MAURY USCG vessel records Sign in
← All vessels

PAULINE

PAULINE is a 1975 freight ship. The Coast Guard has recorded 44 inspections since 2003, most recently in February 2024, along with 57 deficiencies and 25 operational controls.

Records from 2003 to 2024. Most recent: inspection, 5 February 2024.

Built
1975
Last inspected
5 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7413919 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO-2868
612910
Flag
PANAMA
—
Maury page id
psix-612910

Inspections, by type

…with no type recorded30
Years with a record 7 calendar years (2003–2024)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1096 - Regulatory (Subpart C or D), Gross Ton
565 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 44

5 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7860890
22 October 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3349506
12 June 2007 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2958995
12 January 2007 Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2860299
8 January 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2852198
7 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2851509
9 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2706603
7 June 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2673287
6 June 2006 ISPS II Exam · MARPOL Annex I Examination · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2671850
15 March 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2603289
10 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2564707
9 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2563625
12 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2533212
17 October 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2515910
9 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2510967
9 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2487982
7 September 2005 ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2486604
6 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2485842
3 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2482548
5 August 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2452571
21 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2316124
25 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2299293
19 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2295908
17 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2276120
8 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2255806
4 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2253354
12 November 2004 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2239844
7 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2236112
18 October 2004 PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2223210
12 October 2004 PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2218722
24 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2204289
10 September 2004 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2192638
10 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2193530
8 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2190470
17 June 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2101808
20 May 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2073959
19 May 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2072148
21 April 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2049509
5 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2038014
30 October 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1939096
19 August 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1880625
11 July 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1844801
18 April 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1776097
25 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1762697

Deficiency record · 57

Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 12 June 2007 Resolved
Cargo Ship Safety Construction Certificate expired 18May07. No valid certificate onboard at time of inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2007
Resolved 5 July 2007
Resolution: Def Corrected
Fire Fighting › Fire Main › Condition
Issued 12 June 2007 Resolved
Fire main has leak in piping. Fire main wasted. Port State Control Officer witnessed under present condition cannot provide pressure to fight a fire.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2007
Resolved 5 July 2007
Resolution: Def Corrected
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 12 June 2007 Resolved
Cargo Ship Safety Certificate #PM-07-01-0 is valid only with form R. Form R on board is #PM-07-01-065. Certificate does not endorse form R. Flag to attest corresponding numbers.
Action required: 705 - Other - as specified
Due 12 July 2007
Resolved 5 July 2007
Resolution: Def Corrected
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 June 2007 Resolved
Found several lifebouys missing vessel name and with wasted lines.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2007
Resolved 5 July 2007
Resolution: Def Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2007 Resolved
Found external refrigerators on deck to have improper electrical wires "extension cords." Cords do not protect against short circuit.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2007
Resolved 5 July 2007
Resolution: Def Corrected
Navigation › Piloting/Steering › Marine Charts
Issued 12 June 2007 Resolved
Navigational charts for inbound/outbound Miami transit not updated since 2006. Latest Notice to Marines not updated on charts.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2007
Resolved 5 July 2007
Resolution: Def Corrected
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 June 2007 Resolved
Vessel did not have required US Coast Pilot publication.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2007
Resolved 5 July 2007
Resolution: Def Corrected
Lifesaving › Rescue Boat › Hull (rigid)
Issued 12 June 2007 Resolved
Vessel's rescue boat has rotted underdeck beam. Structural integrity compromised such that it cannot function as intended with persons inside.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2007
Resolved 5 July 2007
Resolution: Def Corrected
Pollution Prevention/Response › Prevention Equipment › Internal Cargo Transfer Capability
Issued 12 June 2007 Resolved
Vessel has capacity of 15,000 gallons of oil and did not have required oil transfer procedures. Vessel prohibited from conducting bunkering operations in the US.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2007
Resolved 5 July 2007
Resolution: Def Corrected
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 12 January 2007 Resolved
Bildge float is not working properly. Original bildge float is missing. Vessel has a 01 gallon milk jug as a temporary bildge float.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2007
Resolution: Def Corrected
Personnel › Certificates/Documents/Licenses › MMD, Able Seaman
Issued 6 June 2006 Resolved
Provide or letter from Panama attesting to certification of [name withheld] as an A/B.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2006
Resolution: Received fax from Panama.
Accommodation/Occupational Safety › Ventilation › General
Issued 6 June 2006 Resolved
Emergency generator compartment contains excessive smoke and heat due to poor ventilation. Provide ventilation to remove excessive heat and smoke.
Due 6 July 2006
Resolved 12 January 2007
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 25 January 2006 Resolved
33U.S.C.1321(j)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge. 33U.S.C.1321(j)(D)(ii)-The NTVRP does not provide 24-hour contract information for the qualified individual, or indicate that the qualified individual will have immediate contact with the NRC.
Due 25 February 2006
Resolved 15 January 2009
Resolution: NTVRP plan #03505 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 25 January 2006 Resolved
33U.S.C.1321(j)(D)(i)-The NTVRP does not clearly identify the vessel's intended areas of operation/COTP zones. In addition, it does not include the volume and type of oil that would be involved in a worst case discharge. The tank capacities provided are not consistent with each other. 33U.S.C.1321(j)D)(iv)-The NTVRP does not address training as well as all applicable drill/exercise frequencies.
Due 25 February 2006
Resolved 15 January 2009
Resolution: NTVRP plan #03505 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Electrical › Electrical Distribution System (service) › Cable
Issued 7 September 2005 Resolved
Electrical connections for air condition and fans not permanently installed
Action required: 705 - Other - as specified
Resolved 28 September 2005
Resolution: Received class report attesting to repair and inspected satisfactory
Electrical › Electrical Distribution System (service) › Cable
Issued 7 September 2005 Resolved
Connections for light in steering room,
Action required: 705 - Other - as specified
Resolved 28 September 2005
Resolution: Received class report attesting to repair and inspected satisfactory
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 September 2005 Resolved
Have chief engineer complete training on OWS operation. Be able to show proper operation prior to next us port.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 October 2005
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 September 2005 Resolved
Fuel leak at day tank emergency cut off.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2005
Resolution: Leak was corrected, tighten bolts. Received class report attesting to repair and inspected satisfactory.
Engineering › Fuel Oil Service System › Piping
Issued 7 September 2005 Resolved
Fuel leak at day tank level gauge
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2005
Resolution: Refitted gasket, tighten bolts. Received class report attesting to repair and inspected satisfactory.
Personnel › Certificates/Documents/Licenses › License, Assistant Engineer
Issued 7 September 2005 Resolved
2nd enginner does not have a flag state endorsement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2005
Resolution: Recieved 2nd Engineer endorsement.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 7 September 2005 Resolved
Emergency battery storage room does not have proper ventilation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2005
Resolution: Installed proper ventilation. Received class report attesting to repair and inspected satisfactory
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 7 September 2005 Resolved
Emergency batteries are missing fill caps and leaking
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2005
Resolution: Replaced battery and caps. Received class report attesting to repair and inspected satisfactory
Navigation › Piloting/Steering › Marine Charts
Issued 7 September 2005 Resolved
Charts on bridge are not up to date
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2005
Resolution: Received updated charts per NTM 36/2005
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 7 September 2005 Resolved
Vessel missing 33 CFR Part 125 to 199
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2005
Resolution: Purchase CFR.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 7 September 2005 Resolved
Vessel was not incompliance with the current Ballast Water Management policy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2005
Resolution: Showed proper usage and submission Ballast Water Management report.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 18 October 2004 Resolved
charts were found not updated and no correction log was shown.
Action required: 15 - Rectify deficiencies by next port
Resolved 12 November 2004
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 12 October 2004 Resolved
Vessels class documents issued 15JUN03 did not have current audit/endorsement dates. Phoncon with International Registry of Shipping (IRS) Representative indicated they have not attended because the ship mangaement has not responded to the quotes provided to them.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2004
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 12 October 2004 Resolved
Vessels class documents issued 15JUN03 did not have current audit/endorsement dates. Phoncon with International Registry of Shipping (IRS) Representative indicated they have not attended because the ship mangaement has not responded to the quotes provided to them.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2004
Documentation › Certificates/Documents › International Load Line Certificate
Issued 12 October 2004 Resolved
Vessels class documents issued 15JUN03 did not have current audit/endorsement dates. Phoncon with International Registry of Shipping (IRS) Representative indicated they have not attended because the ship mangaement has not responded to the quotes provided to them. - ICLL 66 Article 19 3(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2004
Documentation › Certificates/Documents › IOPP Certificate
Issued 12 October 2004 Resolved
Vessels class documents issued 15JUN03 did not have current audit/endorsement dates. Phoncon with International Registry of Shipping (IRS) Representative indicated they have not attended because the ship mangaement has not responded to the quotes provided to them. - MARPOL Annex 1 Reg 8/2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 21 April 2004 Resolved
Make proper repairs or replace broken (Customs) fuel filters to satisfaction of flag state rep.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2004
Construction/Loadline › Penetrations › Weld
Issued 21 April 2004 Resolved
Boundry between engine and steering gear room is not adequate. Pipes between spaces are not sealed correctly. Repair to the satisfaction of flag state rep.
Due 21 May 2004
Resolved 18 October 2004
Operations/Management › Drills/Instruction
Issued 21 April 2004 Resolved
Complete drills in presence of a USCG Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2004
Electrical › Electric Generation Source (emergency)
Issued 21 April 2004 Resolved
Prove proper operation of Emergency Disel Generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2004
Pollution Prevention/Response › Prevention Equipment
Issued 21 April 2004 Resolved
Flag Rep. to verify proper operation of OWS. Ship is to retain oily waste until flag report is approved by USCG. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Due 21 May 2004
Resolved 30 April 2004
Accommodation/Occupational Safety
Issued 21 April 2004 Resolved
Vessel shall fumigate galley. Galley is infested with roaches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2004
Engineering › Generator (propulsion/auxiliary-electric)
Issued 21 April 2004 Resolved
Properly replace fuel hoses on Emergency Diesel Generator and test to satisfaction of flag state rep.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2004
Lifesaving › Line-Throwing Appliances
Issued 30 October 2003 Resolved
Provide proper number of line throwing devices. Provide faxed receipts to MSO Miami for purchase of line throwing device. 60 SOLAS III/23(a) LEGACY COMPONENT DESC: Lines
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2003
Pollution Prevention/Response › Prevention Equipment
Issued 30 October 2003 Resolved
Have flag state representative attest to proper installation and test of new OWS and update IOPP Certificate for throughput. Prove proper operation in presence of USCG Inspector at next US Port. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 2 December 2003
Electrical › Electrical Distribution System (service)
Issued 30 October 2003 Resolved
Removed dead ended wires in crew's wash closet and crew's laundry. 60 SOLAS II/27(a)(iv)(2) LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 30 November 2003
Resolved 31 October 2003
Lifesaving › Rescue Boat
Issued 30 October 2003 Resolved
Prove proper operation of rescue boat motor. LEGACY COMPONENT DESC: Propulsion Engine
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 October 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 25 March 2003 Resolved
Provide fixed fire fighting system in engine room as per SOLAS 60 II/65.H
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Construction/Loadline › Structures
Issued 25 March 2003 Resolved
Weather tight doors on main deck are out of adjustment. make doors weather tight. LEGACY COMPONENT DESC: Door
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Lifesaving › Inflatable Liferafts
Issued 25 March 2003 Resolved
Hydrostatic releases on both liferafts are expired. Install new releases. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Electrical › Electrical Distribution System (service)
Issued 25 March 2003 Resolved
Repair dead-ended wireing in Battery Room, Laundry room, crew's wash closet, #1 A/B stateroom. Provide covers for lights in Bosun stores and interior passageways. LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Navigation › Collision/Grounding Avoidance
Issued 25 March 2003 Resolved
Repair echo depth sounder. LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Due 15 July 2003
Resolved 19 August 2003
Engineering › Fuel Oil Service System
Issued 25 March 2003 Resolved
Install proper flexible fuel line on boiler.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Electrical › Electric Supply System (service)
Issued 25 March 2003 Resolved
Properly stow Port side starting batteries IAW SOLAS 60 II/27 LEGACY COMPONENT DESC: Battery Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Electrical › Electric Supply System (service)
Issued 25 March 2003 Resolved
Properly install charger for batteries for main engine and ships service generators IAW SOLAS 60 II/27 LEGACY COMPONENT DESC: Battery Charger
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Electrical › Electrical Distribution System (service)
Issued 25 March 2003 Resolved
Remove extension cords throughout machinery spaces. Properly wire freezers. LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Electrical › Electric Generation Source (emergency)
Issued 25 March 2003 Resolved
Properly repair leak in fuel line for emergency generator fuel filter.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Electrical › Electric Generation Source (emergency)
Issued 25 March 2003 Resolved
Demonstrate proper operation of energency gererator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 25 March 2003 Resolved
Repair pilot ladder.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Accommodation/Occupational Safety › Messroom
Issued 25 March 2003 Resolved
Galley and lower living spaces are infested with insects. Fumigate crew galley and staterooms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Operations/Management › Drills/Instruction
Issued 25 March 2003 Resolved
Vessel to complete drills after all items are repaired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Documentation › Certificates/Documents
Issued 25 March 2003 Resolved
Vessel has expired certificate of registration, must obtain new one before continuing cargo operations. LEGACY COMPONENT DESC: Certificate of Registration
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2024
Resolution: Received a valid certificate of registration. Cargo ops are authorized and COTP #1762697-2 has been canceled.
Documentation › Certificates/Documents
Issued 25 March 2003 Resolved
Vessel has expired safety radio certificate. LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2003
Resolution: A valid cargo ship safety radio was provided and equipment tested on board to verify its accuracy.

Ownership record