MAURY USCG vessel records Sign in
← All vessels

BOB PALMER

BOB PALMER is a 2003 mobile offshore drilling unit. The Coast Guard has recorded 15 inspections since 2001, most recently in September 2010, along with 11 deficiencies and 2 casualty investigations between 2006 and 2009.

Records from 2001 to 2010. Most recent: inspection, 20 September 2010.

Built
2003
Last inspected
20 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB3387
610021
Flag
UNITED STATES
—
Maury page id
psix-610021

Inspections, by type

…with no type recorded3
Years with a record 9 calendar years (2001–2010)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5607 - Convention (Subpart B), Net Ton
18692 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

20 September 2010 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3853683
2 September 2010 Deficiency Check · ACP Annual Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3839638
25 December 2009 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3655264
7 May 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3469559
4 May 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3467264
26 August 2008 ACP COI Oversight
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3308994
16 October 2007 ACP COI Oversight
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3081246
1 March 2007 ACP COI Oversight
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2799889
10 August 2006 Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2743101
4 November 2005 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2527546
1 October 2004 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2221708
13 January 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2027634
12 January 2004 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1982368
22 May 2003 Initial Certification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1876988
15 October 2001 Construction Oversight
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1813250

Deficiency record · 11

Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 2 September 2010 Resolved
Service fire curtains for galley serving line and scullery window.
Action required: 705 - Other - as specified
Due 2 October 2010
Resolved 5 September 2010
Resolution: Replaced blown fuse in the fire and gas panel for the fire curtain and scullery window. Functioned and brought into working order. Cleared by MSU Port Arthur.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 2 September 2010 Resolved
Service fire door between scullery and galley.
Action required: 705 - Other - as specified
Due 2 October 2010
Resolved 5 September 2010
Resolution: Removed damaged hinge and replaced with new one. Functioned door to ensure proper closure. Cleared by MSU Port Arthur.
Electrical › Electric Supply System (service) › Cable
Issued 2 September 2010 Resolved
Install permenent ties on wiring above door of port side emergency generator room. Current ties are plastic.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 October 2010
Resolved 5 September 2010
Resolution: Removed plastic ties and replaced them with metal tie bands. Cleared by MSU Port Arthur.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 2 September 2010 Resolved
Mark fuel and oil transfer hoses in accordance with 33 CFR 154.500.
Action required: 705 - Other - as specified
Due 2 October 2010
Resolved 5 September 2010
Resolution: Marked hoses using a stencil and spray paint with the information required in part 154.500. Each hose was marked with the following: working pressure, date manufactured, date of last test, and "oil service." Cleared by MSU Port Arthur.
Engineering › Compressed Air System (control) › Piping
Issued 2 September 2010 Resolved
Replace stainless steel air control line to remote valve for foam monitor at forward most position on bow.
Action required: 705 - Other - as specified
Due 2 October 2010
Resolved 20 September 2010
Resolution: Removed bad control line and installed new. Functioned and brought into working order.
Communications › Alarms/Indicators › General Alarm
Issued 26 August 2008 Resolved
Prove proper operation of general alarm beacon in the engine room
Condition: Unknown
Due 10 September 2008
Resolved 9 September 2008
Resolution: Received verification that the beacon is functioning properly.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 26 August 2008 Resolved
Provide proof of proper agent quantity in the rigs CO2 fire extinguishers. No weights were provided on the third party servicing reports.
Condition: Improper/Lack of Maintenance
Due 10 September 2008
Resolved 27 September 2008
Resolution: OIM Provided document with recorded weights.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 31 October 2007 Resolved
Conduct annual review of SOPEP IAW 33 CFR 151.28(a) and provide copy of review letter to the satisfaction of the USCG marine inspector.
Due 30 November 2007
Resolved 13 November 2007
Resolution: Received documentation verifying the SOPEP was reviewed on 12 Nov 07
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 October 2007 Resolved
Repair or replace the forward boundary door of the Emergency Generator Room (bottom lip is rusted out) in order to maintain the Class A bulkhead boundary IAW 46 CFR 108.139 to the satisfaction of the attending marine surveyor.
Condition: Unknown
Due 31 October 2008
Resolved 2 November 2007
Resolution: Replaced fire door.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 October 2007 Resolved
Replace shattered overhead safety glass on the driller's shack to the satisfaction of the USCG marine inspector.
Due 30 November 2007
Resolved 26 September 2008
Resolution: [name withheld] verified the glass had been renewed.
Electrical
Issued 18 August 2003 Resolved
COMPLETE ALL OUTSTANDING RECOMMENDATIONS OF CLASS IN THE SPECIFIED TIMEFRAME.
Action required: 705 - Other - as specified
Due 22 February 2004
Resolved 12 January 2004

Casualty record · 2

20 November 2006Routine · role: Involved in a Marine Investigation (non-casualty) · 1 dead · activity 2825935
14 October 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3618981
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.