Records from 2016 to 2026. Most recent: inspection, 23 April 2026.
Documentation record
Registered dimensions (L × B × D)67.2 ft × 25.0 ft × 7.0 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)67.2 ft × 25.0 ft × 7.0 ft
ITC tonnageNot recorded
BuilderLATITUDE MARINE · LACONNER · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFRIDAY HARBOR, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
23 April 2026
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8306506
22 April 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8117294
2 May 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7904695
22 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7899696
13 February 2023
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7636095
7 April 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7426485
7 April 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7440776
29 March 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7162212
23 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7005314
16 March 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6926366
18 June 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6706761
27 March 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6379528
22 March 2018
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6373661
24 March 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6110566
5 April 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5854024
16 March 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5834444
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 May 2025
Resolved
A vessel over 65 feet in length is required to carry at least three Coast Guard-approved life ring buoys. During the inspection, the marine inspector observed that the grab lines on two of the three life ring buoys, located on the bridge and at the stern, were deteriorated and no longer serviceable. The owner/operator must replace these two life ring buoys with Coast Guard-approved units.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 20 May 2025
Resolution: Owner/operator provided proof via photos of the installed and approved ring buoys.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 2 May 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46CFR199.175(b)(10) or a kit of equivalent contents and instructions.
First-aid kit on board found inadequate, missing contents, and expired contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 13 May 2024
Resolution: Verified proper replacement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2023
Resolved
All cable and wire must:
(b)(4): Be installed with metal supports spaced not more than 610 mm (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic wire ties must be limited to bundling or retention of multiple cable installations, and not used as a means of support.
Vessel did not have metal banding supporting wire runs throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2023
Resolved 9 March 2023
Resolution: Received pictures of metal banding installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2023
Resolved
Electrical equipment exposed to the weather must be watertight.
Exterior light housing on forward bulkhead of pilot house was corroded and internal connections were exposed to the environment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2023
Resolved 27 March 2023
Resolution: Received email with picture of new light fixture installed.
Lifesaving › Lifefloat › Serviceable
Issued 22 March 2018
Resolved
Lifefloat in an unserviceable condition. Replace lifefloat. 46CFR180.200
Action required: 705 - Other - as specified
Due 22 April 2018
Resolved 10 April 2018
Resolution: Purchased and installed new life float.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 March 2018
Resolved
Battery in light expired. Replace battery. 46CFR184.726
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 24 March 2018
Resolution: Purchased new battery
Lifesaving › Lifebuoys › Serviceable
Issued 22 March 2018
Resolved
Lifebuoy on stern and lifebuoy outside kpilot house window were unserviceable. Replace lifebuoys. 46CFR180.70
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 29 March 2018
Resolution: Purchased and built up new ring buoys.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 March 2018
Resolved
Battery in light expired. Replace battery. 46CFR185.726
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 24 March 2018
Resolution: Purchased new battery.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 24 March 2017
Resolved
Tubular gauge glasses for diesel fuel tanks made of non-heat resistant plastic tubing. Tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant materials. Replace tubular gauge glasses with heat resistant tubing. 46 CFR 182.440(a)(7)
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 4 April 2017
Resolution: Operator installed correct heat resistant tubing.
Fire Fighting › Fire Hoses › Condition
Issued 24 March 2017
Resolved
Fire hose had pinhole leaks. Each hose must be lined commercial fire hose that conforms to UL19. Remove, destroy, and replace with new hose.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 25 March 2017
Resolution: Operator received and installed new fire hose. All sat.