Records from 2001 to 2020. Most recent: inspection, 26 February 2020.
Inspection history · 35
26 February 2020
Administrative Inspection · PSC B · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6915903
12 December 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6872968
8 December 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6869383
29 November 2019
Deficiency Check · PII Safety Exam · In-Service Inspection · ISPS III Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6864477
28 November 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6864611
5 June 2019
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6704958
25 November 2017
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6312399
6 June 2014
Deficiency Check · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4880636
9 March 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3692840
20 July 2009
COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3540459
27 September 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3359031
18 September 2008
ISPS II Exam · COC-CHEM Annual
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3325934
5 July 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2984004
4 July 2007
ISPS III Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2980517
26 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2974692
5 August 2006
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2731619
28 March 2006
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2611829
25 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2609382
1 October 2005
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2505395
8 July 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2419804
8 July 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2422547
16 June 2005
ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2392503
15 June 2005
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2392135
9 July 2004
NPV Safety Exam · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2126896
1 April 2004
Certificate of Compliance · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2035351
7 July 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1839191
5 July 2003
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1835916
3 July 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1833804
23 June 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1825260
21 March 2003
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1760639
14 March 2003
Security Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1758324
7 March 2003
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1754274
2 March 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1753220
1 March 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1754565
1 February 2001
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2508625
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 February 2020
Resolved
11101-LIFEBOAT-THE ENGINE SHALL BE CAPABLE OF OPERATING FOR NOT LESS THAN 5 MIN AFTER STARTING FROM COLD WITH THE LIFEBOAT OUT OF THE WATER. WHILE EXAMINING PORT SIDE LIFEBOAT, VESSEL CREW WAS UNABLE TO START THE ENGINE. [name withheld] OF THE EXAMINATION AND RETURNED BACK TO LIFEBOAT AFTER AN HOUR AND LIFEBOAT ENGINE WAS STILL NOT ABLE TO START.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2020
Resolved 27 February 2020
Resolution: Electric cable connection was cleaned, cable lugs were renewed and retightened, class report report recieved on 27FEB2020 confirming repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 November 2019
Resolved
The machinery, boilers and the pressure vessels, associated piping systems and fitting should be of a design and construction adequate for the service for which that are intended. The vessel Master reported that vessel experienced a propulsion failure while attempting to get underway. Chief Engineer stated that Unit #6 fuel pump reversing cylinder was stuck in Ahead position. SOLAS 74/78 04'Cons. II-1/26.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2019
Resolved 29 November 2019
Resolution: Rcvd Class Report. Vsl Cleared to depart the Port of New Haven.
Electrical › Electric Generation Source (emergency) › Generator
Issued 6 June 2014
Resolved
The vessels's emergency generator nor the transitional source of emergency electrical power never started following the loss of all main electrical power.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2014
Resolved 7 June 2014
Resolution: Received ABS class survey report attesting to proper operation of system.
Electrical › Electric Generation Source (service) › Generator
Issued 6 June 2014
Resolved
The vessel lost all power while shifting generators during its transit into port and was at complete blackout for approximately 2 minutes.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 June 2014
Resolved 7 June 2014
Resolution: Received ABS class survey report attesting to proper operation of system.
Personnel › Certificates/Documents/Licenses
Issued 7 March 2003
Resolved
The chief Engineer and Second Engineer do not have Flag State Endorsements or documentary proof of application for Flag State Endorsements. LEGACY COMPONENT DESC: STCW Endorsement
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2003
Resolved 8 March 2003
Resolution: Received proper documentation satisfying requirement.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 7 March 2003
Resolved
Number 3 starboard cargo tank high level alarm does not operate as designed. Visual alarm in the control room flashes when cargo tank is empty. Make permanent repairs to the satisfaction of class prior to loading number 3 starboard. LEGACY COMPONENT DESC: High Level Alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2003
Resolved 5 July 2003
Resolution: Rcvd class report attesting repairs of alarm system
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 7 March 2003
Resolved
High level audible alarm on deck is inoperable. Witnessed satisfactory operation of high level alarms in cargo control room and visual alarm on deck. LEGACY COMPONENT DESC: High Level audible alarms
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2003
Resolved 5 July 2003
Resolution: Rcvd class report attesting repairs of alarm system