MAURY USCG vessel records Sign in
← All vessels

KEN SIRIUS

KEN SIRIUS is a 2003 freight ship. The Coast Guard has recorded 14 inspections since 2003, most recently in April 2017, along with 4 deficiencies and 2 operational controls.

Records from 2003 to 2017. Most recent: inspection, 25 April 2017.

Built
2003
Last inspected
25 April 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9267900 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
611444
Flag
LIBERIA
—
Maury page id
psix-611444

Inspections, by type

…with no type recorded2
Years with a record 8 calendar years (2003–2017)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it27989 - Convention (Subpart B), Gross Ton
17077 - Convention (Subpart B), Net Ton
58136 - Displacement, Ton
50337 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

25 April 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6129185
17 July 2011 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4085927
16 July 2011 Ballast Water Examination · ISPS I Exam · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4068479
9 July 2011 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4062116
5 December 2009 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3640658
13 November 2008 PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3359588
26 April 2007 Ballast Water Examination · NPV Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2915667
16 September 2006 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2779814
15 January 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2567299
8 January 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2563176
21 July 2005 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2434795
1 February 2005 ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2283838
22 December 2003 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1965121
22 March 2003 Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1762135

Deficiency record · 4

Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 25 April 2017 Resolved
The function of the detection system shall be peridocially tested to the satisfaction of the administration. Vessel's crew cannot provide evidence of a required means of testing the flame detectors. 74SOLAS(01)II-2/13.1.13
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2017
Resolved 26 April 2017
Resolution: Rectified
Fire Fighting › Fire Main › Condition
Issued 25 April 2017 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Four leaks were observed on flange connections on the starboard fire main piping on deck leading to the Bosun Store Room. Continued in narrative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2017
Resolved 26 April 2017
Resolution: Rectified
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 25 April 2017 Resolved
After any survey ogf the ship, no change shall be made in the structural arrangements, machinery, equipment, and other items covered by survey, without the sanction of the Administration. A power cable leading to a replacement port lifeboat battery charger was found to be installed to the emergency switchboard, jeopardixing the integrity of the back stuffing tube. Continued in narrative.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2017
Resolved 26 April 2017
Resolution: Rectified
Fire Fighting › Structural - A Class Divisions › Doors
Issued 16 July 2011 Resolved
0750, All class "A" bulkheads require the doors to be self closing. At least four doors in the galley space listed as clss "A" doors in the fire control plan did not have self closing devices. SOLAS 2001 (cons) CH 11-2/44.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2011
Resolution: Received satisfactory class report and cleared by [name withheld].

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.