7126888
16 September 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7059357
8 November 2019
MTSA Verification · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6852295
26 January 2017
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6077932
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 January 2025
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. Vsls Captain was unable to produce a valid medical certificate. Provide proof of a valid medical certificate for the Captain operating the vsl.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2025
Resolution: Master provided medical certificate.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 January 2025
Resolved
Existing arrangements, materials, and facilities previously approved shall be considered satisfactory so long as they meet the minimum requirements of this paragraph, and they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Minor repairs and replacements may be made to the same standards as the original installation. Marine Inspector noticed a few sprinkler heads not working properly in Zone 1 and 2. Make repairs to all faulty sprinkler heads in accordance with manufacture specification prior to loading vehicle in Zones 1 and 2.
Action required: 705 - Other - as specified
Resolved 7 January 2025
Resolution: Master sent an email attesting to all sprinkler heads operating as designed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 January 2025
Resolved
The outlet at each fire hydrant must be provided with a cock or valve fitted in such a position that the fire hose may be removed while the fire main is under pressure. Marine Inspector noticed the valve on fire station #6 had a small leak after being fully closed. Make repairs to the fire hydrant valve in accordance with manufacture specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 18 January 2025
Resolution: Received objective evidence via photograph the fire station valve was repaired, sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 January 2025
Resolved
The fire main system must be operated and the pressure checked at the most remote and highest outlets. All firehose must be subjected to a test pressure equivalent to the maximum pressure to which they may be subjected in service, but not less than 100 p.s. i. Vsl was only able to test all fire hoses to 65 p.s.i. All hoses will be retested at next quarterly inspection.
Action required: 705 - Other - as specified
Resolved 24 June 2025
Resolution: Received video evidence of 01 fire hose energized and fire pump maintaining adequate pressure, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2024
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Lifebuoy retro tape, markings and plugs showed signs of deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2024
Resolved 10 October 2024
Resolution: Ring life buoys properly serviced or replaced and marked accordingly.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 June 2024
Resolved
All life rafts must be labeled with the vessels name and official number as per regulation, vessel must label and replace missing caps on all life rafts.
Action required: 705 - Other - as specified
Resolved 1 July 2024
Resolution: Missing caps replaced and name of vessel entered on log/paper.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 June 2024
Resolved
The painter line for 3 life rafts is missing the grommet at the entrance to the life raft, this must be replaced to keep weather out and help preserve the integrity of the life raft.
Action required: 705 - Other - as specified
Resolved 1 July 2024
Resolution: All grommets replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2024
Resolved
Vessel must keep all fire fighting gear ready and serviceable at all times, the hose on fire station failed during testing with CGMI due to outer cotton shell being dry rotted. Must replace this hose with new hose.
Action required: 705 - Other - as specified
Resolved 1 July 2024
Resolution: Hose had been replaced
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 27 June 2024
Resolved
The overhead suspended ceiling has come loose and is falling done IWO the port side female head, must re-attach the ceiling.
Action required: 705 - Other - as specified
Resolved 1 July 2024
Resolution: Ceiling has been fixed.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 27 June 2024
Resolved
The Captain ([name withheld] Lyon) could not produce his CG medical certificate during the inspection, provide proof of current medical certificate.
Action required: 705 - Other - as specified
Resolved 1 July 2024
Resolution: Med card provided.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 January 2024
Resolved
Found 4 life ring buoys with rotten lines. All 4 buoys were replaced while onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 January 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 December 2022
Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space (other than a paint locker). In the converter space there are flammables are not stored in the appropriate approved cabinets. Remove flammables or store in approved cabinets prior to operation with passengers. (Cleared while on-board)
Action required: 10 - Deficiency Rectified
Due 22 December 2022
Resolved 22 December 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 22 December 2022
Resolved
Clean out all deck drains on the vehicle deck as the clogged drains could possibly cause a stability issue and unsafe conditions for the passengers and crew onboard if the deck freezes. After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in stability letter. “FREEING PORTS: Deck freeing ports shall be maintained operable and completely unobstructed at all times.” (Cleared while onboard).
Action required: 10 - Deficiency Rectified
Due 22 December 2022
Resolved 22 December 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 December 2022
Resolved
In the emergency battery space (above vehicle deck) determine what the pipe is used for, that has a rubber jumper hose and expansion clamp. Once the system is identified make the appropriate repairs to the satisfaction of the USCG Marine Inspector as the Inspector is not limited to inspections as deemed necessary to be assured of the safety and seaworthiness of the vessel. (By 01JAN23)
Action required: 705 - Other - as specified
Due 1 January 2023
Resolved 29 December 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 December 2022
Resolved
The joinery and benches need to be put back in place prior to carrying passengers in way of the main deck windows. The Inspector is not limited to inspections as deemed necessary to be assured of the safety passengers of the vessel. (Cleared while on-board).
Action required: 10 - Deficiency Rectified
Due 22 December 2022
Resolved 22 December 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 December 2022
Resolved
The vessel’s CO2 manual local controls need the correct labeling at #1 & #2 Cylinders (By 01JAN23)
Action required: 705 - Other - as specified
Due 1 January 2023
Resolved 27 December 2022
Resolution: Correct label is now installed.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 22 December 2022
Resolved
The NYE #2 STBD steering pump has (2) lights burned out pwr available & running, must repair to like new condition. (By 01JAN23)
Action required: 705 - Other - as specified
Due 1 January 2023
Resolved 27 December 2022
Resolution: Lights are fixed
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 7 December 2022
Resolved
A survey ... shall be made every time an accident occurs ... which affects the safety of the vessel.
No survey was made after damage occured on 04OCT22.
46 CFR 71.40-1, 701c
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 December 2022
Resolution: Damage looked at by MI and verbal agreement made to repair as discussed
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 December 2022
Resolved
The fire detection and alarm system must be capable of immediate operation.
Fire detection system was inoperable.
46 CFR 76.27-5(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2022
Resolution: New detection heads installed and tested, all trouble alarms cleared.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 7 December 2022
Resolved
MDE #1 low lube oil alarm switch has been modified from OEM and not working as designed, must replace this switch to OEM as original. (By 01JAN23)
Action required: 705 - Other - as specified
Due 1 January 2023
Resolved 29 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 28 June 2022
Resolved
The vessel operator must ensure that the means of access to restricted areas, including those where TWIC access is required, are controlled, during inspection, observed two clearly marked and identified restricted areas with improperly locked combination master locks. Witnessed vessel master, who is the vessel security officer, hold a meeting with crew, satisfying satisfactory response via security plan. Recommend further training on the proper securing of restricted areas.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 June 2022
Resolved 28 June 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 March 2022
Resolved
All officers on a vessel must have their licenses or officer endorsements conspicuously displayed. The crew did not have their original licenses on board, they keep them all ashore. If the crew prefer not to carry their official licenses (booklet) on board then a request should be made through the local OCMI allowing other arrangements.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2022
Resolution: Received request to maintain copies onboard and original in locker room GI side
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 March 2022
Resolved
CG Inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that it is in a satisfactory condition. Observed unusual noise and metal shaving from shaft present on both side of "Manhattan side" shaft bulkhead.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2022
Resolution: No shaft noise was observed underway with the shaft operating multiple speeds in both directions.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 March 2022
Resolved
When asked to examine the bridge log book/records there was nothing on-board to show. Such logs or records but must be kept available for review by a marine inspector for a period of 1 year after the date to which the records refer. In addition several of the future log sheets had been pre-signed. Due to the findings of the above security related items the USCG will be conducting unannounced security audits. Due to the findings of the above security related items the USCG will be conducting unannounced security audits.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 March 2022
Resolution: Originals onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 March 2022
Resolved
Observed excessive water leaking from the shaft seal at "Manhattan Side" Shaft.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2022
Resolution: Less water was observed at the shaft seal after the [name withheld] adjustments were made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 March 2022
Resolved
Observed excessive Lube Oil leaking from "Manhattan side
side" line shaft bearing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2022
Resolution: Less oil was observed at the shaft line bearing. NYW and USCG will continue to monitor on subsequent Quarterly inspections to assess if further action is required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 March 2022
Resolved
Observed Hydraulic leak on the "GI Side" Hydraulic steering unit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2022
Resolution: Hydraulic leak was repaired, however NYW will have system piping replaced during the vessel’s next DD/ISE period. NYW will provide USCG drawings to ensure the system is properly rebuilt.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 March 2022
Resolved
Observed excessive rust and standing water on both rudder post.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2022
Resolution: Both rudder post’s packing seals were replaced and no leakage was observed. During the next DD/ISE period, NYW will have both rudder post pedestal frames replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2022
Resolved
Observed water leaking from main Fire Pump in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 December 2021
Resolved
All fire detection systems shall be inspected annually. Provide fire service report from a fire servicing company.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2021
Resolution: Company provided fire servicing report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2021
Resolved
Outfit vessel with an approved vessel response plan.
33 CFR 155.5015
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 13 January 2022
Resolution: Vessel has an approved VRP
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 9 December 2021
Resolved
Each embarkation ladder must be approved under approval series 160.117 or 160.017. Vessel embarkation ladders not serviceable, found cracks on several steps.
46 CFR 199.110(f)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2021
Resolution: Vessel replaced embarkation ladders
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 December 2021
Resolved
Existing arrangments, materials and facilities previously approved shall be considered satisfactory. Found 3 sprinkler heads in zone 2 not operational. Correct prior to loading in zone 2.
46 CFR 76.23-90
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2021
Resolution: Witnessed operation of zone 2 sprinkler system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 May 2021
Resolved
Remove power strips from both pilot houses.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 1 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 May 2021
Resolved
Portable extinguishers must be from a mounted in marine grade bracket. Unmarked extinguisher, port side, GI end of vessel hanging from a hook must be properly stowed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 1 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 May 2021
Resolved
Portable fire extinguishers must be labeled IAW fire control plan and corresponding number on bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2021
Resolved 1 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2019
Resolved
Remove out of service cable installation from radar room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2019
Resolved 3 December 2019