SAILORS CHOICE

SAILORS CHOICE is a 2003 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 2002, most recently in April 2026, along with 43 deficiencies and 1 casualty investigation in 2011.

Records from 2002 to 2026. Most recent: inspection, 8 April 2026.

Built
2003
Last inspected
8 April 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB3689
613772
Flag
UNITED STATES
366890210
Maury page id
psix-613772

Inspections, by type

…with no type recorded2
Years with a record 22 calendar years (2002–2026)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)55.0 ft × 17.0 ft × 7.3 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYANK BOAT WORKS · TUCKAHOE, NJ, UNITED STATES · built 2003
Hull materialAluminum
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationCase Pending · issued 19 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5223MMSI 366890210 · active · compulsorily equipped · granted 10 April 2024, expires 10 April 2034
WDB3689MMSI 366890210 · expired · compulsorily equipped · granted 19 April 2013, cancelled 15 July 2023
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 32

8 April 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8313980
3 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8097125
31 October 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8025561
8 April 2024 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7891543
27 March 2023 COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7657498
12 October 2022 Internal Structural Exam · Deficiency Check · Drydock Exam · Damage Survey · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7578594
31 May 2022 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7465706
20 October 2021 Examination of Repairs · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7336141
12 May 2021 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7200791
24 April 2020 Annual Inspection · Internal Structural Exam · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6944867
15 November 2019 Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 6856744
8 October 2019 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6831577
23 April 2019 Administrative Inspection · DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6668650
5 April 2018 COI Inspection · Deficiency Check · DAPI Audit · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6385544
19 October 2017 Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294712
16 May 2017 DAPI Audit · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6229260
11 October 2016 Hull Examination · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6034629
5 April 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5839746
8 October 2014 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4977882
19 June 2012 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4380654
7 August 2011 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4137591
11 July 2011 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4077915
20 July 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3540537
27 April 2009 Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3461956
21 April 2008 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3188659
30 April 2007 Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2918957
15 May 2006 Re-Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2649417
27 April 2005 Hull Examination · Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2343522
4 May 2004 Administrative Inspection · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2054640
17 September 2003 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1907656
5 May 2003 In-Service Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1788606
21 May 2002 Simplified Stability Test · Hull Examination · COI Inspection · Plan Review "T" Boat
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1770514

Deficiency record · 43

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 April 2026 Resolved
03 fire extinguisher brackets need to be replaced/ repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 April 2026 Resolved
FCC safety cert. has expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 8 April 2026 Resolved
Monthly EPIRB tests need to be logged.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2025 Resolved
Both PORT and STBD main diesel engines are missing belt guards.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 April 2025 Resolved
Fire buckets need to be labeled correctly with words "FIRE BUCKET".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 3 April 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 May 2022 Resolved
Supervisor missing the proof of training for the EAP. Must provide proof of atleast 1 hr of traing as required.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 20 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 May 2022 Resolved
Life ring throw line did not meet the requirements. Line must be able to float.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 20 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 May 2021 Resolved
Paddles for both life floats were missing. Replace all 4 missing paddles and label them with vessel's name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 28 July 2021
Resolution: Two sets of paddles purchased, labeled and mounted within lifefloats.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 May 2021 Resolved
First aid kit had missing and expired items. Must replace all missing and expired items to meet requlations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 28 July 2021
Resolution: First aid kit was reviewed, expired items removed and replaced with in date items.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 May 2021 Resolved
Alcohol swabs used for testing after a reportable marine casualty were expired. Must replace with enough to test entire crew in an event of a Marine Casualty.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 30 July 2021
Resolution: Purchased new alcohol test swabs with experation date of Aug 31st, 2022. All SAT
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 24 April 2020 Resolved
EPIRB hydrostatic release is expired. Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2020
Resolution: EPIRB hydrostatic release was purchase and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2020 Resolved
Aft bilge pump is inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2020
Resolution: Aft bilge pump was repaired and proper operation was verified.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 24 April 2020 Resolved
Emergency broadcast placard is missing. Post near VHF station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2020
Resolution: Emergency broadcast placard was purchased and placed in proper location.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 April 2020 Resolved
Life floats must have vessel name and passenger capacity marked on both sides.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2020
Resolution: Vessel name and passenger capacity was properly marked on both sides of the life floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2019 Resolved
Port side remote fuel valve is leaking more than 1 drop per second/ Repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2019
Resolution: owner tightened fittings and repaired leak.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 April 2019 Resolved
Stern navigation light is extinguished. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2019
Resolution: light renewed and tested all sat.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 April 2019 Resolved
EPIRB registration is expired. Renew
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2019
Resolution: Owner provided proof of registration renewal.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 April 2019 Resolved
Life float strobe is broken. Renew
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2019
Resolution: New strob was provided and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 April 2019 Resolved
Ring bouy grab line is wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2019
Resolution: New life ring buoy was provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 April 2019 Resolved
VHF must have GPS and MMSI number input. Install.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2019
Resolution: GPS was wired to the radio and tested all sat. MMSI number was input.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 April 2018 Resolved
Tank Room bilge auto switch is inoperable. Repair/renew.
Action required: 10 - Deficiency Rectified
Resolved 5 April 2018
Resolution: Wireing was pulled loose, new connections were installed and tested all sat. Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 April 2018 Resolved
Steering compartment bilge auto float switch is inoperable. Repair/renew.
Action required: 10 - Deficiency Rectified
Resolved 5 April 2018
Resolution: Wireing was pulled loose, new connections were made and switch was tested. All sat. Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2018 Resolved
All PFD need to be cleaned and have new reflective tape installed.
Action required: 10 - Deficiency Rectified
Resolved 19 April 2018
Resolution: NEw SOLAS reflective tape was installed on all PFD that had more than 25% missing or wasted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 October 2017 Resolved
A crack was found in the engineroom at the keel cooler. Keel cooler is integral to the hull, cut out 2 foot section of keel cooler from outside the vessel and renew hull plating and keel cooler piping.
Action required: 10 - Deficiency Rectified
Resolved 1 November 2017
Resolution: Damaged piping was removed, and crack was welded inside and out. new keel cooler pipe was installed, and tested with soap water mixyure and high pressure air. welds are sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 October 2017 Resolved
Crack found in hull approximately 5 feet above waterline near strike damage. grind crack and complete full thickness weld to repair crack.
Action required: 10 - Deficiency Rectified
Resolved 1 November 2017
Resolution: crack was ground from inside and outside. full thickness weld were completed both inside and outside. welsd were tested using soap water mixture and high pressure air. all welds are sat.
Engineering › Sea-water System (primary cooling) › Valve
Issued 8 October 2014 Resolved
Provide new R/W suction valve for the port MDE.
Action required: 705 - Other - as specified
Due 10 October 2014
Resolved 10 October 2014
Resolution: O/O installed new R/W suction valve.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 19 June 2012 Resolved
COD on board is expired, called Vessel Documentation Center and confirmed new COD was mailed to owner. Owner paid for reissue of COD over phone, copy of COD to be e-mailed within 24-48 hours, vessel not allowed to operate until electronic copy is received.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 June 2012
Resolution: Owner received e-mail copy and confirmation of valid COD, original to be mailed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 19 June 2012 Resolved
De-rust and paint portable fire-extinguisher on main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 13 July 2012
Resolution: New fire extinguisher installed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 June 2012 Resolved
Renew retroreflective tape on child size life jackets as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 13 July 2012
Resolution: New retroreflective tape properly installed.
Engineering › Bilge Water Management System › Piping
Issued 21 July 2009 Resolved
All submersible bilge pump discharge piping need positive closing valves installed at the skin of the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 22 July 2009
Resolution: Installed new valves and thu-hull fittings at all bilge pump overboard discharges.
Construction/Loadline › Penetrations › Valve Flange
Issued 21 July 2009 Resolved
All thru-hull pipe penetrations are plastic, must install approved fittings. Schedule 80 plastic may be used instead of metal due to corrosion of aluminum hull. All fittings are more than 2 feet above water line.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 22 July 2009
Resolution: Installed new heavy duty ABYC approved plastic fittings. This will be allowed by local OCMI because of the height above the waterline exceeds 3 feet.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 July 2009 Resolved
Lifebouy missing float light. Install new float light with 3 to 6 feet of line attached and a quick release clip attached to lifebouy.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 22 July 2009
Resolution: New float light installed with 6'' of line and quick disconnect clip. All Sat.
Communications › Radio Communications › EPIRB
Issued 21 July 2009 Resolved
EPIRB hydrostatic release has no date on it. Provide documentary proof of purchase date, or install new hydrostatic release with date clearly marked.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2009
Resolution: New hydrostatic release installed. All Sat.
Engineering › Bilge Water Management System › Pump
Issued 21 July 2009 Resolved
Bilge pump in engine room is on an automatic float switch that is placed only 1 inch from bottom of bilge. Move automatic float switch up to a safe operating level, to avoid automatic discharge of oil into water in non emergency situation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 22 July 2009
Resolution: Master moved the automatic switch up to a level he feels comfortable with for the safety of the vessel. No standard exist for the installation of automatic bilge switch. The master is aware of his responsibility IAW 33 CFR 155.330, and 155.350.
Navigation › Piloting/Steering › US Coast Pilot
Issued 3 May 2007 Resolved
Privide U.S.Coast Pilot, USCG Light List & Tide/Currents table onboard vessel.
Action required: 705 - Other - as specified
Due 3 June 2007
Resolved 16 May 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 May 2007 Resolved
Prove proper operation of steering compartment high level bilge alarm.
Action required: 705 - Other - as specified
Due 3 June 2007
Resolved 16 May 2007
Communications › Radio Communications › EPIRB
Issued 3 May 2007 Resolved
Replace EPIRB antenna.
Action required: 705 - Other - as specified
Due 3 June 2007
Resolved 16 May 2007
Communications › Radio Communications › EPIRB
Issued 3 May 2007 Resolved
Prove proper registration of EPIRB.
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 4 May 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 May 2006 Resolved
Replace expired medicine in first aid kit.
Due 15 June 2006
Resolved 25 May 2006
Communications › Alarms/Indicators › High Water Alarm
Issued 15 May 2006 Resolved
Prove proper operation of visual high level bilge alarm in aft steering space IAW 46 CFR 182.530(a)(1)
Due 15 June 2006
Resolved 25 May 2006
Engineering › Bilge Water Management System › Interface Detector
Issued 27 April 2005 Resolved
Ensure proper operation of visual high water alarm for steering compartment.
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 3 May 2005
Resolution: Observed operational.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 May 2004 Resolved
Renew 1 adult size PFD. Vessel is limited to not more than 51 total persons until completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2004
Resolved 13 May 2004
Resolution: Completed. Received fax copy of invoice indicating new PFD has been purchased.
Accommodation/Occupational Safety › Occupational Safety
Issued 5 May 2003 Resolved
Install netting, mesh or additional courses along railings where passengers have access so that no space is greater than 4 inches. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 17 September 2003
Resolution: Corrected.

Casualty record · 1

7 August 2011Routine · role: Involved in a Marine Casualty · 1 injured · activity 4137591
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.