Documentation record
Registered dimensions (L × B × D)56.0 ft × 22.0 ft × 7.5 ft
Registered tonnagegross 61 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE BUILDERS INC · UTICA, IN, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCOVINGTON, KY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 7 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Simplified, Gross Ton
49 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
18 November 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8270423
4 January 2025
Damage Survey · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8057507
4 January 2025
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8072256
15 October 2024
COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 8019106
27 November 2023
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7818581
1 November 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7590473
18 November 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7353455
14 April 2021
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 7175113
11 November 2020
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7084503
15 October 2019
MTSA Verification · Initial Certification · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6834568
19 April 2017
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6128093
27 March 2015
DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5092851
9 February 2015
Administration · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5071903
11 January 2013
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4517702
6 October 2012
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4469556
2 March 2011
DAPI Audit · MTSA Verification · Administration · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3955844
23 February 2010
Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3685905
12 May 2008
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3205360
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 November 2025
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, must be inspected or tested at least once every 12 months. Maintenance not conducted by a cerftified person per NFPA 10.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 December 2025
Resolution: O/O provided Cert. for indiviual conducting inspection/ exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 January 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 January 2025
Resolution: Found clogged fuel filter. Replaced filter, ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 November 2022
Resolved
System missing layout schematic, activation lever located in Egine room, pull station cover missing.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2022
Resolved 22 November 2022
Resolution: Operator provided objective evidence showing updated location of remote activation lever with new cover installed.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 1 November 2022
Resolved
Crew was unfamiliar with activating system at the local area in the vicinity of agent bottles. Provide proof of training.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2022
Resolved 22 November 2022
Resolution: Operator provided objective evidence of documented training along with updated system operation activation directions and schematics.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 18 November 2021
Resolved
Type II MSD did not have operating placard/instructions posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 November 2021
Resolved
No batteries in ring buoy foot lights (pilot house) port Starboard - corrected on the spot
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 December 2021
Resolved 18 November 2021
Resolution: Batteries were replaced , to the satisfaction of the Coast Guard
08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 November 2021
Resolved
General alarm light not working in lower engine room
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 November 2021
Resolved
Expired items in first aid kit on 2nd deck, replace with up to date first aid items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 November 2021
Resolved
STBD Generator visual low level alarm stayed on while the generator was under load and while offline, indicator light in pilot house stayed on, need to identify as to why the generator was giving false alarms.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 November 2021
Resolved
Forward STBD emergency hatches gasket to the lower engine room leaking excessively, repair/replace gasket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2021
Resolved
Vessel stores gasoline in port tow knee, does not have a B:40 extinguisher within the vicinity, recommend moving gas container to proper flame locker on stern or add additional B:40 extinguisher near the tow knee.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 November 2021
Resolved
Excess water was in the battery boxes to the PORT MDE – corrected on the spot
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 18 November 2021
Resolution: Drained all the water out o the satisfaction of the Coast Guard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 November 2021
Resolved
Excess water coming in from STBD shaft packing, repair/replace shaft packing to reasonable amount of water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 18 November 2021
Resolved
Exhaust lagging on both port and starboard generator exhaust not fully wrapped around exhaust, install additional lagging to prevent burn hazard
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2021
Resolved 13 December 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 October 2019
Resolved
All piping, controls, valves, and alarms must be inspected; and the operation of controls for each fixed fire-extinguishing system and detecting system must be tested, to determine that the system is operating properly. MI noted release solenoid on top of FM-200 Bottle was loose and not properly attached.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 November 2019
Resolved 19 November 2019
Resolution: Fire System servicing company arrived onboard and tightened solenoid and sttested to proper operation of system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2019
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet; Vessel stores gas cans in STBD Tow knee which has been designated as Flammable Storage Locker and does not have extinguisher in the vicinity.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 27 November 2019
Resolution: Vessel has proper extinguisher installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2019
Resolved
Fire hose must be a lined commercial fire hose 15 meters (50 feet) in length; Vessel's hose is >50 ft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2019
Resolved 27 November 2019
Resolution: Company installed 50 ft. fire hose
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 October 2019
Resolved
All seals and gaskets must be properly maintained to prevent leaks of combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space; Both generators are showing signs of seepage from rear seals.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 25 November 2019
Resolution: Received tech report certifying rear main seals replacement and generator cleaning.