HENRY ISLAND

HENRY ISLAND is a 2003 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2003, most recently in April 2026, along with 19 deficiencies.

Records from 2003 to 2026. Most recent: inspection, 23 April 2026.

Built
2003
Last inspected
23 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB4693
611450
Flag
UNITED STATES
367585560
Maury page id
psix-611450

Inspections, by type

Years with a record 21 calendar years (2003–2026)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)67.2 ft × 25.0 ft × 7.0 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)67.2 ft × 25.0 ft × 7.0 ft
ITC tonnageNot recorded
BuilderLATITUDE MARINE · LACONNER · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFRIDAY HARBOR, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG9218MMSI 367585560 · active · compulsorily equipped · granted 2 August 2023, expires 1 August 2033
WDB4693MMSI 366901290 · expired · compulsorily equipped · granted 11 July 2003, cancelled 14 September 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 29

23 April 2026 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8306506
22 April 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8117294
2 May 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7904695
22 April 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7899696
13 February 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7636095
7 April 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7426485
7 April 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7440776
29 March 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7162212
23 March 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7005314
16 March 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6926366
18 June 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6706761
27 March 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6379528
22 March 2018 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6373661
24 March 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6110566
5 April 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5854024
16 March 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5834444
25 March 2014 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4822906
6 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203249
23 March 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3702317
7 December 2009 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3645999
23 March 2009 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3438491
23 April 2008 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3191294
19 March 2008 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3167965
17 July 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2998449
20 September 2006 Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2782007
10 August 2006 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2740142
16 August 2005 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2466273
30 August 2004 Annual Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2201120
16 July 2003 Initial Construction-Excluding Oversight · Inclining Experiment · Deadweight Survey · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1827703

Deficiency record · 19

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 May 2025 Resolved
A vessel over 65 feet in length is required to carry at least three Coast Guard-approved life ring buoys. During the inspection, the marine inspector observed that the grab lines on two of the three life ring buoys, located on the bridge and at the stern, were deteriorated and no longer serviceable. The owner/operator must replace these two life ring buoys with Coast Guard-approved units.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 20 May 2025
Resolution: Owner/operator provided proof via photos of the installed and approved ring buoys.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 2 May 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46CFR199.175(b)(10) or a kit of equivalent contents and instructions. First-aid kit on board found inadequate, missing contents, and expired contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 13 May 2024
Resolution: Verified proper replacement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2023 Resolved
All cable and wire must: (b)(4): Be installed with metal supports spaced not more than 610 mm (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic wire ties must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Vessel did not have metal banding supporting wire runs throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2023
Resolved 9 March 2023
Resolution: Received pictures of metal banding installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2023 Resolved
Electrical equipment exposed to the weather must be watertight. Exterior light housing on forward bulkhead of pilot house was corroded and internal connections were exposed to the environment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2023
Resolved 27 March 2023
Resolution: Received email with picture of new light fixture installed.
Lifesaving › Lifefloat › Serviceable
Issued 22 March 2018 Resolved
Lifefloat in an unserviceable condition. Replace lifefloat. 46CFR180.200
Action required: 705 - Other - as specified
Due 22 April 2018
Resolved 10 April 2018
Resolution: Purchased and installed new life float.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 March 2018 Resolved
Battery in light expired. Replace battery. 46CFR184.726
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 24 March 2018
Resolution: Purchased new battery
Lifesaving › Lifebuoys › Serviceable
Issued 22 March 2018 Resolved
Lifebuoy on stern and lifebuoy outside kpilot house window were unserviceable. Replace lifebuoys. 46CFR180.70
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 29 March 2018
Resolution: Purchased and built up new ring buoys.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 March 2018 Resolved
Battery in light expired. Replace battery. 46CFR185.726
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 24 March 2018
Resolution: Purchased new battery.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 24 March 2017 Resolved
Tubular gauge glasses for diesel fuel tanks made of non-heat resistant plastic tubing. Tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant materials. Replace tubular gauge glasses with heat resistant tubing. 46 CFR 182.440(a)(7)
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 4 April 2017
Resolution: Operator installed correct heat resistant tubing.
Fire Fighting › Fire Hoses › Condition
Issued 24 March 2017 Resolved
Fire hose had pinhole leaks. Each hose must be lined commercial fire hose that conforms to UL19. Remove, destroy, and replace with new hose.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 25 March 2017
Resolution: Operator received and installed new fire hose. All sat.
Fire Fighting › Firemans Outfit › Axe
Issued 20 July 2007 Resolved
No fire axe was located on vessel.
Due 20 August 2007
Resolved 19 August 2007
Resolution: Vsl sent e-mail with order confirmation for fire axe.
Lifesaving › Lifefloat › Paddle
Issued 20 July 2007 Resolved
Paddles were not on board. Need to be placed onboard and attached to life float.
Due 20 August 2007
Resolved 19 August 2007
Resolution: Paddles were purchased and attached to life float; confirmed with e-mailed picture.
Personnel › Training › First Aid/CPR
Issued 20 July 2007 Resolved
Vessel operator did not have current First Aid/CPR cards.
Due 20 August 2007
Resolved 19 August 2007
Resolution: Both captains completed CPR/First Aid course on 19 Aug. Vsl rep to fax current cards to office.
Lifesaving › Hand Flares › Storage
Issued 20 July 2007 Resolved
Flares need to be in labeled container.
Due 20 August 2007
Resolved 19 August 2007
Resolution: Flares placed in labeled, brightly colored container; confirmed with e-mailed picture.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 July 2007 Resolved
Chain on stern deck rail is broken.
Due 20 August 2007
Resolved 19 August 2007
Resolution: Chain fixed on stern deck rail; confirmed with e-mailed picture.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 July 2007 Resolved
Label the location of adult and child lifejackets at entrance of ER.
Due 20 August 2007
Resolved 19 August 2007
Resolution: Vsl rep sent pictures to verify label placed at entrance of the engine room.
Fire Fighting › Ventilation Systems › Fans
Issued 20 July 2007 Resolved
Ventilation at entrance of engine room did not secure.
Due 20 August 2007
Resolved 19 August 2007
Resolution: Vsl rep lubricated hinges on fire/engine room ventilation door; secured successfully.
Engineering › Sea-water System (primary cooling) › Valve
Issued 20 September 2006 Resolved
Valve needs to be moved as close as practicable to the sea chest
Due 22 September 2006
Resolved 25 September 2006
Resolution: Captain sent in pictures of the new valve
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 June 2003 Resolved
Obtain and post a Certificate of Alternative Compliance for vessels navigational lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2003
Resolved 28 September 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.