MAURY USCG vessel records Sign in
← All vessels

PRINS ALEXANDER

PRINS ALEXANDER is a 2002 tank ship. The Coast Guard has recorded 57 inspections since 2003, most recently in June 2020, along with 9 deficiencies and 20 operational controls.

Records from 2003 to 2020. Most recent: inspection, 9 June 2020.

Built
2002
Last inspected
9 June 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9242209 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
611512
Flag
MARSHALL ISLANDS
—
Maury page id
psix-611512

Inspections, by type

…with no type recorded34
Years with a record 11 calendar years (2003–2020)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23948 - Regulatory (Subpart C or D), Gross Ton
23948 - Convention (Subpart B), Gross Ton
7184 - Regulatory (Subpart C or D), Net Ton
7184 - Convention (Subpart B), Net Ton
28095 - Dead Weight, Metric Ton
38795 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 57

9 June 2020 Appeal
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 6972390
3 March 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6919990
6 November 2019 COC-GAS Renew · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6847566
16 October 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6562630
7 September 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6535215
7 September 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6535229
27 August 2018 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6524057
5 April 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6379028
26 March 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6379039
28 February 2018 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6363064
26 January 2018 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6342823
24 January 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6341697
18 May 2017 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6150274
6 May 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6140189
15 April 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6125242
16 March 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6106070
4 March 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6098915
19 February 2017 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6087379
24 October 2016 COE-Offshore
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6027146
24 March 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5839830
24 March 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5839846
19 March 2016 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5850178
20 January 2016 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5799505
17 January 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5798900
21 October 2008 ISPS II Exam · COC-GAS Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3348979
20 October 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3348411
2 January 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3123526
14 November 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3098262
10 November 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3096323
27 July 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3008864
26 July 2007 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3007719
21 June 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2977384
18 June 2007 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2962311
18 June 2007 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2970395
16 June 2007 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2963690
27 March 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2896031
21 February 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2875393
2 August 2006 Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2727356
6 January 2006 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2562437
4 January 2006 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2578595
20 July 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2433402
19 July 2005 COC-GAS Renew · MARPOL Annex I Examination · Ballast Water Examination · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2434089
15 July 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2427482
21 April 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2339753
4 August 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2157753
2 August 2004 NPV Safety Exam · ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2153274
2 August 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2157700
2 August 2004 Type not recorded
No type recorded · GROUP HAMPTON ROADS · USCG East District (CGD-E) · Activity 2162034
2 August 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2168433
8 May 2004 COC-GAS Annual
Type not classified · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2064510
7 May 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2061612
16 October 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1929778
15 October 2003 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1929243
12 October 2003 Security Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1954388
28 May 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1804508
22 May 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1799648
22 May 2003 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1828937

Deficiency record · 9

12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 6 November 2019 Resolved
On ships carrying flammable or toxic products or both, a water spray system for cooling, fire prevention, and crew protection should be installed to cover exposed cargo tank domes, exposed on deck storage vessels, cargo liquid and vapor discharge, and loading manifolds. The system should be capable of covering all areas with a uniformly distributed water-spray. Insufficient water spray coverage was observed over tank dome #1, type "C" tanks 1 and 2 on deck, and both cargo manifolds. A rupture was also observed in the deck water spray piping leading to the port manifold. 74 SOLAS(14)VIII/13.1 IGC Code (1993)11.3.1 and 11.3.2
Action required: 30 - Ship detained
Resolved 8 November 2019
Resolution: Deck water spray system flushed and nozzles cleared. Ruptured section of pipe replaced. System tested satisfactorily.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 November 2019 Resolved
A satellite emergency position-indicating radio beacon shall be capable of transmitting a distress alert. The test feature on the EPIRB was not functional, crew unable to prove proper operation of the EPIRB. 74 SOLAS(14)IV/7.6.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2019
Resolution: Vessel provided satisfactory documentation of new EPIRB delivery
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 6 November 2019 Resolved
Each liferaft shall be stowed with a float-free arrangement. Painter was attached to liferaft cradle and not to the weak link. 74 SOLAS(14)III/13.4.2
Action required: 10 - Deficiency Rectified
Resolved 6 November 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 6 November 2019 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with any additional requirements which may be established by the company. As detailed in the previous deficiencies, objective evidence exists that the vessel is not being maintained in conformity with the provisions of the relevant rules (IGC Code). PSCO noted in review of SMS procedures, the testing of the related cargo systems are contradicted by the condition of systems by the attending [name withheld] verification of the vessel's SMS is required. 74 SOLAS(14)IX/3.1 ISM Code 10.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2019
Resolution: Class conducted targeted audit of maintenance systems on board, ship is conducting corrective actions.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 7 September 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform to the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel does not have a starboard anchor or anchor chain.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 November 2019
Resolution: Vessel has replaced anchor and chain.
Deck/Cargo › Cargo Refrigeration › General
Issued 26 January 2018 Resolved
1825-Spaces in Cargo Area-The doors should be self-closing without any holding back arrangements. The inside air lock door was not self-closing. IGC Code 3.6.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 26 January 2018
Resolution: Door was adjusted so that it was self-closing.
Deck/Cargo › Cargo Stowage › General
Issued 26 January 2018 Resolved
1199-Other(Cargo)-Port deck tank loaded with 718 mm of propane was found leaking from the top of the tank. IGC Code 1.5.3.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 26 January 2018
Resolution: Fitting was tightened on the spot.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 7 May 2004 Resolved
COFR not valid.
Action required: 15 - Rectify deficiencies by next port
Resolved 7 May 2004
Resolution: NPFC verified substantial compliance for COFR#853679-16
Lifesaving › Lifeboat
Issued 15 October 2003 Resolved
Replace/renew lifeboat operating and launching instructions to the satisfaction of class within 30 days
Action required: 705 - Other - as specified
Due 15 November 2003
Resolved 8 May 2004

Ownership record