MAURY USCG vessel records Sign in
← All vessels

SEA FAITH

SEA FAITH is a 2003 tank ship. The Coast Guard has recorded 37 inspections since 2003, most recently in January 2020, along with 19 deficiencies and 7 operational controls.

Records from 2003 to 2020. Most recent: inspection, 28 January 2020.

Built
2003
Last inspected
28 January 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9258674 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
610298
Flag
MARSHALL ISLANDS
—
Maury page id
psix-610298

Inspections, by type

…with no type recorded11
Years with a record 15 calendar years (2003–2020)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it27627 - Convention (Subpart B), Gross Ton
12769 - Convention (Subpart B), Net Ton
55901 - Displacement, Ton
46345 - Dead Weight, Ton
27627 - Regulatory (Subpart C or D), Gross Ton
12769 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 37

28 January 2020 COC-TVE Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6895312
13 May 2019 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6682897
2 April 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual · COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6654098
29 March 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6652273
27 January 2018 COE-Offshore · COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6344608
21 January 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6340965
20 June 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6181667
19 June 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6180095
27 April 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6134110
21 March 2017 Ballast Water Examination · NPV Safety Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6108833
22 August 2016 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5975085
23 December 2015 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5786192
22 December 2015 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5787130
30 November 2015 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5772070
12 September 2015 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5717232
13 August 2014 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4954192
11 August 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4946852
2 July 2012 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4359839
16 December 2010 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3911666
16 December 2010 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3911882
11 May 2009 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3472415
6 May 2009 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3469071
11 March 2008 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3162101
13 October 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2799964
18 April 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2627625
16 April 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2627189
21 November 2005 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2538300
18 November 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2537300
16 November 2005 ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2534462
28 October 2005 In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2523903
23 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2472029
18 June 2005 COC-TVE Renew · ISPS I Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2395047
20 June 2004 Type not recorded
No type recorded · GROUP HONOLULU · USCG Oceania District (CGD-O) · Activity 2106119
16 June 2004 MTSA/ISPS Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2095622
16 June 2004 COC-TVE Annual
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2100441
7 November 2003 Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 1953857
4 March 2003 Certificate of Compliance
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1754194

Deficiency record · 19

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 21 March 2017 Resolved
1150-Loading and unloading equipment- The cond of the ship & equip shall be maintained to conform w/ the prov of the convention to ensure that the ship will remain fit to proceed to sea without presenting an unreasonable threat of harm to the environment. In the cargo pump room the stripping line on the #3 cargo pump had an undocumented patch on the pipe that was leaking. MARPOL Annex I/6.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2017
Resolution: Attending marine inspectors inspected the stripping pipe which had been replaced in kind, new piping and new flanges.
Fire Fighting › Means of Escape › Doorways
Issued 21 March 2017 Resolved
0960-Means of Escape-Escape route shall be maintained in a safe condition. The escape route from the lower engine room to the steering gear room has a door that cannot be closed. 74 SOLAS(04) 11-2/13.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 March 2017
Resolution: ABS attended the vessel and cleared at class level, door hinges were replaced in kind and door is functioning as manufactured.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 21 March 2017 Resolved
1410-Propulsion Main Eng-The machinery, boilers, and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended; The main propulsion eng has a jacket water leak on the number 5 cylinder. 74 SOLAS (04) 11-1/26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 June 2017
Resolution: Vessel submitted class report satisfying deficiency.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 21 March 2017 Resolved
0599-Other-Each device must be free of design defects such as rough or sharp edges that may cause bodily injuries or that would allow toxic substances to escape to the interior of the vessel. Vessels sewage tank has undocumented repair patches on it, at the pipe enterance and on the tank top. 33 CFR 159.95 (a)(1)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 June 2017
Resolution: Vessel submitted tech report satisfying deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 22 August 2016 Resolved
1199-other-Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of electrical fault in such areas, special precautionsagainst such risks shall be taken to the satisfation of the Administration. PSCO observed cargo pump temp sensors in pump room, with exposed wiring at stuffing tubes. Cite: 74SOLAS(Am.)II-1/45.5.4; Action taken: a
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2016
Resolved 24 August 2016
Resolution: 24AUG16: Received Class report attesting to the proper repair of cargo pump temperature sensor wiring.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 22 August 2016 Resolved
0611-Lifeboat inventory-Each survival craft shall be stowed fully equipped as required by this chapter and the Code. PSCO observed 10 vacuum seals out of the required 80 (40 for each lifeboat) food rations to have broken seals. Cite: 74SOLAS(14)III/13.1.4; Action taken: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 August 2016
Resolved 24 August 2016
Resolution: Received Class report and receipt attesting to the vessel receiving food rations.
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 12 September 2015 Resolved
0715-MANUALLY OPERATED CALL POINTS SHALL BE READILY ACCESSIBLE IN THE CORRIDORS OF EACH DECK SUCH THAT NO PART OF THE CORRIDOR IS MORE THAN 20M FROM A MANUALLY OPERATED CALL POINT. CALL POINT A012 IN ZONE 002, WHICH IS LOCATED IN THE CENTER OF "C" DECK IS NOT OPERATIONAL. THE DISTANCE BETWEEN THE 2 REMAINING OPERATIONAL CALL POINTS IS GREATER THAN 20M
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 September 2015
Resolved 30 November 2015
Resolution: received tech report attesting to proper operation of all manually operated call points
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 2 July 2012 Resolved
To assist in casualty investigations, ships when engaged on international voyages shall be fitted with a voyage data recorder. VDR is inoperable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 November 2012
Resolution: Recieved a copy of the tech report showing the VDR is repaired.
Construction/Loadline › Markings › Load Line Mark
Issued 2 July 2012 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground. The load line markings are rusted and are not of contrasting color.
Action required: 705 - Other - as specified
Resolved 10 November 2012
Resolution: Load lines were repainted with a contrasting color.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 16 December 2010 Resolved
1410: The vessel had a loss of propulsion and a loss of main electrical power while transiting inbound to load cargo. The vessel is required to submit documentation from the certificate issuing authority attesting to the proper operation of both systems.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2010
Resolved 17 December 2010
Resolution: The vessel submitted a class report attesting to the repairs.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 16 December 2010 Resolved
1410: The vessel had a loss of propulsion and a loss of main electrical power while transiting inbound to load cargo. The vessel is required to submit documentation from the certificate issuing authority attesting to the proper operation of both systems.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2010
Resolved 17 December 2010
Resolution: The vessel submitted a class report attesting to the repairs.
Fire Fighting › Fire Hoses › Number
Issued 16 November 2005 Resolved
Provide number of hoses IAW safety equipment certificate prior to departure.
Action required: 705 - Other - as specified
Resolved 18 November 2005
Resolution: Vessel provided serviceable number of fire hoses required by safety equipment certificate.
Lifesaving › Inflatable Liferafts › Float Free
Issued 16 November 2005 Resolved
Provide forward starboard life raft in a float-free condition prior to departure.
Action required: 705 - Other - as specified
Resolved 18 November 2005
Resolution: Life raft stowed in float free conditon according to manufactures instructions.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 16 November 2005 Resolved
Conduct life boat/ abandon ship drill prior to departure from port.
Action required: 705 - Other - as specified
Resolved 18 November 2005
Resolution: Satisfactory drills conducted.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 16 November 2005 Resolved
Provide proper ballast water report prior to departure from port.
Action required: 705 - Other - as specified
Resolved 18 November 2005
Resolution: Amended ballast water report provided.
Construction/Loadline › Markings › Load Line Mark
Issued 16 November 2005 Resolved
Mark load lines IAW International Load Line Certificate to the satisfaction of Coast Guard inspector prior to next US port after Sailing foreign.
Action required: 705 - Other - as specified
Resolved 18 April 2006
Resolution: Deficiency cleared.
Deck/Cargo › Inert Gas System › Venting System
Issued 16 November 2005 Resolved
Prove proper operation of high pressure alarm for inert gas system prior to departure from St. Croix to the satisfaction of Coast Guard Inspector.
Action required: 705 - Other - as specified
Resolved 18 November 2005
Resolution: Deck High pressure alarm satisfactorily tested.
Construction/Loadline › Penetrations › Pipe Flange
Issued 16 June 2004 Resolved
Discontinue use of Cargo Pump #4 and Cargo line #4. Prior to next U.S. port, class/adminitstration must attest to proper operation and construction of cargo line #4. Specifically flange located one deck above cargo pumps. USCG PSCO's noted product (jet fuel) leaking from noted flange in piping in pump room. SOLAS 74/78 CH I REG 11
Action required: 15 - Rectify deficiencies by next port
Resolved 23 June 2004
Resolution: RECEIVED CLASS REPORT
Accommodation/Occupational Safety › Ventilation › General
Issued 16 June 2004 Resolved
Until deficiency for cargo line #4 is cleared, for future cargo operations in U.S. waters, 30 minutes prior to operating cargo pumps, have certified marine chemist ensure that environment in pumproom is gas-free 33CFR32.60-20(c)
Action required: 705 - Other - as specified
Resolved 23 June 2004
Resolution: RECEIVED CLASS REPORT

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.