Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFORT LAUDERDALE, FL
Endorsements, as the file codes themcw_un, rec
DocumentationValid · issued 9 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
24 February 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8314845
15 May 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8135708
26 June 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7942722
27 February 2024
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7871398
5 April 2023
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7660202
27 April 2022
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7439320
16 March 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7414023
14 March 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7411201
1 July 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7241432
6 October 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7072185
25 February 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6915069
14 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6683601
12 April 2018
COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6388044
2 February 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6348495
20 June 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6181059
6 June 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5898658
21 March 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5837517
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 May 2025
Resolved
Vapor barriers must be provided where insulation of any
type is used in spaces where flammable and combustible
liquids or vapors are present, such as machinery spaces
and paint lockers.
Forward machinery space bulkhead had cables running
through, and temporary fire block ™ in Ziplock ™ bags
that that allowed the passage of vapor.
Vessel has until 5/22/2025 to fix.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 May 2025
Resolved 22 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2025
Resolved
Remote fuel shutoff stations must be marked in clearly
legible letters at least 25 millimeters (1 inch) high
indicating purpose of the valve and direction of
operation.
Remote fuel shut off at operating station was worn and
did not indicate direction of operation
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 22 July 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 May 2025
Resolved
Watertight hatches must be marked on both sides in
clearly legible letters at least 25 millimeters (1 inch)
high: … “WATERTIGHT HATCH—KEEP CLOSED”
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 23 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2025
Resolved
Semi-portable extinguishers must be inspected and
maintained in accordance with NFPA 10: Monthly
inspections required by NFPA 10 may be conducted by the
owner, operator...
Monthly inspections were not being conducted on portable
fire extinguishers
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 15 May 2025
Resolution: Discussed adding inspeciton to thier EPIRB monthly logs
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 May 2025
Resolved
Except on a vessel limited to daytime operations, the
compass must be illuminated…
The magnetic compasses did not illuminate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 22 July 2025
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 May 2025
Resolved
As an employer, you must provide collectors the name and
telephone number of the appropriate DER to contact about
any problems or issues that may arise during the testing
process.
DER on board was Captain who is enrolled in the
employees drug testing program
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 23 July 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 May 2025
Resolved
A visual indicator must be provided at the operating
station to indicate when any automatic bilge pump is
operating.
Aft bilge light on bridge did not indicate bilge pump
was operating
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 22 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2025
Resolved
Each ring life buoy must be marked with Type II
retroreflective material …
The ring buoy on board retroreflective tape was
deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 22 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2025
Resolved
Strong and effective rudder stops must be provided to
prevent jamming and damage to the rudder and its
fittings.
When the operator steered full to starboard, the rudder
stop did not prevent the rudder from hitting the mount
that was holding the hydraulic cylinder in place.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 22 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 May 2025
Resolved
Each buoyant apparatus must be fitted with a lifeline,
pendants, a painter, and a light. The painter must: Be
of a dark color if synthetic, or of a type certified to
be resistant to deterioration from ultraviolet light.
The painter attached to the life float is deteriorated
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 22 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 May 2025
Resolved
The float-free link required by § 180.130(a)(1) must be:
Of proper strength for the size of the life float or
buoyant apparatus as indicated on its identification
tag.
An identification tag for the float-free link was not
found to indicate proper strength for the size.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 22 July 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Port side fuel shutoff valve is not fully closing and must be fixed.
46 CFR § 182.455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 June 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette. High water level alarm in lazarette is nonoperational and must be fixed.
46 CFR § 182.455(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2023
Resolved
Each lifejacket must be marked with Type 1 reflective material. Renew lifejacket reflective tape on affected lifejackets.
46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 10 April 2023
Resolution: New SOLAS retroreflective tape was applied
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 April 2023
Resolved
Each battery used in an item of lifesaving equipment … must be replaced during the annual inspection if the expiration date of the battery has passed. Replace floating waterlight batter.
46 CFR 185.726(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 10 April 2023
Resolution: Both waterlight batteries were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2022
Resolved
Replace retro-reflective tape on all life jackets to meet 46CFR160.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 5 April 2023
Resolution: This deficiency was for all replacing the SOLAS tape on the adult lifejackets, and was verified on subsequent exam on 5Apr2023. The new one issued on 5Apr2023 was mainly for the child sized lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2022
Resolved
Port side fuel return line is worn. Replace with marine grade fuel line.
Action required: 10 - Deficiency Rectified
Resolved 27 April 2022
Resolution: Operator replaced all fuel hoses the same day, inspectors returned to vessel and conducted operational test.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 March 2022
Resolved
A vessel must undergo a drydock and internal structure examination at least once every two years. Last drydock and internal examination was conducted on 25FEB2020 and vessel is not permitted to operate until a drydock and internal structure inspection has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2022
Resolution: Completed satisfactory ISE/drydock examination.