Records from 2003 to 2022. Most recent: inspection, 6 June 2022.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
6 June 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7447957
27 January 2021
Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7131909
13 August 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7032168
13 February 2020
Drydock Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6908450
22 March 2019
DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6688680
22 February 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6630593
21 February 2018
COI Inspection · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6359136
14 March 2017
Annual Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6100568
21 April 2016
Annual Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5859688
20 May 2014
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4848473
23 January 2012
Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4230211
23 March 2010
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3696252
4 May 2009
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3467391
2 June 2008
COI Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3213820
7 June 2007
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2946632
8 June 2006
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2666390
17 June 2005
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2377282
10 June 2004
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2086588
17 June 2003
Initial Certification · Simplified Stability Test · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1810352
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 June 2022
No resolution recorded
Vessel is overdue for its Annual Inspection. Make the vessel available for Annual Inspection by USCG marine inspectors.
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 January 2021
Resolved
Only two fire buckets were found / located on vessel.
Add third 2.5 gal fire bucket to vessel inventory.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: Procured third fire bucket and added to vessel's inventory.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 27 January 2021
Resolved
Vessel was unable to provide adequate air compressor for PRV test procedures.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2021
Resolution: Owner provided documentataion and video of Satisfactory test of PRV's.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 February 2020
Resolved
All fuel and hydraulic lines must be in good condition and leak free. It was discovered that one fuel and one hydraulic line to the outboard engines were leaking. Must conduct necessary repairs and/or replacements of lines to the satisfaction of the CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2020
Resolved 10 February 2021
Resolution: Deficiency checked and cleared onsite...[name withheld]
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 February 2020
Resolved
All vessels must be structurally sound and intact for general safety. It was discovered that the strap on the port bow section of the main cabin to the sponson was severely frayed. Strap must be replaced to the satisfaction of the CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2020
Resolved 10 February 2021
Resolution: Deficiency corrected and verified onsite...[name withheld]
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 February 2020
Resolved
All vessels must be structurally sound and intact for general safety. Relief valves on the port sponson were not popping at set pressure. Must prove function of relief valves to satisfaction of the CG Marine Inspector
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2020
Resolved 10 February 2021
Resolution: Deficiency corrected and verified onsite...[name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 February 2019
Resolved
Remove current bilge pump and Install UL listed electric submersible bilge pump.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 26 February 2020
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 February 2019
Resolved
re-seal all seams on both rubber pontoons.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 February 2019
Resolved
Implement a proper drug and alcohol program to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2019
Resolution: DAPI PROGRAM COMPLETED AND REVIEWED BY [name withheld]
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 March 2017
Resolved
Renew battery.
Due 14 April 2017
Resolved 14 March 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 March 2017
Resolved
Provide life ring light lanyard.
Due 14 April 2017
Resolved 14 March 2017
Personnel › Manning/Qualifications › Medical Fitness
Issued 14 March 2017
Resolved
Provide up to date medical cards for credentialed mariners.
Due 14 April 2017
Resolved 16 June 2017
Lifesaving › Hand Flares › Expired
Issued 14 March 2017
Resolved
provide three orange/day hand flares.
Due 14 April 2017
Resolved 14 March 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 January 2012
Resolved
Replace 06 type 1 lifejackets that failed inspection. Vessel restricted to 12 adults until replaced.
Action required: 705 - Other - as specified
Due 12 April 2012
Resolved 15 March 2012
Resolution: Replaced all 06 lifejackets.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 January 2012
Resolved
Replace retroreflective tape and re stencil name on lifering buoy.
Action required: 705 - Other - as specified
Due 12 April 2012
Resolved 15 March 2012
Resolution: Replaced retro tape and re-labeled name on buoy.
Lifesaving › Hand Flares › Quantity
Issued 23 March 2010
Resolved
Missing 2 day flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2010
Construction/Loadline › Hull › Stiffener
Issued 23 March 2010
Resolved
Weld crack on the #12 (last) stiffener at the center weld.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 24 March 2010
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 8 June 2006
Resolved
Provide MIS submission form and drug program records.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2006
Resolved 22 June 2006
Resolution: Received faxed copy of MIS report.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 June 2003
Resolved
Provide proper rails around passenger deck. LEGACY COMPONENT DESC: Deck Rail
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2003
Resolved 22 August 2003
Resolution: Received letter and photographs from owner showing satisfactory railings in passenger area.
Lifesaving › Lifejacket/PFD (Type I)
Issued 17 June 2003
Resolved
Provide one additional adult PFD. LEGACY COMPONENT DESC: Quantity
Due 17 July 2003
Resolved 19 June 2003
Lifesaving › Lifebuoys
Issued 17 June 2003
Resolved
Provide 3 - 6 ft. lanyard for waterlight. LEGACY COMPONENT DESC: Self-igniting Lights
Due 17 July 2003
Resolved 19 June 2003
Navigation › Collision/Grounding Avoidance
Issued 17 June 2003
Resolved
Provide all-around white light above kayak rack. LEGACY COMPONENT DESC: Navigation Lights
Due 17 July 2003
Resolved 22 August 2003
Resolution: Received letter and invoice from owner showing satisfactory navigation light received.
Deck/Cargo › Mooring/Anchoring
Issued 17 June 2003
Resolved
Provide suitable anchor and line. LEGACY COMPONENT DESC: Anchor
Due 17 July 2003
Resolved 22 August 2003
Resolution: Received letter and photograph from owner showing adequate ground tackle.
Electrical › Lighting (emergency)
Issued 17 June 2003
Resolved
Provide 2 flashlights. LEGACY COMPONENT DESC: Battery Operated Lantern
Due 17 July 2003
Resolved 19 June 2003