Records from 2003 to 2026. Most recent: inspection, 8 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
8 April 2026
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8324635
15 September 2025
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8235032
5 May 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8128545
11 April 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7893717
28 March 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7857207
6 April 2023
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7661562
2 February 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7631103
26 April 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7438510
23 March 2022
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7417330
4 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7188511
13 October 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7076217
27 July 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7017655
21 May 2019
DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6689375
11 October 2018
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6558690
24 April 2018
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6398050
24 April 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6220590
21 February 2017
Type not recorded
No type recorded · USCGC ALBACORE (WPB 87309) · USCG Northeast District (CGD-NE) · Activity 6282066
17 October 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6023650
11 May 2016
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5874207
22 December 2010
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3937158
28 March 2010
Type not recorded
No type recorded · USCGC TYBEE (WPB 1330) · USCG Northeast District (CGD-NE) · Activity 3704252
16 April 2009
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3457996
27 January 2009
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3401103
6 May 2008
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3199425
8 May 2007
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2925403
27 April 2007
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2917154
4 May 2006
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2647416
22 April 2005
Deficiency Check · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2339571
19 April 2005
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2360391
5 April 2004
MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2036117
5 May 2003
COI Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1786751
30 April 2003
Simplified Stability Test
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1783767
30 April 2003
Plan Review "T" Boat · Construction Oversight
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1783777
24 April 2003
Internal Structural Exam · Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1783779
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 May 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Satisfactory Servicing Report is not available. Additionally, hydrostatic testing of cylinder is required due to extent of corrosion.
46 CFR 176.810 (b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Operator submitted servicing report
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 5 May 2025
Resolved
An interconnected detection and alarm system must: Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR 159.010, as meeting UL 217. Vessel's interconnected detection and alarm system is not certified to UL 217 standard. Owner must submit proposal within 30 days.
46 CFR 181.450 (a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2025
Resolved 7 August 2025
Resolution: Recieved Pictures and video of corrected installtion of Interconnected Detection System onboard.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 April 2024
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight.
&
46 CFR 177.405 (c)- Separation of machinery and fuel tank spaces from accommodation spaces. Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors.
Several bulkhead penetrations are not watertight and can not prevent the passage of vapors.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 12 April 2024
Resolution: 15Nov2024: Emailed [name withheld] acknowledging receipt of 12 April, 2024 email with photo evedence of 04 deficiencies, attached a cg_835 clearing/closing 04 items.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 April 2024
Resolved
Starting motors, generators, and any spark producing device (wires) must be mounted as high above the bilges as practicable. MI observed many Wires laying in the bilges.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 15 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 April 2024
Resolved
A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling water system. Generator raw water cooling strainer is leaking water into the engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 12 April 2024
Resolution: 15Nov2024: Emailed [name withheld] acknowledging receipt of 12 April, 2024 email with photo evedence of 04 deficiencies, attached a cg_835 clearing/closing 04 items.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 April 2024
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Steering compartment light fixture is missing bulb and guard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 15 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 April 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The port Engine Alternator is not connected to a power source.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 12 April 2024
Resolution: 15Nov2024: Emailed [name withheld] acknowledging receipt of 12 April, 2024 email with photo evedence of 04 deficiencies, attached a cg_835 clearing/closing 04 items.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 April 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. CG MI observed several open ended wires.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 12 April 2024
Resolution: 15Nov2024: Emailed [name withheld] acknowledging receipt of 12 April, 2024 email with photo evedence of 04 deficiencies, attached a cg_835 clearing/closing 04 items.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 July 2020
Resolved
A hatch exposed to the weather must be watertight. Fore peak and port side midship hatches, gaskets were rotted. Replace gaskets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 3 August 2020
Resolution: Recieved picture of hatch with new gasket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2020
Resolved
At least one life ring must be fitted with a 60ft lifeline. Vessel had incorrect length of life line. Provide 60ft lifeline.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 3 August 2020
Resolution: Recieved email with new 60ft life line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2020
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with vessels name. Ring life buoy on port side was not labeled. Label vessels name of life ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 3 August 2020
Resolution: Recieved picture with proper label of ring buoy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 July 2020
Resolved
Electrical equipment on a vessel must be installed to protect passengers, crew, and other persons from an electrical hazard. light cover and protective cages were missing on 02 light bulbs in #2 void space. Replace cover and cage
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 3 August 2020
Resolution: protective covers replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2019
Resolved
Post emergency instructions at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pic submitted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2019
Resolved
Clean all engineroom battery connections. Replace all bolts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pic submitted.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 May 2019
Resolved
Replace both engineroom generator exhaust hoses and clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pics
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 May 2019
Resolved
Replace broken EPIRB case.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pics
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 May 2019
Resolved
Replace gasket on collision bulkhead scuttle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pics
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 May 2019
Resolved
Clean and lubricate all scuttle gaskets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pics
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 24 April 2018
Resolved
Vessel only 13 child size PFDs. Vessel is required to carry 14 child size PFDs.
Action required: 705 - Other - as specified
Resolved 24 April 2018
Resolution: Vessel provided 01 child size PFD.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 24 April 2018
Resolved
Vessel on an oceans route must have PFD lights approved IAW 46CFR161.012. Reduced passenger count by 01 until additional light is acquired for oceans/coastwise voyages.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 24 April 2018
Resolution: Lights provided for PFDs same day.
Lifesaving › Hand Flares › Expired
Issued 24 April 2018
Resolved
Vessel had 04 expired flares. Vessel was able to replace flares.
Action required: 10 - Deficiency Rectified
Resolved 24 April 2018
Resolution: vessel provided 04 flares.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 April 2018
Resolved
Vessel must carry first aid kit IAW 46CFR160.041. Vessel is to provide eyewash.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 24 April 2018
Resolution: Eye wash provided for first aid kit same day.
Communications › Radio Communications › EPIRB
Issued 11 May 2016
Resolved
Provide EPIRB IAW 46CFR180.64. Vessel is restricted to <3 miles from shore until rectified.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 25 May 2016
Resolution: Operator installed proper EPIRB with proper registration and current battery.
Stability › Watertight Integrity › General
Issued 11 May 2016
Resolved
Make bulkhead between f/o tanks & lazarette
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 6 July 2016
Resolution: Received email containing pictures indicating hole in bulkhead repaired with marine sealant.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 11 May 2016
Resolved
Clean f/o from under both generators
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2016
Resolved 12 May 2016
Resolution: F/o cleaned under both generators.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 11 May 2016
Resolved
Provide inspection log & conduct inspections as required by 46CFR185.720 & 722
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 6 July 2016
Resolution: Vessel provided log book indicating inspections had been completed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 May 2016
Resolved
Post COI in passenger area
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 12 May 2016
Resolution: COI posted in passenger area.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2016
Resolved
Provide first aid kit IAW 46CFR 184.710 meets 160.041
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 6 July 2016
Resolution: Vessel provided first aid kit that meets 160.041
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 11 May 2016
Resolved
Install blanks in breaker panel on bridge.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 6 July 2016
Resolution: Vessel installed blanks in breaker panel.
Communications › Alarms/Indicators › High Water Alarm
Issued 27 April 2007
Resolved
Ensure proper operation of visual high water alarm for tank room.
Due 10 May 2007
Resolved 6 May 2007
Resolution: Fixed visual high water alarm for tank room.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 27 April 2007
Resolved
Tighten shaft packing on port and stbd main, to secure from excess leakage.
Due 10 May 2007
Resolved 6 May 2007
Resolution: tightened shaft packing on port and stbd. MDE, to secure from excess leakage.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 27 April 2007
Resolved
Provide one adult lifejacket prior to sail.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2007
Resolution: Provided one new adult lifejacket to replace missing jacket.
Lifesaving › Lifefloat › Paddle
Issued 27 April 2007
Resolved
Replace all broken paddles on lifefloats.
Due 10 May 2007
Resolved 6 May 2007
Resolution: Replaced all broken paddles on lifefloats.
Lifesaving › Lifefloat › Markings
Issued 27 April 2007
Resolved
Properly label all paddles and lifefloats with vessel name and lifefloat capacity.
Due 10 May 2007
Resolved 6 May 2007
Resolution: Properly labeled all paddles and lifefloats with vessel name and lifefloat capacity.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 May 2006
Resolved
Prove all crew members for Sea Otter IV and V are enrolled in APCA drug consortium under Sea Otter Inc.
Due 19 May 2006
Resolved 24 May 2006
Lifesaving › Lifefloat › Painter
Issued 4 May 2006
Resolved
Arrrange all life floats to connect individually to painter. Line shall be dark, synthetic and floatable. Disconnect all lines connecting LF's to other LF's.
Due 19 May 2006
Resolved 24 May 2006
Navigation › Piloting/Steering › Magnetic Compass
Issued 22 April 2005
Resolved
Prove proper operation of compass light.
Due 6 May 2005
Resolved 22 April 2005
Resolution: Per faxed ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifefloat › Markings
Issued 22 April 2005
Resolved
Stencil passenger capacity on lifefloats.
Due 6 May 2005
Resolved 22 April 2005
Resolution: Per faxed ltr fm O/O, ltr scanned into documents for this activity.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 22 April 2005
Resolved
Install capture chain on collision compartment hatch cover.
Due 6 May 2005
Resolved 22 April 2005
Resolution: Per faxed ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Buoyant Apparatus
Issued 5 April 2004
Resolved
Provide one waterlight for life float, vessel is restricted to 85 passengers until complete. LEGACY COMPONENT DESC: Waterlight
Due 7 April 2004
Resolved 7 April 2004
Resolution: Owner attested to purchase of waterlight.
Stability
Issued 5 May 2003
Resolved
PRIOR TO CARRYING PASSENGERS, VESSEL MUST HAVE A COPY OF AN APPROVED STABILITY TEST.
Condition: Unknown
Due 9 May 2003
Resolved 12 May 2003
Resolution: OBTAINED AN APPROVED STABILITY TEST LETTER AND FAXED IT TO VESSELS OWNER.