Records in 2020. Most recent: operational control imposed, 12 August 2020.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 12 August 2020
Resolved
THE COMPANY SHOULD ENSURE THAT INSPECTIONS ARE HELD AT APPROPRIATE INTERVALS; ANY NON-CONFORMITY IS REPORTED, WITH ITS POSSIBLE CAUSE, IF KNOWN; APPROPRIATE CORRECTIVE ACTION IS TAKEN; AND RECORDS OF THESE ACTIVITIES ARE MAINTAINED. A REVIEW OF THE VESSEL'S SAFETY MANAGEMENT SYSTEM DURING AN EXPANDED EXAM REVEALED THE VESSEL FAILED TO CONDUCT OR DOCUMENT REQUIRED CRITICAL EQUIPMENT AND SYSTEMS STATUS TESTING AT THE APPROPRIATE INTERVALS AS STATED ON FORM E35. ADDITIONALLY, LONG STANDING NONCONFORMITIES IDENTIFIED THROUGHOUT THE ENGINE ROOM WERE NOT REPORTED TO THE COMPANY AS STATED IN CHAPTER 9 OF THE VESSEL'S SMS. RECOMMEND EXTERNAL SMS AUDIT. 74SOLAS(14) IX/3, ISM CODE 10.2, 30ABC
Action required: 30 - Ship detained
Resolved 14 August 2020
Resolution: Vessel had ISM audit conducted. See attached document for additional information.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 August 2020
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO'S IDENTIFIED EXCESSIVE OIL ACCUMULATION AND OIL SOAKED RAGS THROUGHOUT THE ENGINE ROOM TO INCLUDE: BETWEEN AND BELOW THE DIESEL OIL AND HFO SETTLING TANKS FROM AN UNKNOWN OIL SPILL, PURIFIER FLATS, UNDER ALL THREE GENERATORS, AT THE FUEL OIL TRANSFER PUMP, AND UNDER BOTH AIR COMPRESSORS CREATING A SIGNIFICANT FIRE HAZARD. 74 SOLAS (14) I/11, 30 ABC
Action required: 30 - Ship detained
Resolved 14 August 2020
Resolution: All oil acculumation and oil soaked rags were cleaned from engine room. Verified through folow up exam and class/flag report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 August 2020
Resolved
IN A SHIP IN WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO'S IDENTIFIED AN ACTIVE FUEL OIL LEAK ON THE NO.2 GENERATOR FUEL OIL LEAK ALARM RESERVOIR CREATING A FIRE HAZARD AND BRINGING THE OPERABILITY OF THE ALARM INTO QUESTION. THE RESERVOIR WOULD FAIL TO FILL AND SET OFF THE ALARM IN AN EMERGENCY DUE TO THE LEAK. 74SOLAS(01)II-2/15, 30ABC
Action required: 30 - Ship detained
Resolved 14 August 2020
Resolution: Crew dismantled reservoir and thoroughly cleaned it including clogged overflow drain tubing. Sensor was reassembled and tested with satisfactory results. Verified during follow up exam and class/flag report.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 12 August 2020
Resolved
PHYSICAL CONDITION AND PROPER STORAGE OF MOORING LINES AND ROPES TO ENSURE THAT THEY ARE FREE OF DAMAGE AND DEFECTS AND ARE NOT EXPOSED TO CONDITIONS WHICH COULD LEAD TO THEIR DETERIORATION AND EVENTUAL FAILURE. PSCO'S OBSERVED A SPLICE IN AFT MOORING LINE, LEADING TO QUESTIONABLE INTEGRITY OF LINE. ILO-147/PWSA, 46USC70002, 60C
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 August 2020
Resolution: Received and reviewed photos and facility attestation that the compromised mooring line was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2020
Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO'S IDENTIFIED ACTIVE JACKET WATER LEAKS ON MAIN ENGINE CYLINDERS #2 AND #3. 74SOLAS(04)II-1/26.1, 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2020
Resolution: Crew tightened upper connecting cooling ring to the cylinder head. Condition of class was given to have the connecting rings renewed at a later date. Verified during follow up examination and class report.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 12 August 2020
Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9 OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED IN THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO'S IDENTIFIED SPLICED ELECTRIC CABLE ON #2 BATTERY BANK AND LOOSE CABLE CONNECTION ON BATTERY BANK #1 FOR EMERGENCY GENERATOR. 74SOLAS(14) I/11B, 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2020
Resolution: Spliced serial connecting cable was replaced with new cable. All connections were greased and tightened. Verified during follow up examination and class report.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 12 August 2020
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO'S IDENTIFIED SEVERAL ELECTRICAL SPLICES IN VICINITY OF THE BURNER ASSEMBLY OF THE INCINCERATOR. ADDITIONALLY, THE INCINERATOR DOORS HAD MISSING INSULATION AND WARPED/WASTED SEALS. 74SOLAS(14) I/11A, 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2020
Resolution: Exposed cables were properly stowed in junction boxes. Doors refractory were repaired and missing insulation and sealing arrangements were refurbished. Verified during follow up exam and class report.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 August 2020
Resolved
THE PROVISION OF SAFE MEANS OF ACCESS TO AND THROUGHOUT THE SHIP, AND THE SATISFACTORY PHYSICAL CONDITION OF LADDERS, DECKS, BULWARKS, FENCING, HANDRAILS, ETC. PSCO'S IDENTIFIED SEVERED SUPPORT BEAMS FOR A WALKWAY AND STAIRS IN THE VICINITY OF THE MAIN ENGINE. ADDITIONALLY, SEVERAL DECKPLATE COVERS WERE NOT IN PLACE ON THE LOWEST ENGINE ROOM DECK AND A DECKPLATE NEAR THE MAIN ENGINE LOCAL CONTROLS WAS WASTED WITH SHARP METAL EDGES PROTRUDING UPWARDS. ILO-147/PWSA 46 USC 70002, 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2020
Resolution: Supporting structure for main engine port side walkway was disconnected, properly aligned, and properly welded. Verified during follow up exam and class report.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 12 August 2020
No resolution recorded
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO'S IDENTIFIED NUMEROUS PINHOLE LEAKS IN SEWAGE PIPING AROUND THE MARINE SANITATION DEVICE. 74SOLAS(14) I/11A, 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2020 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 August 2020
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO'S IDENTIFIED ACTIVE LEAK FROM CASCADE TANK FLANGE IN THE VICINITY OF INSPECTION PORT. 74SOLAS(14) I/11A, 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2020
Resolved 17 August 2020
Resolution: New gasket was installed with new bolts. No leaking observed during follow up exam. See class Report.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 12 August 2020
No resolution recorded
FOLLOWING INSTALLATION, THE MASTER, OWNER, OPERATOR, AGENT OR PERSON IN CHARGE OF THE VESSEL MUST PROPERLY MAINTAIN THE BALLAST WATER MANAGEMENT SYSTEM IN ACCORDANCE WITH ALL MANUFACTURER SPECIFICATIONS. VESSEL'S BALLAST WATER MANAGEMENT SYSTEM WAS FOUND TO BE INOPERABLE. 33CFR151.2025A1, 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign