MAURY USCG vessel records Sign in
← All vessels

REEL DEAL

REEL DEAL is a 2003 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2003, most recently in August 2026, along with 25 deficiencies.

Records from 2003 to 2026. Most recent: inspection, 12 August 2026.

Built
2003
Last inspected
12 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC9096
611041
Flag
UNITED STATES
367097510 (licence lapsed)
Maury page id
psix-611041

Inspections, by type

Years with a record 18 calendar years (2003–2026)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)35.7 ft × 14.0 ft × 6.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA HAWK INDUSTRIES INC · SEBRING, FL, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portTOLEDO, OH
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 4 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC9096MMSI 367097510 · expired · compulsorily equipped · granted 29 December 2015, cancelled 9 May 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

12 August 2026 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8462812
22 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8192024
30 April 2024 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8024615
8 May 2023 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7684472
14 December 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7609047
18 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7453851
22 April 2021 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7180502
8 April 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7174306
28 April 2020 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6945116
14 May 2019 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6684612
26 April 2018 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6390170
11 December 2017 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6322288
27 April 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6134363
14 April 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 5854358
7 May 2014 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4846581
28 April 2009 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3456428
9 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2925850
24 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2657962
3 May 2005 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2347971
22 July 2004 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2141148
17 June 2004 Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2101113
12 May 2003 COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1792037
8 May 2003 Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1789115

Deficiency record · 25

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 May 2023 Resolved
VESSELS ON A GREAT LAKE ROUTE SHALL CARRY SIX HAND RED FLARES AND SIX HAND ORANGE SMOKE DISTRESS SIGNALS. VESSEL HAD NO RED FLARES ON BOARD. 46 CFR 180.68(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 22 May 2023
Resolution: Owner [name withheld] number of distress signals.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 May 2023 Resolved
EACH VESSEL SHALL CARRY ON BOARD A FIRST AID KIT APPROVED IN ACCORDANCE WITH 46 CFR 160.041 OF THIS PART. THE VESSEL HAD A FIRST AID KIT THAT DID NOT MEER THE REQUIREMENTS OF 160.041. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 22 May 2023
Resolution: Owner provided Approved First Aid Kit.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 April 2021 Resolved
Vessel Replaced EPIRB with a Category II EPIRB. Vessel is required to be equipped with a Category I EPIRB. Vessel is required to replace EPIRB and operate inside of 3 Nautical Miles from shore until the EPIRB is the correct type and mounted in a float free arrangement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 22 April 2021
Resolution: Vessel owner provided proper releasing bracket and float free arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 April 2021 Resolved
During maintenance on life float, vessel owner noted that light attached to Life Float was not operating correctly. Light was ordered prior to inspection but did not arrive in time for inspection. Attach light per 46 CFR 180.175 once it is received.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2021
Resolved 19 April 2021
Resolution: New life float installed as required.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 28 April 2020 Resolved
EPIRB Battery expired on 11/2019. New EPIRB Battery needs to be installed. Or new EPIRB purchased.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2020
Resolved 4 May 2020
Resolution: Purchased new EPRIB and installed on vessel. Registration updated with new serial number.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 May 2019 Resolved
EPRIB Certification/registration Expired sept 2018. Owner is to re-certiify EPIRB registration within 14 days
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 16 May 2019
Resolution: Vessel owner provided proof of EPIRB registration.
Documentation › Certificates/Documents › FCC SSL
Issued 27 April 2017 Resolved
FCC Station License Expired
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 19 June 2017
Resolution: Renewed as required.
Documentation › Certificates/Documents › FCC SSL
Issued 27 April 2017 Resolved
Great Lakes Radio Authorization Expired
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 20 June 2017
Resolution: Renewed as required
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 27 April 2017 Resolved
Emergency Equipment Maintenance Logs Missing
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 19 June 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 April 2017 Resolved
Drills Log Missing / Man Overboard - Fire
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 19 June 2017
Engineering › Steering Gear System › Linkage
Issued 27 April 2017 Resolved
Auxiliary Means of Steering non operational
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 26 April 2018
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 April 2016 Resolved
Provide 03 adult size life jackets in order to meet the requirments on COI. Vessel is restricted to carrying no more than 15 total persons until lifejackets are place in service as required. Condemed 03 kapoc style life jackets.
Action required: 705 - Other - as specified
Resolved 26 April 2016
Resolution: Recieved reciept for purchase of 04 new adult Type I PFD's.
Lifesaving › Lifefloat › Painter
Issued 7 May 2014 Resolved
Lifefloat painter not attached to vessel. Properly attach lifefloat painter.
Action required: 705 - Other - as specified
Due 7 May 2014
Resolved 7 May 2014
Resolution: Corrected during inspection.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 May 2005 Resolved
Log monthly drills and inspection of lifesaving equipment
Due 30 June 2005
Resolved 30 June 2005
Resolution: Vessel has new logs with resent drills and equipment checks logged.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 3 May 2005 Resolved
Ensure passenger count is left ashore.
Condition: Unknown
Due 3 June 2005
Resolved 30 June 2005
Resolution: Vessel has passenger count logs, all sat.
Communications › Radio Communications › VHF Radiotelephone
Issued 3 May 2005 Resolved
Provide proof of radio operators permit
Due 3 June 2005
Resolved 30 June 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2005 Resolved
Ensure items in first aid kit are not expired
Due 3 June 2005
Resolved 30 June 2005
Resolution: Vessels owner replaced all outdated items in the 1st aid kit.
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2005 Resolved
Ensure vessel has a copy of the Navigation Rules and chart on-board
Condition: Unknown
Due 3 June 2005
Resolved 5 July 2005
Resolution: A new chart and nav rules was observed on board.
Stability › Watertight Integrity › Coaming
Issued 3 May 2005 Resolved
Make aft deck hatch water-tight
Condition: Unknown
Due 3 June 2005
Resolved 3 May 2005
Resolution: Installed coaming in the aft deck hatch
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 June 2004 Resolved
Mount new ABC Dry Chemical 5lb Extinguisher
Due 21 July 2004
Resolved 22 July 2004
Fire Fighting › Ventilation Systems › Operating Controls
Issued 17 June 2004 Resolved
Relocate and label both vent shut downs
Due 21 July 2004
Resolved 22 July 2004
Engineering › Fuel Oil Service System › Valve
Issued 17 June 2004 Resolved
Properly label the emergency fuel shut off valves
Due 21 July 2004
Resolved 22 July 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 17 June 2004 Resolved
Obtain Great Lakes Agreement radio inspection
Due 21 July 2004
Resolved 22 July 2004
Construction/Loadline › Hull
Issued 12 May 2003 Resolved
Make vessel available for a complete plan review audit at the convenience of the CG.
Condition: Placed in Improper Service
Due 3 August 2003
Resolved 24 July 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 12 May 2003 Resolved
Install insulation of the engine exhaust manifold riser and turbo charger as per 46CFR182.430(b)(3). LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper Installation
Due 4 July 2003
Resolved 24 July 2003
Resolution: Not required, system is water cooled.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.