Records from 2003 to 2021. Most recent: inspection, 8 April 2021.
Inspection history · 34
8 April 2021
PSC B · COC-TVE Renew
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7167599
11 June 2018
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6437689
8 June 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6437858
2 June 2017
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6156334
23 May 2012
MARPOL Annex I Examination · COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4317328
9 November 2010
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3897316
11 October 2010
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3867867
28 January 2010
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3671950
2 May 2009
COC-TVE Renew · ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3465704
3 January 2009
ISPS I Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3387799
2 January 2009
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3387757
7 September 2008
ISPS I Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3319298
2 September 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3316095
30 July 2008
ISPS I Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3283632
28 July 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3282450
7 May 2008
COC-TVE Annual · Ballast Water Examination · ISPS III Exam · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3200689
2 April 2008
ISPS I Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3176187
26 March 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3171982
22 March 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3169420
11 January 2008
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3128540
26 April 2007
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2916521
4 January 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2849877
4 January 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2849890
17 April 2006
COC-TVE Annual · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2626163
11 October 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2511806
10 June 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2387036
16 March 2005
ISPS II Exam · COC-TVE Renew
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2309486
4 September 2004
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2186181
11 August 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2163844
10 July 2004
ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2128035
4 May 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2059055
30 March 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2034539
30 March 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2034725
6 March 2003
Certificate of Compliance · Ballast Water Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1756260
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 8 April 2021
Resolved
The IG system shall be designed and constructed to render the cargo tanks non-flammable at all times. An audilbe leak was detected on the main IG line in the vacinity of the number 3 stbd cargo tank.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2021
Resolved 8 April 2021
Resolution: class report recieved (attached) attesting to the repair of the IG Line.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 2 June 2017
Resolved
0199-other-The company should establish procedures, plans and onboard instructions for key ship board operations concerning safety/ The onboard instructions provided for the PV valves do not match the design of the actual PV vales in use on the ship. ISM Code 7
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 June 2017
Resolved 9 June 2017
Resolution: Recieved class report attesting to proper diagrams and plans on board. See documents.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (100 ppm)
Issued 24 May 2012
Resolved
1740-Oil discharge mon/contr system- Oil tankers of 150 gross tons and above shall be equipped with an ODME approved by the Admin. Due to failure of the flow switch on ODME, the switch was bypassed by tech to allow function of ODME until replacement part could be provided. System was logged as operational in ORB Part II, despite the system not being repaired as designed. MARPOL (11 Con ED) I/31.1
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2012
Resolved 29 May 2012
Resolution: ODME repaired per ABS Class surveyor [name withheld] and ABS Report # PA2154699.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 24 May 2012
Resolved
0720-Firefighting equipment-Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. 53 fire extinguishers were found to be beyond ten years old with no evidence of hydrostatic testing conducted for recertification. SOLAS(01 CON ED) REG 6
Action required: 17 - Rectify deficiencies prior to departure
Due 30 May 2012
Resolved 29 May 2012
Resolution: The Greek Administration has allowed a 1 year extension (not to exceed vessels drydock) for the hydrostatic testing of all fire extinguishers. Vessels drydock currently forecasted to occur December 2012.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 23 May 2012
Resolved
1735- Pumping Discharge arrangements- Each transfer pipe system must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. For vessels this test must be conducted annually or as part of the biennial and mid-period inspections. The cargo pumps have a head pressure of 13.5 kg/cm2 and the test pressure was 13.5 kg/cm2. 33 CFR 156.170(c)(4)
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 30 August 2012
Resolution: The vessel supplied paperwork attesting that they tested the cargo lines at the proper pressure.
Fire Fighting › Portable Foam Applicators › General
Issued 23 May 2012
Resolved
0720-Fire Fighting Equip.-Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. 02 foam extinguishers in the engine room and 01 foam extinguisher at the bottom of the pump room were tagged as not approved for service due to the extinguishers being overdue for hydrostatic testing.SOLAS(04 CON. ED) II-2/14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2012
Engineering › Electric Propulsion System › Circuit Board
Issued 11 January 2008
Resolved
Vessel's RPM indicator module in the engine control room was faulty. The indicator would show different RPM's and switch between forward and astern propulsion while operating in forward propulsion.
Action required: 705 - Other - as specified
Resolved 11 January 2008
Resolution: Technician replaced the RPM module, Class attested to the repairs. Repairs satisfactory.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 26 April 2007
Resolved
Port Lifeboat steering mechanism has failed due to steering ram mount failure. Emergency tiller system is still intact. Vessel is to make repairs to the satisfaction of certificate issuing authority. Vessel is also to provide class attestation to local OCMI no later than 26MAY07
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 21 May 2007
Resolution: Recieved Class (ABS) attestation that proper repairs have been made.