MAURY USCG vessel records Sign in
← All vessels

PA-POO

PA-POO is a 2003 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2003, most recently in April 2026, along with 19 deficiencies.

Records from 2003 to 2026. Most recent: inspection, 8 April 2026.

Built
2003
Last inspected
8 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

610103
Flag
UNITED STATES
—
Maury page id
psix-610103

Inspections, by type

Years with a record 15 calendar years (2003–2026)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it2 - Simplified, Gross Ton
2 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 16

8 April 2026 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8344907
29 January 2025 Examination of Repairs · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8071830
10 May 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7903362
13 March 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7878566
20 June 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7697235
23 June 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7469861
4 March 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7139481
10 February 2020 COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6896770
15 February 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6626095
16 February 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6352154
16 February 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6089490
4 February 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5808706
18 February 2011 Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3945178
23 March 2010 Drydock Exam · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3701142
22 August 2006 COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2756169
27 February 2003 Initial Certification · Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1750392

Deficiency record · 19

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 June 2023 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Emergency fuel shutoff found missing labeling. Label or mark. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 6 July 2023
Resolution: Received, reviewed, and accepted photograph from vessel rep showing proper labeling for emergency shutoff.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 June 2023 Resolved
The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Storage location for fire buckets found not labeled. Label or mark. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 6 July 2023
Resolution: Received, reviewed, and accepted photograph from vessel rep showing proper labeling for fire bucket location.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 June 2023 Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material...If posting is impracticable, such as in an open boat, the certificates must be kept on board in a weathertight container. Certificate of Inspection, Stability Letter, and Certificate of Documentation found not kept onboard. Retain copy onboard vessel. 46 CFR 176.302
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 6 July 2023
Resolution: Received, reviewed, and accepted photograph from vessel rep showing copies of vessel documentation retained onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2023 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Child life jacket found not marked with vessel's name. Label or mark. 46 CFR 185.604(b)
Action required: 10 - Deficiency Rectified
Due 20 June 2023
Resolved 20 June 2023
Resolution: Child life jacket was properly marked/labeled.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 June 2022 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel failed to complete annual inspection within 3 months of anniversary date of the COI.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 23 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 June 2022 Resolved
All fuel tanks must be electrically bonded to a common ground. Fuel tanks were not grounded, fix to the satisfaction of the attending CG Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 July 2022
Resolution: Fuel fill was grounded.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 February 2011 Resolved
Provide and install hand rails on vessel. The hand rails are to be constructed as discussed with [name withheld] and [name withheld].
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 13 April 2011
Resolution: Handrails installed to the satisfaction of the attending Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 25 October 2010 Resolved
Provide handrails in accordance with 46 CFR 177.900, or proposal for handrails providing equivalent level of safety to satisfaction of OCMI.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 26 January 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 March 2010 Resolved
Prior to carrying passengers for hire, make vessel available for COI examination, as per 46 CFR 176.500.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2010
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 23 March 2010 Resolved
Replace gasoline tank vent hose with one rated for fuel service.
Action required: 705 - Other - as specified
Due 25 November 2010
Resolved 23 March 2010
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 23 March 2010 Resolved
Repair fractures on midddle seat grab rail
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2010
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 March 2010 Resolved
Retain copy of COD
Action required: 705 - Other - as specified
Due 2 May 2010
Resolved 10 April 2010
Resolution: not required to have COD as vessel is not more than 5 GT
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 23 March 2010 Resolved
Tighten 90 degree fitting in fuel supply line, on top of fuel tank
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2010
Communications › Audible Communications › Horn/Whistle
Issued 23 March 2010 Resolved
Provide suitable horn or sound signal
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2010
Operations/Management › Drills/Instruction › Safety Orientation
Issued 23 March 2010 Resolved
Provide passenger safety orientation to be maintained onboard vessel
Action required: 705 - Other - as specified
Due 2 May 2010
Resolved 5 April 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 March 2010 Resolved
Provide Drug and Alcohol Prevention program
Action required: 705 - Other - as specified
Due 2 May 2010
Resolved 25 October 2010
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 23 March 2010 Resolved
Provide emergency instructions to be maintained onboard vessel as per 46 CFR 185.510
Action required: 705 - Other - as specified
Due 2 May 2010
Resolved 5 April 2010
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 23 March 2010 Resolved
Add vessel name to port and starboard bow as per 46 CFR 67.123
Action required: 705 - Other - as specified
Due 2 May 2010
Resolved 5 April 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 March 2010 Resolved
Prior to carrying passengers for hire, make vessel available for drycock examination as per 46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2010

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.