EXCALIBUR

EXCALIBUR is a 2002 tank ship. The Coast Guard has recorded 27 inspections since 2003, most recently in November 2021, along with 5 deficiencies and 5 operational controls.

Records from 2003 to 2021. Most recent: inspection, 12 November 2021.

Built
2002
Last inspected
12 November 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9230050 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
612856
Flag
BELGIUM
—
Maury page id
psix-612856

Inspections, by type

…with no type recorded4
Years with a record 11 calendar years (2003–2021)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it93786 - Convention (Subpart B), Gross Ton
107046 - Displacement, Metric Ton
77848 - Dead Weight, Metric Ton
28136 - Convention (Subpart B), Net Ton
93786 - Regulatory (Subpart C or D), Gross Ton
28136 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

12 November 2021 PSC A · COC-GAS Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7343401
16 June 2021 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7241466
13 September 2020 Ballast Water Examination · COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7055013
13 September 2020 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7066671
15 May 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6684720
18 April 2019 Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6660653
28 February 2019 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6632403
5 February 2019 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6619647
4 January 2019 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6605639
8 December 2018 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6594081
24 October 2018 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6567389
16 September 2018 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6539414
19 July 2018 Special
Type not classified · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6484583
23 April 2018 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6390233
23 July 2012 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4387699
5 June 2008 NPV Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3227810
15 May 2008 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3208118
12 May 2008 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3199451
25 July 2007 Ballast Water Examination · Deficiency Check · COC-GAS Renew · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3007177
16 September 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2779605
29 November 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2542835
29 November 2005 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2544018
28 November 2005 PII Safety Exam · Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2542031
26 November 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2540870
28 June 2004 Random ISPS/MTSA/PSC
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2113952
6 June 2004 Certificate of Compliance · MTSA/ISPS Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2090180
4 April 2003 Letter of Compliance (Initial/Renewal)
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1781751

Deficiency record · 5

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2019 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Where electrical equipment is installed in gas-dangerous spaces or zones it should be to the satisfaction of the administration. PSCO observed a grounding strap on electrical conduit trunk for main cargo pump #2 broken. In addition, a fusible link (forward) piping was wasted.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 May 2019
Resolution: Received BV Class report satisfying the deficiency.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 April 2019 Resolved
Fire boundaries between cargo spaces (compressor room) and open deck shall be A-60. PSCO observed compressor room bulkhead was not gas tight, in way of safety relief valve piping.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 May 2019
Resolution: Received BV Class report satisfying the deficiency.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 5 May 2008 Resolved
Ballast water records were found with missing and inaccurate information. Vessel is to conduct training with all responsible officers and provide masters report to local [name withheld] 19MAY2008.
Condition: Improper Installation
Due 19 May 2008
Resolved 15 May 2008
Resolution: 5/15/08 Received masters report stating that training has been conducted with all deck officers. Deficiency issued from activity 3199451 on 5/12/08.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 28 November 2005 Resolved
#1 high duty compressor supply pipe has unauthorized support strapping system. Have class society surveyor attest within 30 days.
Action required: 705 - Other - as specified
Due 29 December 2005
Resolved 16 September 2006
Resolution: Recieved class report attesting vessel remains in class with support strapping system.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 4 April 2003 Resolved
Obtain statement of fact concerning Vapor Control System is in compliance with 46CFR part 39. Prior to next U. S. Port LEGACY COMPONENT DESC: Statement from Classification Society
Action required: 15 - Rectify deficiencies by next port
Resolved 21 June 2004
Resolution: BOSMS received class attestation regarding compliance of system.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.