A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
20 July 2026
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8440472
25 August 2025
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8201945
31 May 2024
COI Inspection · DAPI Audit
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7910111
13 September 2023
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7786924
14 June 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7477932
16 May 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7451738
30 August 2021
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7300633
14 August 2020
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7019985
7 May 2020
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6953062
14 June 2019
DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6648929
30 January 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6600347
29 November 2017
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6314601
31 January 2017
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6080512
29 November 2016
Deficiency Check · Hull Examination · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6041589
8 January 2016
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5793488
9 February 2012
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4241517
27 January 2011
Administrative Inspection · Annual Inspection · Drydock Exam · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3931958
4 February 2010
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3675057
11 May 2009
Administrative Inspection · Welding Related Inspections Qualification Testing
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3472599
4 May 2009
Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3467231
19 March 2009
Deadweight Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3451637
6 January 2009
Annual Inspection · Hull Examination · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3388845
1 February 2008
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3139428
7 June 2007
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2954086
18 January 2007
Construction Oversight · Hull Examination · Simplified Stability Test
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2857774
23 August 2006
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2756506
24 May 2006
Annual Inspection · Simplified Stability Test
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2657426
25 May 2005
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2367842
7 September 2004
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2188779
4 May 2004
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2064635
28 May 2003
Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1804848
28 March 2003
Initial Certification · Plan Review "T" Boat
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1763896
20 March 2003
Plan Review "T" Boat · Construction Oversight · Simplified Stability Test
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1760029
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2021
Resolved
Fuel Shut Off Valves must be installed so as to close against fuel flow. New Outboards and new lines, and company that installed forgot to replace the fuel shut off valves. Install shut off valves per 46 CFR 182.455(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 August 2021
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 August 2021
Resolved
Vessels on river routes must carry 6 approved flares. Vessel has 3 orange smoke, and 3 expired hand red flares. Replace hand red distress signals, and seperate the expired flares from the new flares.
Action required: 10 - Deficiency Rectified
Resolved 30 August 2021
Resolution: provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 August 2021
Resolved
An adult lifejacket must be provided for each person carried on board (vessel certificated for 24 persons). Vessel had on board 22 Type I PFD's. Restricted to no more than 22 passengers until can get 2 more Type I PFD's.
Action required: 10 - Deficiency Rectified
Resolved 30 August 2021
Resolution: provided
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 June 2019
Resolved
Provide means to leave passenger count ashore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2019
Resolved 28 June 2019
Resolution: Slipaway River Tours uses a widget/app, they update this and it gets sent to different people.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 June 2019
Resolved
Provide aspirin for 1st Aid Kit
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 21 June 2019
Resolution: provided
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 June 2019
Resolved
Provide eye wash for 1st aid kit
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 21 June 2019
Resolution: provided
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 June 2019
Resolved
Provide a copy of the Coast Pilot for area of operation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 19 June 2019
Resolution: provided
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 June 2019
Resolved
Provide copy of light list for area of operation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 19 June 2019
Resolution: provided
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2019
Resolved
Provide 3-2.5gallon fire buckets, and label.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2019
Resolved 21 June 2019
Resolution: provided
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 June 2019
Resolved
Provide Type II retro-reflective material on RLB.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2019
Resolved 28 June 2019
Resolution: provided and completed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2019
Resolved
Provide copy of last pre-employment test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 19 June 2019
Resolution: provided 2 pre-emplyments and one random
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2019
Resolved
Provide means for post casualty testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 27 June 2019
Resolution: provided by Drug Consortium
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2019
Resolved
Post EAP number
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 21 June 2019
Resolution: posted
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2019
Resolved
Complete 1 hour supervisory training for DAPI
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 28 June 2019
Resolution: completed, consortium sent on a flash drive
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 January 2018
Resolved
Missing Ammonia inhalants, provide Ammonia inhalants to the satisfaction of attending marine inspector. 46CFR160.041-4(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 15 January 2018
Resolution: Deficiency cleared, new Ammonia inhalants provided exp: 11/21
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 February 2017
Resolved
Install lock washers or lock nuts on battery cable connections. 46CFR183.340
Due 2 March 2017
Resolved 28 February 2017
Resolution: Lock nuts installed on battery cables to terminals.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 February 2017
Resolved
Remove or cap dead-end wire under operation station. 46CFR183.200 (G)(C)
Due 2 March 2017
Resolved 28 February 2017
Resolution: Dead end wire removed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 February 2017
Resolved
Replace grab line on ring life buoy. 46CFR180.70
Due 2 March 2017
Resolved 28 February 2017
Resolution: Entire life buoy replaced with approved type.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 February 2017
Resolved
Lable type and quantity of each storage area for life jackets. 46CFR185.604(F)
Due 2 March 2017
Resolved 28 February 2017
Resolution: Life jacket stowage areas properly labeled IAW regulations.
Navigation › Piloting/Steering › Marine Charts
Issued 16 February 2017
Resolved
Provide updated chart for area of operation. 46CFR184.420
Due 2 March 2017
Resolved 28 February 2017
Resolution: New chart provided for operating area.
Fire Fighting › Fire Bucket › Stenciling
Issued 16 February 2017
Resolved
Re-label 1 fire bucket. 46CFR181.610
Due 2 March 2017
Resolved 28 February 2017
Resolution: Fire bucket relabeled properly.
Construction/Loadline › Structures › Superstructure
Issued 5 January 2017
Resolved
Repair three cracks starboard side at top of canopy frame near operating station iaw 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 19 January 2017
Resolved 28 February 2017
Resolution: Cracked welds satisfactorily repaired in all locations.
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 January 2016
Resolved
Unable to perform drills without proper Master's License onboard IAW 46 CFR 185.525.
Action required: 705 - Other - as specified
Due 19 January 2016
Resolved 19 January 2016
Resolution: Conducted drills sufficiently.
Lifesaving › Lifebuoys › Serviceable
Issued 27 January 2011
Resolved
REPAIR/REPLACE LIFERING TO BE SERVICEABLE AS PER 46 CFR 180.70
Due 2 February 2011
Resolved 31 January 2011
Resolution: Replaced lifering with new.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 27 January 2011
Resolved
REPAIR/REPLACE LIGHT FLOAT TO BE SERVICEABLE AS PER 46 CFR 180.70
Due 2 February 2011
Resolved 31 January 2011
Resolution: Replaced light float with new.
Fire Fighting › Fire Bucket › Availability
Issued 4 February 2010
Resolved
Provide a labeled fire bucket with lanyard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 2 March 2010
Resolution: Provided proof of new fire bucket.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 February 2010
Resolved
Renew battery in lifebuoy waterlight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 2 March 2010
Resolution: Provided proof of new battery for waterlight.
Navigation › Piloting/Steering › Marine Charts
Issued 4 February 2010
Resolved
Provide up to date chart of area navigated.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 2 March 2010
Resolution: Provided proof of new navigational chart for area.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 February 2010
Resolved
Enclose railing courses aft of operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 2 March 2010
Resolution: Provided proof of cleared deficiency.
Communications › Visual Communication › Signalling Lamp
Issued 4 February 2010
Resolved
Provide a second flashlight on board vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 2 March 2010
Resolution: Provided proof of cleared deficiency.
Engineering › Fuel Oil Service System › Hose
Issued 8 June 2007
Resolved
INSTALL USCG APPROVED HOSE IN FUEL SYSTEM SUPPLY TO OUTBOARD ENGINES FROM FILTERS.
Due 22 June 2007
Resolved 20 July 2007
Resolution: Fuel hoses were replaced.
Engineering › Gasoline Engine (propulsion) › Valve, Reed (2 stroke)
Issued 8 June 2007
Resolved
INSTALL RPM GAUGES AT THE OPERATING STATION FOR BOTH OUTBOARD ENGINES.
Due 6 July 2007
Resolved 20 July 2007
Resolution: RPM gauges were installed.
Operations/Management › Drug and Alcohol Testing
Issued 28 March 2003
Resolved
Provide documentation that the Drug and Alcohol Program meets 46CFR Part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2003
Personnel › Certificates/Documents/Licenses
Issued 28 March 2003
Resolved
Provide original Masters license onboard vessel as per 46CFR185.402 LEGACY COMPONENT DESC: License, Master
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2003
Documentation › Manuals/Policy Documentation
Issued 28 March 2003
Resolved
Provide an Emergency List onboard vessel as per 46CFR185.510 LEGACY COMPONENT DESC: Emergency Instructions
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2003
Lifesaving › Visual Distress Signals (General)
Issued 28 March 2003
Resolved
Provide 2 additional orange smoke signals as per 46CFR180.68 LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2003
Engineering › Bilge Water Management System
Issued 28 March 2003
Resolved
Provide proper portable bilge pump as per 46CFR182.520(b). LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2003
Electrical › Electric Supply System (service)
Issued 28 March 2003
Resolved
Provide a proper battery charger w/amp meter for 12v ships service battery as per 46CFR183.350 LEGACY COMPONENT DESC: Battery Charger
Due 26 April 2003
Resolved 14 April 2003
Electrical › Electric Supply System (service)
Issued 28 March 2003
Resolved
Provide required Electrical Drawings for approval as per 46CFR Subpart B-Plans (b) (4) (i) (ii) (iii) (vi) (vii) (viii).
Due 26 April 2003
Resolved 14 April 2003