BELLEVUE

Built
2003
Last inspected
18 November 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 18 November 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 14 calendar years (2008–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH7925
612179
Flag
UNITED STATES
Maury page id
psix-612179

Documentation record

Registered dimensions (L × B × D)56.0 ft × 22.0 ft × 7.5 ft
Registered tonnagegross 61 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE BUILDERS INC · UTICA, IN, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCOVINGTON, KY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 7 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Simplified, Gross Ton
49 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 11 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 11

Inspection history · 18

18 November 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8270423
4 January 2025 Damage Survey · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8057507
4 January 2025 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8072256
15 October 2024 COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8019106
27 November 2023 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7818581
1 November 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7590473
18 November 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7353455
14 April 2021 Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7175113
11 November 2020 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7084503
15 October 2019 MTSA Verification · Initial Certification · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6834568
19 April 2017 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6128093
27 March 2015 DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5092851
9 February 2015 Administration · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5071903
11 January 2013 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4517702
6 October 2012 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4469556
2 March 2011 DAPI Audit · MTSA Verification · Administration · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3955844
23 February 2010 Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3685905
12 May 2008 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3205360

Deficiency record · 18

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 November 2025 Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, must be inspected or tested at least once every 12 months. Maintenance not conducted by a cerftified person per NFPA 10.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2025
Resolution: O/O provided Cert. for indiviual conducting inspection/ exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 January 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2025
Resolution: Found clogged fuel filter. Replaced filter, ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 November 2022 Resolved
System missing layout schematic, activation lever located in Egine room, pull station cover missing.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2022
Resolved 22 November 2022
Resolution: Operator provided objective evidence showing updated location of remote activation lever with new cover installed.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 1 November 2022 Resolved
Crew was unfamiliar with activating system at the local area in the vicinity of agent bottles. Provide proof of training.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2022
Resolved 22 November 2022
Resolution: Operator provided objective evidence of documented training along with updated system operation activation directions and schematics.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 18 November 2021 Resolved
Type II MSD did not have operating placard/instructions posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 November 2021 Resolved
No batteries in ring buoy foot lights (pilot house) port Starboard - corrected on the spot
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 December 2021
Resolved 18 November 2021
Resolution: Batteries were replaced , to the satisfaction of the Coast Guard
08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 November 2021 Resolved
General alarm light not working in lower engine room
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 November 2021 Resolved
Expired items in first aid kit on 2nd deck, replace with up to date first aid items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 November 2021 Resolved
STBD Generator visual low level alarm stayed on while the generator was under load and while offline, indicator light in pilot house stayed on, need to identify as to why the generator was giving false alarms.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 November 2021 Resolved
Forward STBD emergency hatches gasket to the lower engine room leaking excessively, repair/replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2021 Resolved
Vessel stores gasoline in port tow knee, does not have a B:40 extinguisher within the vicinity, recommend moving gas container to proper flame locker on stern or add additional B:40 extinguisher near the tow knee.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 November 2021 Resolved
Excess water was in the battery boxes to the PORT MDE – corrected on the spot
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 18 November 2021
Resolution: Drained all the water out o the satisfaction of the Coast Guard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 November 2021 Resolved
Excess water coming in from STBD shaft packing, repair/replace shaft packing to reasonable amount of water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 18 November 2021 Resolved
Exhaust lagging on both port and starboard generator exhaust not fully wrapped around exhaust, install additional lagging to prevent burn hazard
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 October 2019 Resolved
All piping, controls, valves, and alarms must be inspected; and the operation of controls for each fixed fire-extinguishing system and detecting system must be tested, to determine that the system is operating properly. MI noted release solenoid on top of FM-200 Bottle was loose and not properly attached.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2019
Resolved 19 November 2019
Resolution: Fire System servicing company arrived onboard and tightened solenoid and sttested to proper operation of system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2019 Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet; Vessel stores gas cans in STBD Tow knee which has been designated as Flammable Storage Locker and does not have extinguisher in the vicinity.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 27 November 2019
Resolution: Vessel has proper extinguisher installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2019 Resolved
Fire hose must be a lined commercial fire hose 15 meters (50 feet) in length; Vessel's hose is >50 ft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 27 November 2019
Resolution: Company installed 50 ft. fire hose
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 October 2019 Resolved
All seals and gaskets must be properly maintained to prevent leaks of combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space; Both generators are showing signs of seepage from rear seals.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 25 November 2019
Resolution: Received tech report certifying rear main seals replacement and generator cleaning.