← All vessels
YASH
YASH is a 2002 tank ship. The Coast Guard has recorded 14 inspections since 2003, most recently in February 2024, along with 3 deficiencies and 1 operational control.
Records from 2003 to 2024. Most recent: operational control imposed, 1 February 2024.
- Built
- 2002
- Last inspected
- 1 February 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9231183 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5LDV6
610324
Flag
LIBERIA
—
Maury page id
psix-610324
Inspections, by type
…with no type recorded2
Years with a record
8 calendar years (2003–2024)
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it25651 - Convention (Subpart B), Gross Ton
9111 - Convention (Subpart B), Net Ton
37320 - Dead Weight, Ton
46306 - Displacement, Ton
9111 - Convention (Subpart B), Net Ton
37320 - Dead Weight, Ton
46306 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 14
1 February 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7858920
26 January 2024
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7856418
18 October 2023
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7808204
5 October 2023
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7804067
27 April 2018
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6400430
5 April 2018
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6385923
26 June 2012
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4357288
14 July 2006
COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2712259
1 December 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2543848
5 June 2005
COC-CHEM Renew
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2381176
27 January 2005
Deficiency Check · ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2281532
30 March 2004
MARPOL Annex I Examination · Certificate of Compliance · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2034117
10 March 2003
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1754973
9 March 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1754874
Deficiency record · 3
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 18 October 2023
Resolved
The Master or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the following ballast water management methods: Install and operate a ballast water management system that has been approved by the Coast Guard. It was reported to the PSCO that the installed ballast water treatment system is inoperable "due to control air contamination". This condition resulted in V1*03 valve positioner pneumatic block not being able to function as designed.
33CFR151.2025(a)(1)
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 14 July 2006
Resolved
Vessel's incinerator was inoperative due to a broken solenoid valve in pre iginition component
Construction/Loadline › Markings › Load Line Mark
Issued 30 March 2004
Resolved
Loadline on vessel does not match certificate or amendment issued by class. Class society must attest to proper location, markings and installation prior to 30APR04.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.