Records from 1996 to 2026. Most recent: inspection, 22 January 2026.
Inspection history · 15
22 January 2026
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8299910
3 February 2025
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8073643
24 January 2024
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7859894
27 January 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7623494
26 October 2021
COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7339759
17 October 2021
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7330995
21 July 2021
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7263197
11 March 2014
Administration
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 4813843
9 August 2012
Administration
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4423287
12 August 2011
Spot Check (Safety)
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4113320
17 October 2000
Type not recorded
No type recorded · Station Oswego · USCG Great Lakes District (CGD-GL) · Activity 1517315
14 October 1999
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 767784
10 October 1999
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 208883
7 October 1996
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 767550
2 October 1996
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 207699
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 February 2025
No resolution recorded
A towing vessel subject to this sub-chapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Owner did not schedule annual inspection during 6 month inspection window. The COI is now expired. A new COI inspection is required prior to commercial operations.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 January 2023
Resolved
Air receiver MAWP is 150 psi and has a safety relief installed for 175 psi. Remove safety and install new that is at or below MAWP for receiver.
CITE
46 CFR 143.300
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 February 2023
Resolution: Removed safety and install new one rated for 140 psi
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 January 2023
Resolved
Bilge pump in workshop was not mounted properly. Remount pump.
CITE
46 CFR 143.205
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 February 2023
Resolution: Remounted pump.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 January 2023
Resolved
Battery solar charger had alligator clips for connection. Remove clips and install permanent connection.
CITE
46 CFR 143.555
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2023
Resolved 28 February 2023
Resolution: Removed clips and installed permanent connection.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 January 2023
Resolved
Fire extinguisher by shaft has wrong bracket. Install new bracket.
CITE
46 CFR 142.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2023
Resolved 28 February 2023
Resolution: Installed new bracket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2023
Resolved
Air receiver installed unable to determine size. Send paperwork for receiver.
CITE
46 CFR 143.300(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2023
Resolved 28 February 2023
Resolution: Received paperwork for receiver
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 January 2023
Resolved
Did not have service report for heat detectors. Provide report.
CITE
46 CFR 142.330(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2023
Resolved 28 February 2023
Resolution: Received paperwork for heat detectors.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 27 January 2023
Resolved
Abandon ship drill not logged. Completed today and logged.
Action required: 10 - Deficiency Rectified
Resolved 27 January 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 October 2021
Resolved
A TOWING VESSEL THAT IS CERTIFICATED FOR RIVERS, LAKES BAYS AND SOUNDS, LESS THAN 3 NAUTICAL MILES FROM SHORE ON THE GREAT LAKES MUST BE EQUIPPED WITH EITHER: AN APPROVED 160-B SEMI PORTABLE FIRE EXTINGUISHING SYSTEM TO PROTECT THE ENGINE ROOM; OR A FIXED FIRE-EXTINGUISHING SYSTEM INSTALLED TO PROTECT THE ENGINE ROOM. WEST WIND IS NOT OUTFITTED WITH EITHER REQUIRED ENGINE ROOM FIRE PROTECTION.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 27 January 2023
Resolution: Semi-portable extinguisher installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 October 2021
Resolved
CLOSURE DEVICES MUST BE PROVIDED FOR DECKHOUSE PENETRATIONS WHICH OPEN TO THE EXTERIOR OF THE VESSEL AND WHICH MAY ALLOW WATER TO ENTER THE VESSEL. THESE DEVICES MUST BE SUITABLE FOR THE EXPECTED ROUTE. PORT AND STARBOARD ENTRY INTO THE PILOTHOUSE, AND THE PORT ENTRY INTO THE CREW SPACE WAS NOT WEATHER TIGHT. DOORS ARE TO BE MADE WEATEHR TIGHT. ENTRANCE TO THE ENGINE ROOM FROM THE AFT DECK IS TO BE MADE WATERTIGHT, GASKET MATERIAL MUST BE REPLACED WITH PROPER MATERIAL.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2021
Resolved 28 February 2023
Resolution: Replaced gaskets.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 October 2021
Resolved
VESSEL MUST MAINTAIN MOST CURRENT CHARTS AND PUBS. WHILE THEY WERE PORVIDED ONBOARD ON IPAD, CAPTAIN WAS UNAWARE THAT THEY WERE LOCATED THERE.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 27 January 2023
Resolution: Charts and pubs updated. Master was aware.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 26 October 2021
Resolved
THE OWNER OR MASTER OF EACH TOWING VESSEL MUST MAINTAIN THE REQUIRED NAVIGATIONAL-SAFETY EQUIPMENT IN A FULLY-FUNCTIONING, OPERATIONAL CONDITION. RADAR IN LOWER WHEELHOUSE WAS NOT FUNCTIONING.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 28 February 2023
Resolution: Labeled lower wheelhouse chart plotter as not a radar and amending COI.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 26 October 2021
No resolution recorded
TOWING VESSELS MUST BE EQUIPPED WITH A FATHOMETER. TO BE INSTALLED AT NEXT DRY DOCKING.
Action required: 705 - Other - as specified
Due 1 November 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 October 2021
Resolved
VESSEL REQUIRED TO HAVE THREE BALL DAY SHAPES.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 27 January 2023
Resolution: Had 3 ball day shapes on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 October 2021
Resolved
ALL LIFEJACKET CONTAINERS MUST BE MARKED IN BLOCK CAPITAL LETTERS AND NUMBERS WITH MINIMUM QUANTITY. SPACE NOT LABELED.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 27 January 2023
Resolution: Life jacket stowage was labeled.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 October 2021
Resolved
EACH TOWING VESSEL MUST BE EQUIPPED WITH AN INDUSTRIAL TYPE FIRST AID KIT AND MUST HAVE MEANS TO TAKE BLOOD PRESSURE READINGS, SPLINT BONES AND APPLY LARGE BANDAGES. KIT DID NOT INCLUDE BLOOD PRESSURE CUFF.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 27 January 2023
Resolution: Had blood pressure cuff with first aid kit.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 26 October 2021
Resolved
EACH VESSEL MUST HAVE POSTED THE GARBAGE PLACARD. PLACARD ONBOARD WAS OUT OF DATE AND NEEDS REPLACING.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 27 January 2023
Resolution: Posted garbage placard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2021
Resolved
PAINTS, COATINGS, OR OTHER FLAMABLE OR COMBUSTIBLE PRODUCTS ONBOARD A TOWING VESSEL MUST BE STORED IN A
DESIGNATED STORAGE ROOM OR CABINET WHEN NOT IN USE. FLAMABLE STORAGE CABINET MUST SATISFY UL1275, STROAGE CABINET MUST MEET FM APPROVALS STANDARD 6050.40-B PORTABLE FIRE EXTINGUSIHER MUST BE NEAR THE CABINET.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 27 January 2023
Resolution: Flamable/combustible products were removed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 October 2021
Resolved
EACH TOWING VESSEL MUST BE EQUIPPED WITH A MEANS TO DETECT SMOKE IN THE LOUNGES THAT ALERT INDIVIDUALS IN THOSE SPACES. DETECTOR IN LOUNGE AREA FOUND NOT WORKING.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 28 February 2023
Resolution: Detector installed and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 26 October 2021
Resolved
A REMOTE FUEL SHUT OFF VALVE MUST BE FITTED ON ANY FUEL LINE THAT SUPPLIES FUEL DIRECTLY TO A PROPULSTION ENGINE. VALVE FOUND TO NOT CLOSE ALL THE WAY.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 28 February 2023
Resolution: Tested valve, all was satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 October 2021
Resolved
EACH WATERTIGHT DOORMUST BE MARKED ON BOTH SIDES IN CLEARLY LEGIBLE LETTERS AT LEAST 1” HIGH: “WATERTIGHT DOOR- KEEP CLOSED”. WATER TIGHT DOOR NOT MARKED.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 27 January 2023
Resolution: Door determined not to be watertight but weather tight. Appropriate label was on door.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 26 October 2021
Resolved
EXPOSED HAZARDS SUCH AS ROTATING MACHINERY ARE PROTECTED BY A COVER GUARD OR RAIL. PORTION OF THE PROPELLER SHAFT ARE EXPOSED AND CREATING A SAFETY HAZARD.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 27 January 2023
Resolution: Guard installed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 26 October 2021
Resolved
RAILS OR EQUIVALENT PROTECTION INSTALLED NEAR THE OUTER EDGE OF ALL DECKS ACCESSIBLE TO CREW. AREAS AROUND THE DECK HOUSE WHERE IT WOULD BE REASONABLE DO NOT HAVE A GRAB RAIL INSTALLED
Action required: 60 - Rectify deficiencies prior to movement
Due 26 November 2021
Resolved 27 January 2023
Resolution: Grab rail installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 October 2021
Resolved
EPIRB MUST BE STOWED IN ITS FLOAT FREE BRACKET.HYDROSTATIC RELEASE MARKED WITH EXPIRATION oF 2025, AND SHOULD BE MARKED APRIL 2023, 2 YEARS AFTER INSTALL
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 January 2023
Resolution: Hyrdostatic release marked properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 October 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period [19JUL2021]. This vessel is one of the 75% of the vessels that has not obtained a valid COI. The vessel was not made available for a Coast Guard COI inspection within 90 days of the deadline and the deficiency is now changed to a code 60- rectify deficiencies prior to movement. The vessel is no longer permitted to operate.
Cite: 46 CFR §136.202(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 October 2021
Resolution: Vessel underwent COI inspection. COI is being routed for issuance.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 July 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period [19JUL2021]. This vessel is one of the 75% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Cite: 46 CFR §136.202(a)
Action required: 705 - Other - as specified
Due 21 October 2021
Resolved 17 October 2021