ARDMORE SEATRADER

ARDMORE SEATRADER is a 2002 tank ship. The Coast Guard has recorded 4 inspections since 2016, most recently in September 2018, along with 6 deficiencies and 2 operational controls.

Records from 2016 to 2018. Most recent: operational control imposed, 26 September 2018.

Built
2002
Last inspected
26 September 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9240847
610661
Flag
MARSHALL ISLANDS
Maury page id
psix-610661

Inspections, by type

…with no type recorded1
Years with a record 3 calendar years (2016–2018)
The 4 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it28552 - Convention (Subpart B), Gross Ton
12369 - Convention (Subpart B), Net Ton
56524 - Displacement, Metric Ton
47141 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 4

26 September 2018 Deficiency Check · Ballast Water Examination · COC-TVE Renew · Administrative Inspection · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6543423
6 January 2017 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6066811
19 August 2016 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5975199
17 August 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5975410

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 September 2018 Resolved
07113-Fire pumps and it's pipes- In cargo ships of 2000GT and upwards, if a fire in any one compartment could put all pumps out of action there shall be an alternative means consisting of a fixed independently driven emergency pump which shall be capable of supplying two jets of water to the satisfaction of the Administration. The emergency fire pump cannot get suction. 74 SOLAS (2001) II-2/4.3.3.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 26 September 2018
Resolved 28 September 2018
Resolution: Class report submitted, 28SEP18 attesting to the rectification of noted deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 September 2018 Resolved
07126-Oil accumulation in engine room- In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO found excessive fuel leaks on the main engine. 74SOLAS(2001) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 26 September 2018
Resolved 27 September 2018
Resolution: Class report submitted, 27SEP18 attesting to the rectification of noted deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 September 2018 Resolved
07126-Oil accumulation in engine room- In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO found oil soak lagging throughout the engine room.74SOLAS(2001) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 26 September 2018
Resolved 27 September 2018
Resolution: Class report submitted, 27SEP18 attesting to the rectification of noted deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 September 2018 Resolved
07126-Oil accumulation in engine room- In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO found excessive fuel leaks on the ship diesel generators 74SOLAS(2001) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2018
Resolved 27 September 2018
Resolution: Class report submitted, 27SEP18 attesting to the rectification of noted deficiency.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 26 September 2018 Resolved
07102-Inert Gas System- Special considerations shall be given to the design and location of scrubber and blowers with relevent piping and fittings in order to protect flue gas leakages into enclosed spaces. PSCO found #1 and #2 blowers shaft seals leaking inert gas into the space. 74SOLAS (2001) II-2/62.8.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 September 2018
Resolution: Class report submitted, 28SEP18 attesting to the rectification of noted deficiency.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 26 September 2018 Resolved
07102-Inert Gas System- The system shall be capable of delivering inert gas with an oxygen content of not more than 5% by volume in the inert gas supply main to the cargo tanks at any required rate of flow. Oxygen analyzer could not be calibrated. 74SOLAS(2001) II-2/62.3.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 September 2018
Resolution: Class report submitted, 27SEP18 attesting to the rectification of noted deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.