Records from 2003 to 2025. Most recent: inspection, 30 September 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 30
30 September 2025
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8244341
14 March 2025
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8093711
10 February 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8077409
5 February 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7860866
16 February 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7641387
30 January 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7629186
30 December 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7614444
6 October 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7636378
18 January 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7387117
14 December 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7111736
2 December 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7105088
9 November 2020
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7092437
30 October 2020
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7087121
7 February 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6904742
27 November 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6867706
5 December 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6592452
27 November 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6313086
7 December 2016
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6054711
30 November 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6049682
22 November 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6045958
17 November 2015
COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5758861
19 September 2015
Type not recorded
No type recorded · Station Annapolis · USCG East District (CGD-E) · Activity 5724178
20 December 2011
In-Service Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4212533
9 December 2010
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3908055
24 November 2010
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3900136
20 September 2010
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3853402
16 July 2008
Hull Examination · Damage Survey · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3269995
2 October 2007
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3071331
12 July 2006
Simplified Stability Test · Initial Certification · Plan Review "T" Boat · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2710342
22 April 2003
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1778245
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 30 September 2025
No resolution recorded
11127 - The color of the buoyant apparatus must be primarily vivid reddish orange as defined by sections 13 and 14 of FED-STD-595C. The top of the life float is no longer reddish orange.
46 CFR 180.200(a)(2)
46 CFR 160.010-4(n)
Action required: 16 - Rectify deficiencies w/in 14 days
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 30 September 2025
No resolution recorded
11127 - Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. The retroreflective tape on the life float was deteriorated.
46 CFR 180.200(a)(2)
46 CFR 160.010(p)
Action required: 16 - Rectify deficiencies w/in 14 days
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 30 September 2025
No resolution recorded
11127 - The name of a vessel must be marked or painted in clearly legible letters and numbers on each life float. The name was faded off the life float.
46 CFR 185.604(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2025
No resolution recorded
11118 - Each life jacket must be marked with Type I retroreflective material. Multiple life jackets had deteriorated retroreflective tape.
46 CFR 185.604(h)
Action required: 16 - Rectify deficiencies w/in 14 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 February 2025
Resolved
13101 - Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. When the propulsion was tested on the vessel water was streaming from the shaft seal.
46 CFR 182.200
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 March 2025
Resolution: Vessel owner provided video showing the shaft was no longer leaking.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 December 2022
Resolved
The owner or managing operator shall make a vessel available for drydock examinations and internal structural examinations. A vessel that is exposed to brackish water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every three years.
Vessel Owner/operator failed to completed required Drydock and internal structural exam by their required dates of November 30, 2022.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2023
Resolution: Completed vessel dry dock on 30JAN2023.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 November 2020
Resolved
At least one ring life buoy must be fitted with a lifeline. Attending MI observed deteriorated, unserviceable ring life buoy on board at time of inspection.
46CFR180.70(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2020
Resolution: Received photographic evidence of new ring life buoy installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 November 2020
Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. MI observed flame screen bowl missing from fuel filter.
46CFR182.455(b)(6)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 November 2020
Resolution: Received photographic evidence of new flame screen bowl fitted on fuel filter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 November 2020
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Coupling attached to fuel shutoff valve was wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2020
Resolved 2 December 2020
Resolution: Vessel representative provided satisfactory photographic evidence of replacement coupling attached to fuel shutoff valve.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 November 2020
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. Alcohol testing strips found on board were expired at time of inspection.
46CFR16.240
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 14 December 2020
Resolution: Photographic evidence of valid alcohol testing strips provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 November 2020
Resolved
There must be a means of accurately determining the amount of fuel in each fuel tank either by sounding, through a separate sounding pipe or a fill pipe, or by an installed marine type fuel gauge. Sole means of determining fuel quantity, fuel gauge at operating station, was inoperable at time of inspection.
46CFR182.445(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 2 December 2020
Resolution: Vessel representative provided satisfactory photographic evidence of working fuel gauge as well as renewed wiring.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 February 2020
Resolved
Vessel's starboard navigation light was dim outside of standards set forth in 33CFR83.22.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2020
Resolved 29 April 2020
Resolution: Light bulb replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 February 2020
Resolved
Life floats must be fitted with a floating waterlight. It must be attached around the body of the life float by a 3/8" lanyard, resistant to deterioration from UV light, and 18 ft in length. Vessel's lanyard was 12 ft
long. Replace lanyard to standard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2020
Resolved 29 April 2020
Resolution: New lanyard installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 February 2020
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date charts and publications.
All publications found to be out of date except NAV Rules.
Update all required navigational publications with the
exception of NAV Rules.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2020
Resolved 29 April 2020
Resolution: New publications procured.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 30 November 2016
Resolved
Provide proof of operational Fireboy, including in “over-ride” mode.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 December 2016
Resolved 7 December 2016
Resolution: Repaired/Corrected.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 November 2016
Resolved
Repair discrepant electrical outlet located in the forward /compartment on the Starboard/Aft bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 December 2016
Resolved 7 December 2016
Resolution: Renewed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 November 2016
Resolved
Conduct U/W Drills as part of the Tier 2 Annual Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 December 2016
Resolved 7 December 2016
Resolution: Satisfactory drills conducted.
Lifesaving › Buoyant Apparatus › Marking
Issued 17 November 2015
Resolved
Life float, life jackets and life ring are mislabeled; they are currently labeled with incorrect vessel name (46CFR185.604),
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2015
Resolved 22 November 2016
Resolution: Attended vessel and cleared above deficiency.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 November 2015
Resolved
Lanyard for life ring’s light is improperly attached to the body of the life ring (46CFR180.70 (d)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2015
Resolved 22 November 2016
Resolution: Attended vessel and cleared above deficiency.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 November 2015
Resolved
Existing Currents Table manual is out-of-date 46CFR184.420 (a)(5)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2015
Resolved 22 November 2016
Resolution: Attended vessel and cleared above deficiency.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 17 November 2015
Resolved
Incorrect vessel name located on the stern of the vessel (46CFR67.123 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2015
Resolved 22 November 2016
Resolution: Attended vessel and cleared above deficiency.
Documentation › Certificates/Documents › FCC SSL
Issued 17 November 2015
Resolved
Vessel needs FCC Station License (47CFR80.13).
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2015
Resolved 22 November 2016
Resolution: Attended vessel and cleared above deficiency.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 November 2015
Resolved
Provide eye wash for first aid kit (46CFR160.041).
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2015
Resolved 22 November 2016
Resolution: Attended vessel and cleared above deficiency.
Documentation › Certificates/Documents › FCC SSL
Issued 9 December 2010
Resolved
Provide proof of marine operators permit.
Due 16 December 2010
Resolved 7 November 2011
Resolution: Recieved copy of M.R.O.P. via e-mail, sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 December 2010
Resolved
Repair or replace ringbuoy waterlight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Engineering › Bilge Water Management System › Not Operational
Issued 9 December 2010
Resolved
Repair or replace automatic bilge function for steering compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Communications › Alarms/Indicators › High Water Alarm
Issued 9 December 2010
Resolved
Repair or replace high water alarm in engine bay.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2010
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 July 2008
Resolved
Provide onboard current alcohol test kits for al crew members.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 16 July 2008
Resolution: New alcohol test kits were in main office and placed onboard prior to departure,
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 July 2008
Resolved
Replace expired asprin and eyewash for first aid kit.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 21 July 2008
Resolution: Received a call from the O/Op stating that the asprin and the eyewash for the first aid kit have been replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Approval
Issued 16 July 2008
Resolved
All portable fire extinguishers and fixed fire boy system are out of service date. Prior to carrying passengers for hire have all equipment serviced and approved by attending marine inspector. Fire boy system operated properly when tested.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2008
Resolved 17 July 2008
Resolution: Received a fax receipt of the servicing of the fixed and portable fire extinguishing systems.
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 October 2007
Resolved
Visual indicator for No. 3 bilge pump not operating, repair/replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2007
Resolved 30 October 2007
Resolution: Received fax from O/Op attesting to the replacement of the item above.
Lifesaving › Lifefloat › Retroreflective Material
Issued 2 October 2007
Resolved
Provide retroreflective tape on life float.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2007
Resolved 30 October 2007
Resolution: Received fax from O/Op attesting to the purchase of the item above.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 2 October 2007
Resolved
Replace expired hydostatic release prior to operating Limited Coastwise and nlt 02 Nov 07.
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 30 October 2007
Resolution: Received fax from O/Op attesting to the replacement of the item above