Records from 2003 to 2007. Most recent: inspection, 17 July 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
17 July 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2998178
18 May 2007
MTSA/ISPS Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2947267
20 June 2006
Hull Examination · Internal Structural Exam · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2687759
23 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571566
22 June 2005
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2427795
23 May 2005
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2373199
23 May 2005
Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2378436
4 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303739
10 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290198
1 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232671
9 August 2004
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2204056
24 May 2004
MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066437
24 May 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2076726
29 October 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1938497
16 July 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1848247
16 July 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1848294
23 May 2003
Initial Construction-Excluding Oversight · Initial Certification · Inclining Experiment · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1799551
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 18 May 2007
Resolved
Provide copy of valid fixed/portable fire protection equipment service report.
Due 25 May 2007
Resolved 2 June 2007
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 18 May 2007
Resolved
Provide copy of valid fire detection service/installation report. Provide 10 min rounds of spaces/firewatch. (Due date extended to 29Jun07 due to the lack of available service technicians in MX and time required to obtain visa for US technician)
Due 8 June 2007
Resolved 25 June 2007
Stability › Watertight Integrity › General
Issued 18 May 2007
Resolved
Provide photographs of properly installed watertight door switches and test, include Capt statement of proper function.
Due 8 June 2007
Resolved 2 June 2007
Stability › Watertight Integrity › General
Issued 18 May 2007
Resolved
Provide photo of properly plugged bulkhead penetration between machinery and engine room.
Due 25 May 2007
Resolved 18 May 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 18 May 2007
Resolved
Provide capt statement of repaired #2 RPM sensors, both main and generator.
Due 8 June 2007
Resolved 2 June 2007
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 18 May 2007
Resolved
Provide photo of properly labeled emergency exits on weather deck.
Due 25 May 2007
Resolved 26 May 2007
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 20 June 2006
Resolved
GMDSS SSB/DSC unit not operational.
Condition: Improper/Lack of Maintenance
Due 29 July 2006
Resolved 5 August 2006
Electrical › Electrical Distribution System (emergency) › Junction Box
Issued 20 June 2006
Resolved
Make wiring connection to General Alarm annuciator within junction box on main deck aft superstructure.
Condition: Improper Installation
Due 29 July 2006
Resolved 5 August 2006
Lifesaving › Lifebuoys › Stowage
Issued 23 May 2005
Resolved
Prove proper labeling of all lifesaving equipment as per 46 CFR 131.875
Due 23 June 2005
Resolved 22 June 2005
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 23 May 2005
Resolved
Replace both pressure vessel relief valves with PSI limits at or below MAWP of vessels. Prove proper operation.
Due 23 June 2005
Resolved 22 June 2005
Lifesaving › Line-Throwing Appliances › Lines
Issued 23 May 2005
Resolved
Provide auxiliary line throwing gun line as per 46 CFR 133.170 (c) (ii).
Due 23 June 2005
Resolved 22 June 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 23 May 2005
Resolved
Provide proper CO2 fire servicing report showing true agent weights.
Due 23 June 2005
Resolved 22 June 2005
Lifesaving › Line-Throwing Appliances › Lines
Issued 9 August 2004
Resolved
Provide auxiliary line for line throwing gun as required by 46 CFR 133.170 (c) (2).
Due 9 September 2004
Resolved 8 September 2004
Navigation › Piloting/Steering › Marine Charts
Issued 9 August 2004
Resolved
Prove charts are being corrected with notice to mariners.
Due 9 September 2004
Resolved 8 September 2004
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 August 2004
Resolved
Provide current publications for the vessel as per 46 CFR 130.330
Due 9 September 2004
Resolved 8 September 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 August 2004
Resolved
Provide four self-igniting lights under approval series 160.010 attached to liferings on the vessel.
Due 9 September 2004
Resolved 12 August 2004
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 9 August 2004
Resolved
Repair fuel leak on racor filter in bow thruster room.
Due 9 September 2004
Resolved 8 September 2004
Engineering › Pressure Vessel › Relief Valve
Issued 9 August 2004
Resolved
Provide relief valve 100 degrees F or less or have hot water heater available for internal inspection.
Due 9 September 2004
Resolved 8 September 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 August 2004
Resolved
Properly identify lifebuoys as per 46 CFR 133.70
Due 9 September 2004
Resolved 8 September 2004
Fire Fighting › Fire Hydrants › Condition
Issued 9 August 2004
Resolved
Provide spanner wrench for all fire stations.
Due 19 August 2004
Resolved 12 August 2004
Engineering › Bilge Water Management System › Not Operational
Issued 9 August 2004
Resolved
Prove audible and visual alarm on high bilge alarm as per 46 CFR 130.460
Due 16 August 2004
Resolved 12 August 2004
Construction/Loadline
Issued 23 May 2003
Resolved
Provide approved F/W system plans.
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 16 July 2003
Resolution: Provided.
Construction/Loadline
Issued 23 May 2003
Resolved
Provide approved propulsion control plans.
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 29 October 2003
Resolution: Provided, cover letter serial # E2-0306072.
Construction/Loadline
Issued 23 May 2003
Resolved
Provide approved fire main system plans.
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 29 October 2003
Resolution: Provided, cover letter Serial# E1-0305465.
Construction/Loadline
Issued 23 May 2003
Resolved
Provide approved plans for fire monitor system.
Action required: 705 - Other - as specified
Due 18 July 2003
Resolved 29 October 2003
Resolution: Provided, cover letter Serial# E1-0305262.