← All vessels
ST CROIX
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Northeast District (CGD-NE) · Other hulls named ST CROIX
ST CROIX is a 2003 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2003, most recently in November 2025, along with 27 deficiencies and 2 casualty investigations between 2021 and 2024.
Records from 2003 to 2025. Most recent: inspection, 12 November 2025.
- Built
- 2003
- Last inspected
- 12 November 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 27 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2021–2024
Identity
1138226
WDJ8419
609945
Flag
UNITED STATES
368016180
Maury page id
psix-609945
Inspections, by type
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 15.0 ft × 4.4 ft
Registered tonnagegross 17 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderR.P. BOATSHOP · STEUBEN, ME, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPORTLAND, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
14 - Simplified, Net Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ8419MMSI 368016180 · active · compulsorily equipped · granted 13 December 2017, expires 13 December 2027
WDD9820MMSI 367316750 · expired · compulsorily equipped · granted 6 October 2007, cancelled 9 December 2017
WDB4296MMSI 366896920 · expired · compulsorily equipped · granted 10 June 2003, cancelled 10 August 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 28
12 November 2025
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8265732
22 November 2024
COI Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8042074
1 August 2024
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7974633
6 November 2023
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7820901
10 November 2022
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7593853
10 November 2021
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7348846
10 June 2021
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7221190
4 June 2021
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7231409
18 November 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7180825
16 September 2020
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7059014
4 November 2019
COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6848854
6 November 2018
Administrative Inspection · DAPI Audit · Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6575888
25 October 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6295046
4 November 2016
Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6059936
27 October 2015
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5758187
15 October 2014
Annual Inspection · COI Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5005676
17 July 2012
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4382694
25 August 2011
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4124928
9 April 2009
Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3449250
10 June 2008
COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3222101
27 June 2007
Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2980591
18 April 2007
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2909347
29 August 2006
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2762397
1 August 2005
Re-Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2448555
9 May 2005
Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2352848
2 September 2004
Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2189340
29 July 2003
Deficiency Check
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1875229
13 March 2003
Simplified Stability Test · Plan Review "T" Boat · Construction Oversight · Initial Certification
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1756757
Deficiency record · 27
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 November 2025
Resolved
The vessel's FCC Safety Radio Certficate is expired.
Engineering › Bilge Water Management System › Pump
Issued 4 November 2016
Resolved
Bilge pump not operating during inspection. Owner fixed pump shortly after departing vessel.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 15 October 2014
Resolved
Prior to operations inspector must attend vessel to ensure it meets conditions of current COI.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 27 June 2007
Resolved
Provide updated Certificate of Documentation. [name withheld] has just purchased vessel from [name withheld]; paperwork has been submitted to National Vessel Documentation Center for change of ownership.
Fire Fighting › Fire Bucket › Quantity
Issued 29 August 2006
Resolved
Provide 2 additional fire buckets.
Documentation › Certificates/Documents › FCC SSL
Issued 29 August 2006
Resolved
Provide valid FCC Safety Certificate.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 August 2006
Resolved
Prove proper operation of high bilge alarm in lazaret.
Communications › Radio Communications › VHF Radiotelephone
Issued 29 August 2006
Resolved
Properly mount VHF radio.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 29 August 2006
Resolved
Tighten lifelines.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 August 2006
Resolved
Prove proper operation of fixed fire system machinery shutdown.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 29 August 2006
Resolved
System is overpressurized . Ensure system is at mormal operating pressure.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 1 August 2005
Resolved
SHOW EVIDENCE OF FIRST AID/CPR TRAINING FOR MINIMUM OF %50 OF CREW
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 August 2005
Resolved
MAKE OPERABLE STARBOARD AND ANCHOR LIGHT
Communications › Radio Communications › EPIRB
Issued 1 August 2005
Resolved
SHOW EVIDENCE OF CORRECT EPIRB REGISTRATION
Communications › Radio Communications › EPIRB
Issued 1 August 2005
Resolved
REPLACE EPIRB HYDROSTATIC RELEASE
Personnel › Training › First Aid/CPR
Issued 2 September 2004
Resolved
SHOW EVIDENCE THAT AT LEAST 50% OF CREW HAS FIRST AID/CPR TRAINING.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 2 September 2004
Resolved
FASTEN REAR BENCH SECURELY TO DECK.
Engineering › Bilge Water Management System › Not Operational
Issued 2 September 2004
Resolved
CLEAN BILGES / REMOVE OVERFLOW ANTIFREEZE.
Engineering › Steering Gear System › Power Unit
Issued 2 September 2004
Resolved
CORRECT HYDROSLAVE LEAK IN FORWARD COMPARTMENT.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 September 2004
Resolved
SERVICE ENGINE VENT CLOSURES.
Lifesaving › Buoyant Apparatus › Not on Board
Issued 13 March 2003
Resolved
PROVIDE AND PROPERLY INSTALL PRIMARY LIFESAVING EQUIPMENT. VESSEL IS RESTRICTED TO LESS THAN 1 MILE FROM SHORE UNTIL THIS REQUIREMENT IS CLEARED.
Communications › Alarms/Indicators
Issued 13 March 2003
Resolved
PROVIDE PROOF OF EPIRB REGISTRATION. VESSEL IS RESTRICTED TO LESS THAN 3 MILES FROM SHORE UNTIL THIS REQUIREMENT IS CLEARED.
Electrical › Electrical Distribution System (service)
Issued 13 March 2003
Resolved
INSTALL OVER CURRENT PROTECTION IN CIRCUIT BETWWEN HOUSE BATTERY AND OPERATORS CONSOLE FUSE STRIP. LEGACY COMPONENT DESC: Overcurrent Device
Operations/Management › Navigation Safety
Issued 13 March 2003
Resolved
MAKE MASTHEAD LIGHT A MORE PERMANENT INSTALLATION. LEGACY COMPONENT DESC: Navigation Underway, General
Engineering › Shafting/Propeller Arrangements
Issued 13 March 2003
Resolved
PROVIDE AND INSTALL PROPER SIZE PACKING IN PROPELLER SHAFT STUFFING BOX. LEGACY COMPONENT DESC: Stern Gland
Operations/Management › Drug and Alcohol Testing
Issued 13 March 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Navigation Safety
Issued 13 March 2003
Resolved
INSTALL AN ANCHOR LIGHT ON VESSEL. LEGACY COMPONENT DESC: Navigation Underway, General
Casualty record · 2
4 June 2021Routine · role: Involved in a Marine Casualty · activity 7231409
1 August 2024Routine · role: Involved in a Marine Casualty · activity 7974633
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.