CEFALU

CEFALU is a 1996 tank ship. The Coast Guard has recorded 20 inspections since 2003, most recently in September 2007, along with 18 deficiencies.

Records from 2003 to 2007. Most recent: inspection, 2 September 2007.

Built
1996
Last inspected
2 September 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9140633 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
613960
Flag
HONG KONG
—
Maury page id
psix-613960

Inspections, by type

…with no type recorded7
Years with a record 5 calendar years (2003–2007)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2998 - Dead Weight, Ton
1222 - Convention (Subpart B), Net Ton
4071 - Simplified, Gross Ton
4071 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 20

2 September 2007 Ballast Water Examination · ISPS III Exam · COC-GAS Annual
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3045245
2 September 2007 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3050325
17 July 2007 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2998704
17 July 2007 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2999876
14 May 2007 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2935919
8 May 2007 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2935914
3 May 2007 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2921769
25 October 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2807546
29 August 2006 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2762669
10 August 2006 COC-GAS Renew · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2743406
9 August 2006 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2771329
21 May 2005 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2363699
21 May 2005 COC-TVE Renew · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2365431
2 October 2004 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2219643
25 August 2004 Ballast Water Examination · ISPS II Exam
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2175809
11 March 2004 Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2022320
21 November 2003 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2050616
28 April 2003 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1781720
21 April 2003 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1775185
12 April 2003 Letter of Compliance (Initial/Renewal)
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1771256

Deficiency record · 18

Documentation › Logs/Records › Oil Record Book
Issued 3 May 2007 Resolved
Update Oil Record Book in accordance with new MARPOL Annex I.
Action required: 705 - Other - as specified
Resolved 8 May 2007
Lifesaving › Lifeboat › Markings
Issued 3 May 2007 Resolved
No retroflective tape on bottom of lifeboat.
Action required: 705 - Other - as specified
Resolved 8 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2007 Resolved
Exposed electrical connections on temperature gauges on deck.
Action required: 705 - Other - as specified
Resolved 14 May 2007
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 10 August 2006 Resolved
Secondary Fire-Fighting Pump not sufficient to meet minimum pressure requirements.
Action required: 705 - Other - as specified
Resolved 29 August 2006
Resolution: The broken crank shaft of the emergency fire pump engine was replaced with new spare. The emergency fire pump was tested satisfactorily.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 10 August 2006 Resolved
Inadequate flame screens in fuel tank vents.
Action required: 705 - Other - as specified
Resolved 29 August 2006
Resolution: According to Class Survey Report, air vents were fixed with flame screens.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 10 August 2006 Resolved
Class A fire doors do not close properly.
Action required: 705 - Other - as specified
Resolved 29 August 2006
Resolution: According to Class Survey Report, all fire doors were able to close properly.
Construction/Loadline › Structures › Door
Issued 10 August 2006 Resolved
Restricted access doors not marked/stenciled legibly.
Action required: 705 - Other - as specified
Resolved 29 August 2006
Resolution: According to Class Survey Report, marking of access doors to restricted areas were completed.
Communications › Internal Communications System › Sound-powered Telephone
Issued 10 August 2006 Resolved
Primary communications from aft steering to bridge inoperative.
Action required: 705 - Other - as specified
Resolved 29 August 2006
Resolution: According to Class Survey Report, the communications between the bridge and the steering gear room was tested satisfactorily.
Construction/Loadline › Structures › Deck Plating
Issued 10 August 2006 Resolved
Catwalk gratings are unsecured.
Action required: 705 - Other - as specified
Resolved 29 August 2006
Resolution: According to Class Survey Report, all gratings were found to be secured properly.
Lifesaving › Launching Appliances › Davit
Issued 23 May 2005 Resolved
Unsatisfactory performance of low and high speeds on starboard lifeboat davit system.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 10 August 2006
Resolution: Cleared Deficiency.
Lifesaving › Lifeboat › Propulsion Engine
Issued 21 May 2005 Resolved
Lifeboat #1 / starboard side. Engine would not start. Second Officer radioed Chief Engineer to try to start engine and he trouble shot for the next hour. Problem was found to be a dead battery. Replace prior to departure from port.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2005
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 May 2005 Resolved
Tidal current table was not onboard.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 10 August 2006
Resolution: Cleared Deficiency.
Lifesaving › Lifejacket/PFD (General)
Issued 12 April 2003 Resolved
Provide the correct PFD instructions for PFD actually onboard the vessel. Place in SOLAS Lifesaving Manual and post for crew awareness. LEGACY COMPONENT DESC: Instructions
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 22 April 2003
Resolution: VESSEL PROVIDED CORRECT PFD INSTRUCTIONS FOR PFD ON BOARD AND PLACED IN SOLAS LIFESAVING MANUAL/POSTED FOR CREW AWARENESS.
Navigation › Collision/Grounding Avoidance
Issued 12 April 2003 Resolved
Make permanent repairs to ship's whistle. LEGACY COMPONENT DESC: Whistle
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 22 April 2003
Resolution: SHIP''S WHISTLE WAS TESTED AND FOUND TO BE SATISFACTORY.
Accommodation/Occupational Safety › Occupational Safety
Issued 12 April 2003 Resolved
Make permanent repairs to Fixed Gas Detection System. LEGACY COMPONENT DESC: Fixed Gas detection System
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 22 April 2003
Resolution: PERMANENT REPAIRS TO FIXED GAS DETECTION SYSTEM WAS FOUND TO BE SATISFACTORY.
Lifesaving › Lifeboat
Issued 12 April 2003 Resolved
Make permanent repairs to #2 Lifeboat Sprinkler System piping at the bow to ensure it remains intact. LEGACY COMPONENT DESC: Fire Protection (water spray system)
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 22 April 2003
Resolution: SATISFACTORY REPAIRS MADE TO #2 LIFEBOAT SPRINKLER SYSTEM PIPING AT BOW.
Lifesaving › Lifeboat
Issued 12 April 2003 Resolved
Unclog sprinkler nozzle tips on #1 Lifeboat Sprinkler System. LEGACY COMPONENT DESC: Fire Protection (water spray system)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 22 April 2003
Resolution: SPRINKLER NOZZLE TIPS WERE UNCLOGGED UPON VISUAL INSPECTION.
Lifesaving › Launching Appliances
Issued 12 April 2003 Resolved
Make permanent repairs to #1 lifeboat releasing gear. Boat failed to release during drill. LEGACY COMPONENT DESC: Release Mechanism
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 22 April 2003
Resolution: SATISFACTORY REPAIRS MADE TO #1 LIFEBOART RELAEASING GEAR.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.