MAURY USCG vessel records
← All vessels

SEA FAITH

SEA FAITH is a 2003 tank ship. The Coast Guard has recorded 11 inspections since 2016, most recently in January 2020, along with 6 deficiencies and 1 operational control.

Records from 2016 to 2020. Most recent: inspection, 28 January 2020.

Built
2003
Last inspected
28 January 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9258674
610298
Flag
MARSHALL ISLANDS
Maury page id
psix-610298

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it27627 - Convention (Subpart B), Gross Ton
12769 - Convention (Subpart B), Net Ton
55901 - Displacement, Ton
46345 - Dead Weight, Ton
27627 - Regulatory (Subpart C or D), Gross Ton
12769 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 11

28 January 2020 COC-TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6895312
13 May 2019 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6682897
2 April 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual · COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6654098
29 March 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6652273
27 January 2018 COE-Offshore · COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6344608
21 January 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6340965
20 June 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6181667
19 June 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6180095
27 April 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6134110
21 March 2017 Ballast Water Examination · NPV Safety Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6108833
22 August 2016 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5975085

Deficiency record · 6

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 21 March 2017 Resolved
1150-Loading and unloading equipment- The cond of the ship & equip shall be maintained to conform w/ the prov of the convention to ensure that the ship will remain fit to proceed to sea without presenting an unreasonable threat of harm to the environment. In the cargo pump room the stripping line on the #3 cargo pump had an undocumented patch on the pipe that was leaking. MARPOL Annex I/6.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2017
Resolution: Attending marine inspectors inspected the stripping pipe which had been replaced in kind, new piping and new flanges.
Fire Fighting › Means of Escape › Doorways
Issued 21 March 2017 Resolved
0960-Means of Escape-Escape route shall be maintained in a safe condition. The escape route from the lower engine room to the steering gear room has a door that cannot be closed. 74 SOLAS(04) 11-2/13.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 March 2017
Resolution: ABS attended the vessel and cleared at class level, door hinges were replaced in kind and door is functioning as manufactured.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 21 March 2017 Resolved
1410-Propulsion Main Eng-The machinery, boilers, and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended; The main propulsion eng has a jacket water leak on the number 5 cylinder. 74 SOLAS (04) 11-1/26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 June 2017
Resolution: Vessel submitted class report satisfying deficiency.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 21 March 2017 Resolved
0599-Other-Each device must be free of design defects such as rough or sharp edges that may cause bodily injuries or that would allow toxic substances to escape to the interior of the vessel. Vessels sewage tank has undocumented repair patches on it, at the pipe enterance and on the tank top. 33 CFR 159.95 (a)(1)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 June 2017
Resolution: Vessel submitted tech report satisfying deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 22 August 2016 Resolved
1199-other-Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of electrical fault in such areas, special precautionsagainst such risks shall be taken to the satisfation of the Administration. PSCO observed cargo pump temp sensors in pump room, with exposed wiring at stuffing tubes. Cite: 74SOLAS(Am.)II-1/45.5.4; Action taken: a
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2016
Resolved 24 August 2016
Resolution: 24AUG16: Received Class report attesting to the proper repair of cargo pump temperature sensor wiring.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 22 August 2016 Resolved
0611-Lifeboat inventory-Each survival craft shall be stowed fully equipped as required by this chapter and the Code. PSCO observed 10 vacuum seals out of the required 80 (40 for each lifeboat) food rations to have broken seals. Cite: 74SOLAS(14)III/13.1.4; Action taken: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 August 2016
Resolved 24 August 2016
Resolution: Received Class report and receipt attesting to the vessel receiving food rations.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.