Records from 2003 to 2025. Most recent: inspection, 9 December 2025.
Inspection history · 74
9 December 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8279999
21 November 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8272340
9 July 2025
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8180073
9 November 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8033434
31 July 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7959722
16 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7809312
28 September 2023
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7795000
16 December 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7610086
2 May 2022
Ballast Water Examination · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7442649
10 September 2021
Internal Structural Exam · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7309277
5 January 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7119938
30 November 2020
Appeal
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7115104
19 October 2020
MTSA Verification · Deficiency Check · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7079757
20 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6956428
25 February 2020
Bulk Liquid Transfer Monitor
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6916220
8 October 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6830411
27 December 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6616854
10 December 2018
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6595075
29 November 2018
Damage Survey · Permit to Proceed
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6589570
2 July 2018
COI Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6476445
4 April 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6384816
13 November 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6305547
7 April 2017
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6119904
4 April 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6118824
8 November 2016
MTSA Verification · Cargo Tank Internal · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6037579
11 April 2016
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5851207
23 November 2015
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5768859
1 May 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5114730
21 November 2014
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5027425
21 November 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5027492
3 September 2014
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4974354
25 September 2013
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4722798
28 August 2013
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4704551
28 June 2013
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4633047
13 September 2012
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4439726
25 January 2012
Periodic Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4231585
26 September 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4162430
29 November 2010
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3900371
21 September 2010
MTSA Verification · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3853984
14 September 2010
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3851860
31 March 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3706340
25 March 2010
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3703213
12 February 2010
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3679052
5 January 2010
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3658804
27 September 2009
In-Service Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3604475
27 September 2009
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3607077
17 August 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3568861
8 June 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3498375
30 March 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3442858
23 January 2009
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3398789
23 January 2009
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3398818
22 January 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3398589
22 January 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3398732
22 January 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3413246
14 January 2009
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3400959
6 October 2008
MTSA Verification · MARPOL Annex I Examination · Administrative Inspection · MARPOL Annex V Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3339352
10 April 2008
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3181410
4 April 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3181127
4 March 2008
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3158203
11 November 2007
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3096511
24 September 2007
Internal Structural Exam · Annual Inspection · Hull Examination · Cargo Tank Internal · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3064699
6 September 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3050584
19 March 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2891871
29 August 2006
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2762716
20 January 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2665021
24 October 2005
MARPOL Annex II Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2520648
23 June 2005
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2400544
4 May 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2349259
8 February 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2289405
11 January 2005
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2272866
14 October 2004
MARPOL Annex I Examination · MTSA Verification · Annual Inspection · MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2220612
26 May 2004
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2116205
11 May 2004
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2064940
5 May 2003
MARPOL Annex II Examination · Initial Certification · Internal Structural Exam · Cargo Tank Internal · MARPOL Annex I Examination · Hull Examination · Construction Oversight · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1786965
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 September 2023
Resolved
Approved portable and semi-portable extinguishers must be installed in accordance with Table 34.50-10(a) of this section. Marine Inspectors found several fire extinguishers with wasted or seized mounting brackets. Replace or repair all wasted or seized mounting brackets including, but not limited to, fire extinguisher station numbers 2, 7, and 10.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2023
Resolved 29 September 2023
Resolution: Brackets replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 28 September 2023
Resolved
A cargo tank of a tank vessel connected to a vapor collection system must be equipped with a permanent or portable cargo gauging device that is a closed type. The closed gauging tank top window for tanks 1S and 4S had missing bolts on the gas tight seal. The hinge covers for tanks 3S and 4P were also missing bolts. Repair all closed gauging equipment to manufacturer's specifications prior to carrying cargoes that require closed gauging, but not later than 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 29 September 2023
Resolution: Gauging repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 September 2023
Resolved
Securing of weathertight doors shall consist of gaskets and clamping devices, or other equivalent means. Numerous weathertight doors were found with inoperable dogs and missing dogging handles. Ensure all watertight doors function as designed and are properly outfitted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 29 September 2023
Resolution: Verified proper door closure.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 28 September 2023
Resolved
The minimum instrumentation, alarms, and safety controls required for specific types of systems are listed in Table 62.35-50. Vessel crew was unable to safely perform required tests for over speed, low lube oil pressure, and high jacket water temperature on all diesel generators. Vessel shall provide proof of required tests by approved third party or provide Class Society approved Periodic Safety Test Procedures to be completed to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 16 October 2023
Resolution: Received class report from ABS satisfying the requirements.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 28 September 2023
Resolved
Unless operating exclusively on voyages between ports within a single Captain of the Port (COTP) Zone, the master, owner, or person in charge of a vessel must submit a ballast water report to the National Ballast Water Clearinghouse (NBIC) by electronic ballast water report format using methods specified at NBIC's Website. Marine Inspectors could not verify that NBIC was receiving the vessel's ballast water reports no later than 6 hours after arrival at port. Although the vessel was maintaining ballast water records on board, the NBIC website reports had no documentation beyond May 2020. Provide evidence of proper submission of NBIC ballast water reports to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 2 October 2023
Resolution: Report was properly submitted to NBIC.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 16 December 2022
Resolved
Each end of each transfer hose on board which is not connected for the transfer of oil or hazardous material must be blanked off with butterfly valves, wafer-type resilient seated valves, blank flanges, or other means acceptable to the COTP or [name withheld] 2 cargo line on starboard manifold was actively leaking gasoline, replace rising stem valve in kind.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2023
Resolved 30 December 2022
Resolution: Verified installation of new valve at the starboard #2 cargo line to be leak free.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 December 2022
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked on the sides of the vessels to the satisfaction of the assigning authority. The marks shall be plainly visible and, if necessary, special arrangements shall be made for this purpose. Starboard Deck Line was not painted in a contrasting color.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2023
Resolved 30 December 2022
Resolution: Verified starboard deck line properly painted.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 September 2021
Resolved
Between sunset and sunrise, the lighting required by 33 CFR 154.570 and 155.790 must be provided during cargo operations.
Several deck lights were not working providing inadequate illumination.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2021
Resolved 23 September 2021
Resolution: Received photo evidence of all deck lights operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 September 2021
Resolved
The frame or support of each required semi-portable fire extinguisher must be welded or otherwise permanently attached to a bulkhead or deck.
The two semi-portable extinguishers were not permanently attached to a bulkhead or deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2021
Resolved 16 September 2021
Resolution: Permanently affixed Semi-portable extinguishers to the deck.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 10 September 2021
Resolved
No person may use any of the equipment within this section for transfer operations unless it is tested and inspected...including emergency shutdown devices.
Inspectors were not able to test the cargo pump shutdowns because of ongoing maintenance.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2021
Resolved 16 September 2021
Resolution: Witnessed satisfactory test of cargo pump shutdown.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 September 2021
Resolved
The valves shall be of substantial construction and first class workmanship and shall be free from imperfections which may affect its serviceability.
The P/V valve on #2p was wasted, leaving the flame screen unsecured.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2021
Resolved 16 September 2021
Resolution: Wasted p/v valve was replaced and the flame screen was properly secured.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 8 October 2019
Resolved
All Machinery associated with cargo loading, unloading, or cooling shall be capable of being shut down from a remote location.
Cargo Pump #1 (Port Side FWD) was not able to be shut down remotely.
Prior to Cargo Operations w/ the #1 Cargo Pump, demonstrate remote operation of shutdowns to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 66 - Prior to drilling or production operations
Resolved 7 November 2019
Resolution: Pump shutdown solenoid had wires detached. Conducted optest. All Sat.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 8 October 2019
Resolved
A space that has a direct opening to any space listed in paragraph (e) through (l) must have only the electric installations that are allowed for that space to which it opens.
The generator space above the #5S cargo tank opens directly into the hazardous zone. Provide temporary proposal within 24hrs. Provide permanent proposal within 30 days. Reference MSC letter Serial# E2-1103376.
Action required: 705 - Other - as specified
Resolved 20 October 2020
Resolution: Ullage opening creating the hazardous zone near the generator room was welded shut.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 October 2019
Resolved
Sidelights each showing an unbroken light over an arc of the horizon of 112.5 degrees and so fixed as to show the light from right ahead to 22.5 degrees abaft the beam on its respective side.
The Port running light was not fully operational and was not visible from directly ahead. 50% of the the LED bulbs were not working.
Action required: 10 - Deficiency Rectified
Resolved 8 October 2019
Resolution: Replaced Port running light.
Construction/Loadline › Markings › Load Line Mark
Issued 23 November 2015
Resolved
The load line marked on the vessel shall be the same as the one depicted on the Load Line Certificate. The ICLL Certificate is issued by DNV and states the letters NV shall be marked on the plimsol mark. The letters AB are currently marked.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 December 2015
Resolved 24 November 2015
Resolution: Class has allowed a stenciled update to the loadline to match the certificate. Permanent letters will be installed at next drydock.
Construction/Loadline › Hull › Hull Plating
Issued 21 November 2014
Resolved
Barge bottomed out at the Port of Albany Scrap Yard on two occasions. Barge is restricted from Cargo Operations and leaving the Port of NY until barge has been gas freed in double spaces and inspected by an MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2014
Resolution: Marine inspectors attended the vessel and found no interior damage within the 3 port ballast tank. 3 port ballast tank encompasses the span of exterior paint scrapes and metal gouging. Damage to bilge keel is external and non-structural in nature.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 3 September 2014
Resolved
120 Volt lighting panel is outfitted with ground detection that is rated for 208 Volt-600 Volt. Submit plans for new ground detection installation to MSC or local OCMI.
Due 15 October 2014
Resolved 22 September 2014
Resolution: Received one line diagram for 120 Volt panel, installation repairs were made and test satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 26 September 2013
Resolved
Cargo Pump Engine #1, #2, and #3 fuel pressure lines are chaffed and damage exposing the 1st layer of protection (wire).
Due 10 October 2013
Resolved 30 October 2013
Resolution: Chaffed fuel pressure lines on cargo pump engines #1, #2, and #3 were replaced with new CG approved hoses.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 26 September 2013
Resolved
#1 Cargo Pump Engine was locked out and tagged out due to faulty mechanical seal on cargo pump. Repair cargo pump and demonstrate shutdown operations of #1 cargo pump engine. Prior to using the #1 cargo pump for cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2013
Resolution: Witness the proper operation of the #1 Cargo Pump and exercised the emergency shutdown.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 26 September 2013
Resolved
Repair cracked visual gauging sight glass on #2p, #3p and #3s cargo tanks.
Due 26 October 2013
Resolved 30 October 2013
Resolution: Installed new visual gauging sight glass on #2p, #3p and #3s cargo tanks.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure Gauge
Issued 26 September 2013
Resolved
Fire extinguisher #12 located in front of #1 and #2 Cargo Pump House pressure gauge is in the RED and not fully charged.
Due 10 October 2013
Resolved 30 October 2013
Resolution: Fire extinguisher #12 was replace with new fully charged fire extinguisher
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 26 September 2013
Resolved
Load Line marking on the HULL does not reflect the ILL Certificate issued by DNV.
Due 26 October 2013
Resolved 30 October 2013
Resolution: Hull Load Line marking reflects the ILL certificate onboard issued by DNV.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 26 September 2013
Resolved
Tank level monitoring device (electronic) gauging system is inoperable on #5p cargo tank.
Due 26 October 2013
Resolved 30 October 2013
Resolution: Digital tank level monitoring device (electronic) gauging system on #5p cargo tank is operating properly.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 September 2010
Resolved
Provide the Cargo Authority Attachment on board the vessel.
**Vessel Operator provided proof that VCS was approved and cargo authority was issued; however there is currently no Cargo Authority Attachment uploaded from MSC. Extended until November 30, 2010 until CAA is uploaded and attached to the COI.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 29 November 2010
Resolution: A new Cargo Attachment Authority #C1-0300441 was uploaded by MSC and issued to the barge. COI was amended to reference the new CAA as an attachment to the COI.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 21 September 2010
Resolved
Provide the Vapor Collection System approval letter on board the vessel.
**Vessel Operator provided proof that VCS installation was approved on a sister barge, however, no VCS approval letter was issued to this barge. Vessel Operator will contact MSC for issuance approval of the VCS.
Action required: 705 - Other - as specified
Due 30 November 2010
Resolved 29 November 2010
Resolution: Deficiency cleared on the basis of Plan Review Extension letter from MSC.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 September 2010
Resolved
Properly paint in black matt paint the starboard navigation light background no later than September 30, 2010.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 24 September 2010
Resolution: Barge crew replaced old box with new one and painted in mat black.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 September 2010
Resolved
Provide proof that navigational lights are approved for type and service no later than September 30, 2010. Current lights did not appear to be satisfactory and inspector was unable to find UL approval number.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 24 September 2010
Resolution: Vessel operator provided manual technical manual from McDermott Light and Signal providing evidence that TB3 running lights met UL 1104 and had a range of 3 miles.
Engineering › Compressed Air System (start air) › Valve
Issued 21 September 2010
Resolved
Make repairs to the air start system for the #1 ship service generator and test under load in the presence of a Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 24 September 2010
Resolution: Generator was repaired and tested under load.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 27 September 2009
Resolved
Brass plug on jumper fitting on #3 cargo pump burst causing discharge of approx 3 gallons of gear oil on deck from the angle drive casing. Properly repair or replace #3 cargo transfer pump and demonstrate satisfactory operation to attending CG Inspector prior to cargo operations with that pump.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 October 2009
Resolution: Brass plug on jumper fitting was re-brazed. Witnessed proper operation of #3 cargo pump and cleared vessel to resume use of the pump for transfer operations.