Records from 2003 to 2025. Most recent: inspection, 16 December 2025.
Inspection history · 55
16 December 2025
COC-CHEM & TVE Renew · PSC B · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8284456
16 November 2024
PSC B · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8035474
5 April 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7890508
28 March 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7886505
15 November 2023
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7822190
14 July 2022
PSC B · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7502302
30 May 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7463144
24 January 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7384629
19 July 2021
Administrative Inspection · COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7254761
14 July 2020
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6999366
17 October 2019
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6836342
1 August 2019
COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6763880
29 July 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6766115
4 May 2019
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6676764
9 August 2018
ISPS II Exam · Ballast Water Examination · COC-CHEM Renew · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6505390
26 September 2017
ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6276881
21 December 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6061111
5 December 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6084121
18 November 2016
Deficiency Check · COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6039712
2 September 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5990733
19 January 2016
ISPS III Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5799412
5 October 2015
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5735961
1 October 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5068816
25 June 2014
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4899091
21 August 2011
ISPS III Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4122208
29 December 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3917249
29 December 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3926899
22 October 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3875639
27 September 2010
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3852314
9 February 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3414911
5 February 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3414610
29 January 2009
Random ISPS/MTSA/PSC · NPV Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3401603
16 November 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3364244
19 September 2008
MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex II Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3322662
24 March 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3170254
21 March 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3168757
28 February 2008
MARPOL Annex II Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3155200
3 December 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3108646
2 October 2007
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3073605
10 September 2007
ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3053978
9 March 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2884721
27 September 2006
ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · COC-CHEM Annual · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2788160
23 May 2006
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2656552
19 May 2006
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2653625
23 January 2006
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2571322
1 September 2005
MARPOL Annex V Examination · ISPS III Exam · STCW 95 Exam · Ballast Water Examination · MARPOL Annex I Examination · ILO-147 Exam · COC-CHEM Renew
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2483189
30 June 2004
ISPS II Exam · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2116407
9 May 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2063083
23 April 2004
MARPOL Annex V Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2050683
9 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1983025
17 November 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1949381
20 August 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1883568
24 April 2003
Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1780030
6 April 2003
Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1768929
5 April 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1768600
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 July 2019
Resolved
EACH SEPERATE CIRCUIT SHALL BE PROTECTED AGAINST SHORT CIRCUIT AND AGAINST OVERLOAD. THE PRIMARY FAN BREAKER WASTED, BURNING WIRES IN THE LOCAL CONTROL PANEL OF THE BOILER.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 July 2019
Resolution: Received, reviewed and accepted class report / proper documentation from class (LR), Master and C/E stating the deficiency was rectified. Faulty electrical breakers installed, tested satisfactory.
12 - Dangerous Goods › N/A - No Subsystem › Temperature control
Issued 9 August 2018
Resolved
01 12105 IBC CODE 7.1.5 50AC MEANS SHALL BE PROVIDED FOR MEASURING THE CARGO TEMPERATURE. PSCO OBSERVED THE 7P CARGO TANK TEMPERATURE SENSOR INOP. VESSEL RESTRICTED FROM LOADING HEATED CARGO IN 7P TANK UNTIL SENSORS ARE REPAIRED.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 August 2018
Resolution: Sensor was repaired. See attached documentation.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 9 August 2018
Resolved
02 06106 IBC CODE 10.2 10C ALL GASKETED CARGO-PIPE JOINTS AND HOSE CONNECTIONS SHALL BE ELECTRONICALLY BONDED. MULTIPLE ELECTRICAL BONDING STRIPS WERE MISSING FROM FLANGES ON STARBOARD MANIFOLD.
Action required: 10 - Deficiency Rectified
Resolved 9 August 2018
Lifesaving › Lifeboat Equipment › Food Ration
Issued 18 November 2016
Resolved
FOOD RATIONS TOTALING NOT LESS THAN 10,000KJ FOR EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCODATE, THESE RATIONS SHALL BE KEPT IN AIRTIGHT PACKAGING AND BE STOWED IN A WATERTIGHT CONTAINER. PSCO DISCOVERED 13 NON AIRTIGHT FOOD RATIONS.74 SOLAS (14)III/13.1.4 LSA CODE 4.4.8.12
Action required: 17 - Rectify deficiencies prior to departure
Due 2 December 2016
Resolved 22 November 2016
Resolution: Received satisfactory documentation showing a purchase order and photos of new lifeboat rations.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 October 2015
Resolved
[40a]74SOLAS(14)/14.2.1.1-Structural fire protection, including fire resisting divisions, and protections of openings and penetrations in these divisions shall be kept in good order. The A-Boundary outside the Em. escape to the E-room was deteriorated. Several A-class door-closers were not working as designed.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 January 2016
Resolution: Deficiency rectified to the satisfaction of attending class surveyor.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 5 October 2015
Resolved
[40a]74SOLAS(04)II-1/45.5.6--Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, fire-resisting properties of the cable. Lighting ballasts were installed without the use of junction boxes and were being held together with electrical tape.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 January 2016
Resolution: Deficiency rectified to the satisfaction of attending class surveyor.
Engineering › Steam System (auxiliary) › Piping
Issued 5 October 2015
Resolved
[40a]74SOLAS(04)II-1/32.4--Every steam generating system which provides services essential for the safety of the ship, or which could be rendered dangerous by the failure of its feedwater supply shall be provided with not less than two separate feedwater systems from and including the feed water pumps. One of the feedwater pumps for the steam system was wasted and unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 January 2016
Resolution: Deficiency rectified to the satisfaction of attending class surveyor.
Construction/Loadline › Hull › Side Shell
Issued 29 December 2010
Resolved
Vessel was involved in an allision. Vessel must submit a class report attesting to the material condition of the vessels hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2010
Resolution: Received class report stating no repairs are required at this time and no conditions of class will be raised.
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 22 October 2010
Resolved
During transfer, the vessel did not notify the barge to slow transfer rate when the high level alarm sounded.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2010
Operations/Management › Pollution › Control of Discharge of NLS Residues
Issued 28 February 2008
Resolved
Person in charge did not follow the vessels procedure and arrangement manual in regard to conducting a prewash of a Cat X Cargo discharged in previous port. Vessel must develop and submit a discharge plan proposal to the satisfaction of CG prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2008
Resolved 29 February 2008
Resolution: Vsl submitted discharge plan for vsl. Plan was reviewed and accepted satisfactory by USCG.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 10 September 2007
Resolved
While conducting a fire drill it was found that 02 SCBA's are leaking oxygen from the seal between the tank and the hose. Vessel must have SCBA's serviced.
Action required: 705 - Other - as specified
Due 17 September 2007
Resolved 2 October 2007
Resolution: This unit attended subject vessel; viewed technician''s report. Cleared 01 deficiency for innoperative SCBA''s.