AMERICAN DREAM II
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named AMERICAN DREAM II
AMERICAN DREAM II is a 2003 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2003, most recently in February 2026, along with 34 deficiencies and 1 operational control.
Records from 2003 to 2026. Most recent: inspection, 24 February 2026.
- Built
- 2003
- Last inspected
- 24 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 34 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1139254
WDI6202
612394
Flag
UNITED STATES
368475270
Maury page id
psix-612394
Inspections, by type
…with no type recorded1
Years with a record
20 calendar years (2003–2026)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFORT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 9 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ9904MMSI 368475270 · active · compulsorily equipped · granted 20 May 2026, expires 20 May 2036
WDI6202MMSI 369256000 · expired · compulsorily equipped · granted 19 February 2016, cancelled 25 April 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDB3424MMSI 369256000 · expired · compulsorily equipped · granted 29 March 2003, cancelled 1 June 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 30
24 February 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8314845
15 May 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8135708
26 June 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7942722
27 February 2024
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7871398
5 April 2023
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7660202
27 April 2022
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7439320
16 March 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7414023
14 March 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7411201
1 July 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7241432
6 October 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7072185
25 February 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6915069
14 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6683601
12 April 2018
COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6388044
2 February 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6348495
20 June 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6181059
6 June 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5898658
21 March 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5837517
25 June 2014
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4898353
25 March 2014
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4821663
12 June 2012
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4334878
10 December 2011
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 4206206
10 April 2008
Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3181198
1 April 2008
Deficiency Check · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3174685
12 July 2007
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2993336
25 July 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2726249
13 July 2005
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2607420
26 October 2004
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2226114
12 May 2004
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2065405
24 April 2003
Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1780273
8 April 2003
Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1770209
Deficiency record · 34
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 May 2025
Resolved
Vapor barriers must be provided where insulation of any
type is used in spaces where flammable and combustible
liquids or vapors are present, such as machinery spaces
and paint lockers.
Forward machinery space bulkhead had cables running
through, and temporary fire block ™ in Ziplock ™ bags
that that allowed the passage of vapor.
Vessel has until 5/22/2025 to fix.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2025
Resolved
Remote fuel shutoff stations must be marked in clearly
legible letters at least 25 millimeters (1 inch) high
indicating purpose of the valve and direction of
operation.
Remote fuel shut off at operating station was worn and
did not indicate direction of operation
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 May 2025
Resolved
Watertight hatches must be marked on both sides in
clearly legible letters at least 25 millimeters (1 inch)
high: … “WATERTIGHT HATCH—KEEP CLOSED”
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2025
Resolved
Semi-portable extinguishers must be inspected and
maintained in accordance with NFPA 10: Monthly
inspections required by NFPA 10 may be conducted by the
owner, operator...
Monthly inspections were not being conducted on portable
fire extinguishers
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 May 2025
Resolved
Except on a vessel limited to daytime operations, the
compass must be illuminated…
The magnetic compasses did not illuminate.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 May 2025
Resolved
As an employer, you must provide collectors the name and
telephone number of the appropriate DER to contact about
any problems or issues that may arise during the testing
process.
DER on board was Captain who is enrolled in the
employees drug testing program
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 May 2025
Resolved
A visual indicator must be provided at the operating
station to indicate when any automatic bilge pump is
operating.
Aft bilge light on bridge did not indicate bilge pump
was operating
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2025
Resolved
Each ring life buoy must be marked with Type II
retroreflective material …
The ring buoy on board retroreflective tape was
deteriorated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2025
Resolved
Strong and effective rudder stops must be provided to
prevent jamming and damage to the rudder and its
fittings.
When the operator steered full to starboard, the rudder
stop did not prevent the rudder from hitting the mount
that was holding the hydraulic cylinder in place.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 May 2025
Resolved
Each buoyant apparatus must be fitted with a lifeline,
pendants, a painter, and a light. The painter must: Be
of a dark color if synthetic, or of a type certified to
be resistant to deterioration from ultraviolet light.
The painter attached to the life float is deteriorated
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 May 2025
Resolved
The float-free link required by § 180.130(a)(1) must be:
Of proper strength for the size of the life float or
buoyant apparatus as indicated on its identification
tag.
An identification tag for the float-free link was not
found to indicate proper strength for the size.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Port side fuel shutoff valve is not fully closing and must be fixed.
46 CFR § 182.455(b)(4)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 June 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette. High water level alarm in lazarette is nonoperational and must be fixed.
46 CFR § 182.455(a)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2023
Resolved
Each lifejacket must be marked with Type 1 reflective material. Renew lifejacket reflective tape on affected lifejackets.
46 CFR 185.604(h)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 April 2023
Resolved
Each battery used in an item of lifesaving equipment … must be replaced during the annual inspection if the expiration date of the battery has passed. Replace floating waterlight batter.
46 CFR 185.726(d)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2022
Resolved
Replace retro-reflective tape on all life jackets to meet 46CFR160.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2022
Resolved
Port side fuel return line is worn. Replace with marine grade fuel line.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 March 2022
Resolved
A vessel must undergo a drydock and internal structure examination at least once every two years. Last drydock and internal examination was conducted on 25FEB2020 and vessel is not permitted to operate until a drydock and internal structure inspection has been completed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 April 2008
Resolved
Install retro reflective tape on life ring buoy as required.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 April 2008
Resolved
Replace retro reflective tape on 20 adult and 03 child life jackets as needed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 10 April 2008
Resolved
Provide valid alcohol test kits.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 1 April 2008
Resolved
Provide 02 fully charged A/B II fire extinguishers onboard.
Communications › Radio Communications › EPIRB
Issued 12 July 2007
Resolved
Provide proof of current EPIRB NOAA Registration.
Communications › Radio Communications › EPIRB
Issued 12 July 2007
Resolved
Repair/service EPIRB and ensure satisfactory operation.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 July 2006
Resolved
Stow child size life jackets IAW 46 CFR 180.78
Documentation
Issued 24 April 2003
Resolved
Provide copy of required approved plans. LEGACY COMPONENT DESC: Plans
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 24 April 2003
Resolved
Properly install fuel tank vent to vent overboard.
Accommodation/Occupational Safety › Ventilation
Issued 24 April 2003
Resolved
Provide/install latch for engineroom ventilation closures.
Navigation › Piloting/Steering
Issued 24 April 2003
Resolved
Provide current required charts and publications for operating area.
Documentation › Certificates/Documents › FCC SSL
Issued 24 April 2003
Resolved
Provide FCC Radiotelephony Certificate
Documentation › Logs/Records
Issued 24 April 2003
Resolved
Provide copy of applicable FCC regulations
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 24 April 2003
Resolved
Install railing courses on aft railing where missing to reduce opening to less than 12 inch spacing.
Electrical › Lighting (emergency)
Issued 24 April 2003
Resolved
Install emergency lighting or equivalent for escape from passenger head.
Lifesaving › Lifebuoys
Issued 24 April 2003
Resolved
Install 18 ft lanyard for waterlight for ringbuoy.