Professional
The full record for this vessel
Behind this panel: 7 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 7
24 October 2025
PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8250765
2 September 2024
COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7984823
7 July 2023
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7721569
1 March 2022
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7403725
2 December 2021
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7353536
23 October 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6027883
5 May 2016
ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5869723
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 October 2025
Resolved
Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products.
PSCO observed exposed wiring on valve position indicators on #4 tank top, #3 tank top, #2 tank top, and #1 tank top. Additionally PSCO observed exposed wiring on port and starboard manifold valves. PSCO observed exposed wiring and missing plugs on lights for fwd life raft and midship stores.
74 SOLAS (20)VII / 13.1
93 IGC
10.1.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2025
Resolution: Received class report attesting to repairs to electrical on deck. See documents.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 7 July 2023
Resolved
The pressure relieving system should consist of an arrangement that should include fusible sensors that cause the relief valave to become operable. Tanks #1 and 2 had paint/rubber cement covering their fusible plugs.
74 SOLAS (20) VII/13.1
IGC CODE(93) 11.3.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2023
Resolved 9 July 2023
Resolution: Rectification received and approved by Flag and Class.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 7 July 2023
Resolved
A WATER SPRAY SYSTEM FOR COOLING, FIRE PREVENTION AND CREW PROTECTION SHOULD BE PROVIDED TO COVER EXPOSED CARGO TANK DOMES. PSCO OBSERVED CARGO TANK #3 NOT SUCCESSFUL COVERED DUE TO CLOGGED NOZZLES.
74 SOLAS (2) VII/13.1
IGC CODE (93) 11.3.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 July 2023
Resolved 7 July 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 December 2021
Resolved
Electrical installations should be such as to minimize the risk of fire and explosion from flammable products. Multiple wires to lighting fixtures in the motor room are missing protective coverings and showing signs of cracking and corrosion. 74SOLAS2020 VII/13.1 - IGC Code (1993)10.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2021
Resolution: Rina class attested to the repairs being made and inspected satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 December 2021
Resolved
All pipes in the water-spray system should be resistant to corrosion by seawater. PSCOs witnessed one pin hole leak and one soft patch on the deck spray piping which protects cargo tank #3. 74SOLAS2020 VII/13.1 - IGC Code (1993)11.3.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2021
Resolution: Deck spray piping has been repaired and tested to satisfaction of class.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 2 December 2021
Resolved
Information should be onboard and available to all concerned, giving the necessary data for the safe carriage of cargo. Cargo ops manual references flow failure alarm for fixed gas detection system, which is not actually present on the panel or the fixed gas detection manual. 74SOLAS2020 VII/13.1 - IGC Code (1993)18.1.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 December 2021
Resolution: Vessel DPA and onboard surveyor submitted a Management of Change form and corrected the manuals to align with the system onboard.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. WB 1 Port sounding pipe was corroded and could lead to potential water ingress. 74SOLAS2020 I/11
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 December 2021
Resolution: Sounding pipe was repairs and inspected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 December 2021
Resolved
All gasketed pipe joints and hose connections should be electrically bonded. Bonding strap for #1 mast riser was corroded and broken. 74SOLAS2020 VII/13.1 - IGC Code (1993)5.2.1.4
Action required: 10 - Deficiency Rectified
Resolved 2 December 2021
Resolution: Bonding strap replaced.
Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 5 May 2016
Resolved
74SOLAS(14)I/11(a): Condition of the ship/ equipment shall be maintained to conform w/ provisions of present regs to ensure that ship in all respects will remain fit to proceed to sea w/o danger to ship/ persons onboard. A temp anti-vibration support was discovered IVO compressor #1 (stbd). Additionally there were 3 smaller supports foudn IVO of the remaining 3 compressors as well as steel cables.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 6 May 2016
Resolution: Received Class [name withheld] attesting to the structural integrity of anti-vibration supports iwo cargo compressors.