MAURY USCG vessel records Sign in
← All vessels

RANDALL B MCCALL

RANDALL B MCCALL is a 2003 offshore supply vessel. The Coast Guard has recorded 22 inspections since 2003, most recently in May 2014, along with 7 deficiencies, 1 operational control and 1 casualty investigation in 2012.

Records from 2003 to 2014. Most recent: inspection, 6 May 2014.

Built
2003
Last inspected
6 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9297395 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB4219
610182
Flag
UNITED STATES
369287000, 369290000 (licence lapsed)
Maury page id
psix-610182

Inspections, by type

…with no type recorded1
Years with a record 11 calendar years (2003–2014)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it141 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
472 - Convention (Subpart B), Gross Ton
91 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB4219MMSI 369287000 · cancelled · compulsorily equipped · granted 24 May 2013, cancelled 28 October 2015
WDB4245MMSI 369290000 · cancelled · compulsorily equipped · granted 5 June 2003, cancelled 22 April 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 22

6 May 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4851135
11 June 2012 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4341552
10 June 2012 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4788604
18 May 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4314081
2 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200187
14 September 2010 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3850661
1 April 2009 Hull Examination · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3449962
19 June 2008 COI Inspection · Ballast Water Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3241216
13 March 2007 MTSA Verification · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2887389
6 September 2006 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2770330
23 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571415
14 June 2005 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2390685
4 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303630
10 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290129
29 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2230864
21 July 2004 MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2140172
2 July 2004 MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2118838
2 July 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2119028
3 June 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2087761
7 April 2004 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2042176
16 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1967046
19 June 2003 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1821291

Deficiency record · 7

Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 19 June 2008 Resolved
At next drydock mount CO2 cylinders at least 2 inches from deck as per 46 CFR 181.410 (i)(6)
Due 4 April 2009
Resolved 13 April 2009
Resolution: Vessel''s CO2 cylinders were not in area subject to moisture as per 46CFR 181.410(c)(6)
Electrical › Electric Generation Source (service) › Generator
Issued 6 September 2006 Resolved
Clean Generator Armatures.
Due 7 October 2006
Resolved 12 September 2006
Resolution: Generator Armatures were cleaned.
Lifesaving › Lifefloat › Platform
Issued 6 September 2006 Resolved
Spacers separating lifefloats missing.
Due 7 October 2006
Resolved 12 September 2006
Resolution: Wooden spacers placed between lifefloats for proper storage.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 6 September 2006 Resolved
Label direction to stove disconnect, to be visible during a fire above stove.
Due 7 October 2006
Resolved 12 September 2006
Resolution: Stove Diconnect labeled above stove for easy viewing.
Lifesaving › Hand Flares › Expired
Issued 6 September 2006 Resolved
Distress signals expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2006
Resolution: Distress signals renewed.
Fire Fighting › Means of Escape › Blocked
Issued 6 September 2006 Resolved
Remove locks on escape hatches, and make the hatches operable.
Due 7 October 2006
Resolved 12 September 2006
Resolution: Locks on escape hatches removed and hatches are operable.
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 June 2003 Resolved
PROVIDE APPROVED PROPULSION CONTROL PLANS.
Action required: 705 - Other - as specified
Due 23 July 2003
Resolved 23 July 2003
Resolution: Approved plan was verified to satisfaction of CG marine inspector

Casualty record · 1

10 June 2012Routine · role: Involved in a Marine Casualty · activity 4788604
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.