Records from 2011 to 2026. Most recent: inspection, 8 April 2026.
Inspection history · 18
8 April 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8313980
3 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8097125
31 October 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8025561
8 April 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7891543
27 March 2023
COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7657498
12 October 2022
Internal Structural Exam · Deficiency Check · Drydock Exam · Damage Survey · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7578594
31 May 2022
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7465706
20 October 2021
Examination of Repairs · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7336141
12 May 2021
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7200791
24 April 2020
Annual Inspection · Internal Structural Exam · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6944867
15 November 2019
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 6856744
8 October 2019
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6831577
23 April 2019
Administrative Inspection · DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6668650
5 April 2018
COI Inspection · Deficiency Check · DAPI Audit · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6385544
19 October 2017
Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294712
16 May 2017
DAPI Audit · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6229260
11 October 2016
Hull Examination · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6034629
5 April 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5839746
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 April 2026
Resolved
03 fire extinguisher brackets need to be replaced/ repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 April 2026
Resolved
FCC safety cert. has expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 8 April 2026
Resolved
Monthly EPIRB tests need to be logged.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2025
Resolved
Both PORT and STBD main diesel engines are missing belt guards.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 April 2025
Resolved
Fire buckets need to be labeled correctly with words "FIRE BUCKET".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 3 April 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 May 2022
Resolved
Supervisor missing the proof of training for the EAP. Must provide proof of atleast 1 hr of traing as required.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 20 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 May 2022
Resolved
Life ring throw line did not meet the requirements. Line must be able to float.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2022
Resolved 20 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 May 2021
Resolved
Paddles for both life floats were missing. Replace all 4 missing paddles and label them with vessel's name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2021
Resolved 28 July 2021
Resolution: Two sets of paddles purchased, labeled and mounted within lifefloats.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 May 2021
Resolved
First aid kit had missing and expired items. Must replace all missing and expired items to meet requlations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 28 July 2021
Resolution: First aid kit was reviewed, expired items removed and replaced with in date items.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 May 2021
Resolved
Alcohol swabs used for testing after a reportable marine casualty were expired. Must replace with enough to test entire crew in an event of a Marine Casualty.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 30 July 2021
Resolution: Purchased new alcohol test swabs with experation date of Aug 31st, 2022. All SAT
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 24 April 2020
Resolved
EPIRB hydrostatic release is expired. Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2020
Resolution: EPIRB hydrostatic release was purchase and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2020
Resolved
Aft bilge pump is inoperable. Repair/renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2020
Resolution: Aft bilge pump was repaired and proper operation was verified.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 24 April 2020
Resolved
Emergency broadcast placard is missing. Post near VHF station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2020
Resolution: Emergency broadcast placard was purchased and placed in proper location.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 April 2020
Resolved
Life floats must have vessel name and passenger capacity marked on both sides.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 April 2020
Resolution: Vessel name and passenger capacity was properly marked on both sides of the life floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 April 2019
Resolved
Port side remote fuel valve is leaking more than 1 drop per second/ Repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2019
Resolution: owner tightened fittings and repaired leak.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 April 2019
Resolved
Stern navigation light is extinguished. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2019
Resolution: light renewed and tested all sat.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 April 2019
Resolved
EPIRB registration is expired. Renew
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2019
Resolution: Owner provided proof of registration renewal.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 April 2019
Resolved
Life float strobe is broken. Renew
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2019
Resolution: New strob was provided and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 April 2019
Resolved
Ring bouy grab line is wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2019
Resolution: New life ring buoy was provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 April 2019
Resolved
VHF must have GPS and MMSI number input. Install.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2019
Resolution: GPS was wired to the radio and tested all sat. MMSI number was input.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 April 2018
Resolved
Tank Room bilge auto switch is inoperable. Repair/renew.
Action required: 10 - Deficiency Rectified
Resolved 5 April 2018
Resolution: Wireing was pulled loose, new connections were installed and tested all sat. Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 April 2018
Resolved
Steering compartment bilge auto float switch is inoperable. Repair/renew.
Action required: 10 - Deficiency Rectified
Resolved 5 April 2018
Resolution: Wireing was pulled loose, new connections were made and switch was tested. All sat. Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2018
Resolved
All PFD need to be cleaned and have new reflective tape installed.
Action required: 10 - Deficiency Rectified
Resolved 19 April 2018
Resolution: NEw SOLAS reflective tape was installed on all PFD that had more than 25% missing or wasted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 October 2017
Resolved
A crack was found in the engineroom at the keel cooler. Keel cooler is integral to the hull, cut out 2 foot section of keel cooler from outside the vessel and renew hull plating and keel cooler piping.
Action required: 10 - Deficiency Rectified
Resolved 1 November 2017
Resolution: Damaged piping was removed, and crack was welded inside and out. new keel cooler pipe was installed, and tested with soap water mixyure and high pressure air. welds are sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 October 2017
Resolved
Crack found in hull approximately 5 feet above waterline near strike damage. grind crack and complete full thickness weld to repair crack.
Action required: 10 - Deficiency Rectified
Resolved 1 November 2017
Resolution: crack was ground from inside and outside. full thickness weld were completed both inside and outside. welsd were tested using soap water mixture and high pressure air. all welds are sat.