MAURY USCG vessel records Sign in
← All vessels

CARIBBEAN EXPRESS

CARIBBEAN EXPRESS is a 1976 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 2003, most recently in March 2010, along with 59 deficiencies — 1 with no resolution recorded — and 12 operational controls.

Records from 2003 to 2010. Most recent: inspection, 23 March 2010.

Built
1976
Last inspected
23 March 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7400778 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
610067
Flag
PANAMA
—
Maury page id
psix-610067

Inspections, by type

…with no type recorded21
Years with a record 8 calendar years (2003–2010)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it8177 - Convention (Subpart B), Net Ton
3166 - Dead Weight, Ton
19292 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 65

23 March 2010 COC-CVE Annual
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3701019
13 January 2010 ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3663042
10 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3661520
8 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3660698
25 March 2009 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3440423
23 January 2009 COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3398727
23 October 2008 COC-CVE Quarterly · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3350235
10 September 2008 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3325301
20 August 2008 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3315925
6 August 2008 NPV Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3291134
30 July 2008 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3287085
18 July 2008 NPV Safety Exam · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3272345
14 April 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3184015
28 March 2008 Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3172391
11 February 2008 NPV Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3146213
24 December 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3120399
30 October 2007 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3090339
4 October 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3072554
3 October 2007 COC-CVE Quarterly · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3071831
24 September 2007 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3065119
24 September 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3067351
26 July 2007 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3007665
18 June 2007 ISPS II Exam · STCW 95 Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2965602
28 March 2007 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2897335
17 October 2006 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2802174
13 October 2006 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2799875
25 September 2006 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2786644
28 August 2006 Random ISPS/MTSA-No PSC · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2762870
25 August 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2759634
17 August 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2751050
16 August 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2749504
16 August 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2749881
7 August 2006 Random ISPS/MTSA/PSC · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2739604
6 August 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2737087
20 July 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2718846
10 March 2006 COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2600040
13 January 2006 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2566643
10 January 2006 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2563877
4 November 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2528353
17 October 2005 COC-CVE Quarterly · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2516872
19 September 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2497827
5 August 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2464512
30 July 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2445063
8 July 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2419796
8 July 2005 Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2430528
17 May 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2360052
29 April 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2217536
14 April 2005 COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2333754
5 April 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2326722
24 October 2004 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2228836
7 October 2004 COC-CVE Quarterly
Type not classified · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2215646
3 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2185632
4 August 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2185248
3 August 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2155047
1 July 2004 ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2117647
19 April 2004 Certificate of Compliance · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2052715
18 November 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1949737
18 October 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1941856
18 October 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1944932
15 October 2003 Quarterly Examination · MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1928083
10 September 2003 MARPOL Annex V Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1903453
15 August 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1881990
13 April 2003 MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1771604
10 April 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1771599
19 March 2003 Control Verification
Physical examination · Activities Europe · Activity 1766179

Deficiency record · 59

Personnel › Certificates/Documents/Licenses › STCW Certificate, OIC of Navigational Watch
Issued 23 January 2009 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 3 March 2009
Resolution: This deck officer is no longer serving as a crew member on board.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 30 July 2008 Resolved
Develop shipboard procedure and crew instructions for proper testing and operation of piston fire/bilge pump (a designated fire pump per ship's fire control plan). Procedures and instructions should... include easy to understand diagrams and written instructions in ship's official language which would enable the engineers to efficiently energize the fire main with this pump.
Action required: 705 - Other - as specified
Resolved 6 August 2008
Resolution: USCG Boarding Team verified diagram and instructions are now on board.
Fire Fighting › Fire Pumps › Pressure
Issued 18 July 2008 Resolved
Vessel is required three fire pumps; only two are operable. Others inoperable upon testing and admission by shief engineer. Ship is detained until it can comply with applicable SOLAS rules concerning fire protection appliances. Class/Flag surveyor must attest to wuitability of any alternate/temporary arrangement, to be reviewed by COTP prior to detention being lifted.
Action required: 705 - Other - as specified
Resolved 18 July 2008
Resolution: Flag waiver permiting vessel to operate temporarilly with two vice three fire pumps, repair procedure in place to provide thre pumps by next U.S. call. COTP lifted detention.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 July 2008 Resolved
Class.Flag is requested to verify proper operation of ship's OWS equipment. Ship must provide adequate procedures for regular testing and maintenance of system, as currently there are none.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2008
Resolution: Flag surveyor attests that system is in disrepair, issued 4-week requrement to repair or replace.
Construction/Loadline › Penetrations › Valve Flange
Issued 18 July 2008 Resolved
Overboard sea valve for OWS does not close 100%. Valve is below waterline by > 1 mtr, allows 10-20 gpm backflow to secondary sea cock. Action: Repair/replace sea valve to provide proper watertight seal fo Flag/Class satisfaction.
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 30 July 2008
Resolution: Renewed.
Engineering › Bilge Water Management System › Pump
Issued 18 July 2008 Resolved
Affect repairs to "piston bilge/fire" pump - currently inoperable.
Action required: 705 - Other - as specified
Due 18 August 2008
Resolved 30 July 2008
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 18 July 2008 Resolved
Properly dispose of oily bilge waste currently in bilge wells and in portable containers scattered about engine room. Provided proof of proper disposal to attending USCG PSCO.
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 30 July 2008
Resolution: Bilges wells and holding tanks examined. Records verified to disposal receipts.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 March 2008 Resolved
OWS content meter and alarm not functioning properly. Ch. Eng. unable to demonstrate proper operation. OWS must be demonstrated to operate properly prior to vessel's departure from port.
Action required: 705 - Other - as specified
Resolved 29 March 2008
Resolution: After affecting minor repairs to OCM sending unit and filter tank sensors, OWS was demonstrated to operate properly.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 3 October 2007 Resolved
Fire screen door indicator panel must display proper "closed" position for all fire screen doors. On the day of inspection, fire screen doors # 30, 38, 52, 56, 59, 68, and 94 did not indicate that they were closed on indicator panel. SOLAS 74/78 (2004 ed) II-2/9.4 50a/b
Action required: 705 - Other - as specified
Due 3 November 2007
Resolved 30 October 2007
Resolution: Received Class report attesting door''s indicators have been adjusted.//JAR
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 3 October 2007 Resolved
Many life jackets were found with expired or dysfunctional lights. Fix or replace. SOLAS 74/78 (2004 ed) 3/22.3.1 50a/b
Action required: 705 - Other - as specified
Due 3 November 2007
Resolved 30 October 2007
Resolution: Received Class report attesting that 350 lights were replaced.//JAR
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 3 October 2007 Resolved
Section valves for hi-fog system did not properly indicate activation [at main control panel] during loss of pressure. Demonstrate proper operation of hi-fog system. SOLAS 74/78 (2004 ed) II-2/10.6 50a/b/c
Action required: 705 - Other - as specified
Due 3 November 2007
Resolved 30 October 2007
Resolution: Received Class report attesting system adjusted and corrected.//JAR
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 24 September 2007 Resolved
Vessel's total passengers on board allowance (per its valid Certificate of Compliance) is reduced by 60 to 1028 passengers until all lifeboats and launching arrangements have been determined to be repaired and operating properly to the satisfaction of Class or Flag Administration.
Condition: Design Flaw
Due 24 October 2007
Resolved 30 October 2007
Resolution: Received class report attesting lifeboat and equipment have been repaired.//JAR
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 24 September 2007 Resolved
Detrmined root cause of #2 lifeboat falls failure and corrective action plan as it pertains to #2 lifeboat launching arrangements, as well as all othr lifeboats and their launching arrangements, per ship's Safety management system and provisions of the ISM code.
Due 24 October 2007
Resolved 30 October 2007
Resolution: Received Class report attesting the root cause for the incident.//JAR
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 18 June 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2007
Resolved 18 June 2007
Resolution: Recieved Flag State maritime surveyor attesting received of applications for endorsement.
Lifesaving › Inflatable Liferafts › Servicing
Issued 28 March 2007 Resolved
Conduct launch & inflation of one davit launched liferaft in presence of US Coast Guard Marine Inspector. SOLAS 74/78 (2004 ed) III/30 40c
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 2 April 2007
Fire Fighting › Means of Escape › Emergency Lighting
Issued 28 March 2007 Resolved
Affect repairs to ship's low level lighting. Several individual light elements are extinguished, including one section on deck 7, aft, near vending machines. SOLAS 74/78 (2004 ed) II-2/13.3.2 50a/c
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 28 March 2007 Resolved
Affect repairs to STBD lifeboat #5 (currently no propulsion, broken rudder/tiller assembly). SOLAS 60 III/27 50c
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Lifesaving › Lifeboat › Capacity
Issued 28 March 2007 Resolved
Total persons onboard reduced to 1099 (1003 passengers) due to inoperable lifeboat: STBD #5, see Certificate of Compliance dated 28MAR07. SOLAS 74/78 (2004 ed) III/21 50c
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 2 April 2007
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 28 March 2007 Resolved
Amend muster list and emergency instructions to include crewmember assigned to direct passengers to escape routes in "Commodore's Class" accommodation passageway - specifically, with regards to AFT escape route (kick plates through cabin doors) SOLAS 74/78 (2004 ed) III/37 40a
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 2 April 2007
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 28 March 2007 Resolved
Provide fire fighter outfits per ship's Passenger Ship Safety Certificate: Currently 2 fire outfits (for Bravo Team) have holes and rips in the coats & pants. SOLAS 74/78 (2004 ed) II-2/10.10 40a/c
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 2 April 2007
Deck/Cargo › Mooring/Anchoring › Winch
Issued 25 September 2006 Resolved
Provide functioning anchor windlass motors for pt. and stbd. windlass systems. Ensure proper installation of eachaccording to ship's drawings and manufacturer's instructions. Notify flag rep of repairs.
Action required: 705 - Other - as specified
Due 29 October 2006
Resolved 12 October 2006
Resolution: Flag rep (class) report on file.
Construction/Loadline › Hull › Side Shell
Issued 28 August 2006 Resolved
Class Society to inspect and provide report of hull damage to the portside aft and the ramp attesting hull is in satisfactory condition and ramp is safe. Hull suffered surface damage at cornerpost; ramp had two (2) flaps damaged.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 September 2006
Resolved 4 September 2006
Resolution: Received class report attesting to hull and ramp in satisfactory conditions.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 25 August 2006 Resolved
Vessel failed to submitted proper ANOA.
Due 25 August 2006
Resolved 25 August 2006
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 7 August 2006 Resolved
Smoke detector #0123 (deck7) not functioning properly. SOLAS 60/II-C1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2006
Resolution: Detector repaired and tested sat.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 7 August 2006 Resolved
Fire screen door #93B does not close properly at local control point. Fire screen door #21 does not register as closed at control room panel. These doors are located within portion of the ship under SOLAS 74 due to major modifications after orig build. SOLAS 74/II-2/3.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2006
Resolution: Doors repaired and tested sat.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 7 August 2006 Resolved
Provide certification that the new carpet material meets fire retardant standarts of Fire Test Procedure Code Annex 1, part 7 and IMO Res A.687(17).
Due 21 August 2006
Resolved 29 August 2006
Resolution: viewed a copy of the certificate from the supplier and installer stating that the carpets installed on the caribbean express meets fire retardant standarts of Fire Test Procedure Code Annex 1, part 7 and IMO Res A.687(17).
Fire Fighting › Automatic Sprinkler System › Stop Valves
Issued 7 August 2006 Resolved
Sprinkler suction valves (car deck) must be kept open and in line so that crewmember does not have to enter car deck to manually open valves in order to activate sprinkler system.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2006
Resolution: Valves open and labeled to remain open at all times.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 7 August 2006 Resolved
Provide a Ballast Water Management plan specific to vessel as per 33CFR 151 subpart D.
Condition: Unknown
Due 7 September 2006
Resolved 25 September 2006
Resolution: Reviewed new BWM plan. Meets scope of regulation. Interviewed BWM Officer (staff capt.) he is aware of his duties prescribed in the plan, is submitting BW reports to NBIC.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 7 August 2006 Resolved
Provide evidence that the mandatory ballast water report form was submitted to NBIC.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2006
Resolution: Master reported that form was sent to NBIC. Tried to fax receipt to this office with negres.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 20 July 2006 Resolved
VESSEL DIDN'T COMPLY WITH PROPER ANOA TIME REQUIREMENTS.
Due 29 August 2006
Resolved 29 August 2006
Fire Fighting › Fire Hydrants › Material
Issued 10 March 2006 Resolved
Spanner wrenches missing at all fire stations throughout the engine room.
Due 31 March 2006
Resolved 31 March 2006
Fire Fighting › Means of Escape › Emergency Lighting
Issued 10 March 2006 Resolved
Lighting in the emergency escape trunks in the E/R not working.
Due 31 March 2006
Resolved 31 March 2006
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 10 March 2006 Resolved
During testing of the Marriot High Fog system, section valve S9, a 3 ft piece of piping falied at the fitting when the pump enaged.
Condition: Unknown
Due 31 March 2006
Resolved 31 March 2006
Resolution: Piping and compression fitting replaced, system re-tested w/ sat results.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 10 March 2006 Resolved
LB #2 & #4, PORT SIDE UPPER TILLER BRACKETS LOOSE.
Due 31 March 2006
Resolved 31 March 2006
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 10 January 2006 Resolved
Electric motor for Port side anchor inop. Provide Class or Flag attestation when repaired, or have attending USCG MI inspect motor.
Action required: 705 - Other - as specified
Resolved 13 January 2006
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 17 October 2005 Resolved
Exhaust lagging for #4 generator is separated and exhaust piping is exposed.
Condition: Design Flaw
Due 31 October 2005
Resolved 17 October 2005
Resolution: Corrected by the end of this inspection.
Fire Fighting › Portable CO2 Fire Extinguisher › Valve
Issued 17 October 2005 Resolved
Wheel for portable CO2 fire exitnguisher near fire station #135 in the engine room is broken.
Condition: Damaged By Earlier Event
Due 31 October 2005
Resolved 4 November 2005
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 October 2005 Resolved
Rudder angle indicator marks in the steering gear room are illegible for the starboard side.
Condition: Improper/Lack of Maintenance
Due 31 October 2005
Resolved 17 October 2005
Resolution: Corrected by the end of this inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 October 2005 Resolved
Provide procedures for administering narcotics to passengers and crewmembers.
Condition: Unknown
Due 31 October 2005
Resolved 4 November 2005
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 17 October 2005 Resolved
Ensure that fire screen doors (sliding) # 3,9,41,51,66,67,70, 89 latch when closed.
Condition: Improper/Lack of Maintenance
Due 31 October 2005
Resolved 4 November 2005
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 17 October 2005 Resolved
Verify that all liferaft's weaklinks are properly installed to each liferaft, port and starboard.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2005
Resolution: Corrected and verified by [name withheld] prior to departure from vessel.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 October 2005 Resolved
Low level lightning on the #5 deck near the stairway (10FT) not working.
Due 31 October 2005
Resolved 17 October 2005
Resolution: Corrected by the end of this inspection.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 8 July 2005 Resolved
Update all ship's certificate, as needed, to reflect new owner.
Action required: 705 - Other - as specified
Due 12 September 2005
Resolved 19 September 2005
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 14 April 2005 Resolved
Vessel unable to provide evidence of Standard Discharge Connection. Provide evidence to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 14 May 2005
Resolved 29 April 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 April 2005 Resolved
Bottom step on STBD AFT ladder leading from deck 7 to deck 8 found to be very weak. Repair step to satisfaction of attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 14 May 2005
Resolved 29 April 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 14 April 2005 Resolved
Unable to provide evidence of proper operation of MF/HF installation. Provide tech repot verifying proper operation.
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 12 May 2005
Resolution: Sat tech report rcvd and filed.
Fire Fighting › Means of Escape › Blocked
Issued 14 April 2005 Resolved
Means of escape partially blocked, deck 2, exiting engine room, leading to garage. Clear escape route to satisfaction of attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 29 April 2005
Lifesaving › Rigid Liferafts › Painter
Issued 7 October 2004 Resolved
Ensure float-free arrangement of life rafts and properly install painter/inflation line. Solas 74 as ammended III-26/2
Due 7 October 2004
Resolved 7 October 2004
Resolution: Corrected on the spot.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 7 October 2004 Resolved
Ensure all passenger brief cards (cabins) properly indicate correct evacuation routes. Solas 74 as ammended III-8
Action required: 705 - Other - as specified
Due 20 October 2004
Resolved 25 October 2004
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 7 October 2004 Resolved
Ensure all lifejackets have lights. Solas 74 as ammended III-26/5
Action required: 705 - Other - as specified
Due 20 October 2004
Resolved 25 October 2004
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 3 August 2004 No resolution recorded
On August 03, 2004, this office discovered that subject vessel did not submit the required ISSC information in a timely manner in accordance with the requirements outlined in 33 CFR 160 part C
Action required: 15 - Rectify deficiencies by next port
Resolution: Vessel submitted correct info
Fire Fighting › Miscellaneous Items
Issued 19 April 2004 Resolved
Key boxes missing break glass hammers in key boxes throught the ship.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 17 May 2004
Lifesaving › Lifeboat Equipment
Issued 15 October 2003 Resolved
PROVIDE FOOD RATIONS FOR ALL LIFEBOATS OR OBTAIN EXEMPTION CERTIFICATE FROM CLASS/FLAG STATE. LEGACY COMPONENT DESC: Food Ration
Action required: 15 - Rectify deficiencies by next port
Resolved 18 November 2003
Resolution: Class issued new exemption certificates.
Documentation › Certificates/Documents
Issued 15 October 2003 Resolved
VESSEL HAD AN EXPIRED ISM SAFETY MANAGEMENT (INTERIM) CERTIFICATE. LEGACY COMPONENT DESC: Document of Compliance (ISM)
Action required: 15 - Rectify deficiencies by next port
Resolved 29 October 2003
Resolution: RECEIVED FAX OF VALID ISM-SAFETY MANAGEMENT DOCUMENT.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 10 September 2003 Resolved
Quatities in cubic meters of types of garbage (plastics, victual, metal) not entered properly in garbage log.
Action required: 705 - Other - as specified
Resolved 10 September 2003
Resolution: Corrected by the master on 05Sep03 by way of memo to responsible person.
Documentation › Safety/Response Plans/Programs
Issued 13 April 2003 Resolved
Complete Fire Control Plan review with the Marine Safety Center. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Design Flaw
Due 30 June 2003
Resolved 15 August 2003
Documentation › Safety/Response Plans/Programs
Issued 13 April 2003 Resolved
Verfiy on board the Fire Control Plan with a Coast Guard Marine Inspector prior to 30 JUN 2003. LEGACY COMPONENT DESC: Fire Control Plans
Due 30 June 2003
Resolved 15 August 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 13 April 2003 Resolved
Secure video gams to deck or bulkhead, deck 6, starboard. LEGACY COMPONENT DESC: Recreation Space
Due 30 June 2003
Resolved 15 August 2003
Documentation › Markings/Placards
Issued 13 April 2003 Resolved
Post Passenger Safety Instructions in passenger cabins on deck 5 port side forward and port side aft. LEGACY COMPONENT DESC: Passenger Safety Instrucitons
Condition: Unknown
Due 30 June 2003
Resolved 15 August 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.