MAURY USCG vessel records
← All vessels

ISLAND CURRENT III

ISLAND CURRENT III is a 2003 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in April 2026, along with 29 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 8 April 2026.

Built
2003
Last inspected
8 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDK8229
614023
Flag
UNITED STATES
Maury page id
psix-614023

Inspections, by type

…with no type recorded1
Years with a record 11 calendar years (2016–2026)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)64.0 ft × 20.0 ft × 10.0 ft
Registered tonnagegross 85 / net 68
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPERFORMANCE MARINE INC · ARUNDEL, ME, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCITY ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it85 - Simplified, Gross Ton
68 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 19

8 April 2026 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8324635
15 September 2025 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8235032
5 May 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8128545
11 April 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7893717
28 March 2024 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7857207
6 April 2023 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7661562
2 February 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7631103
26 April 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7438510
23 March 2022 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7417330
4 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7188511
13 October 2020 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7076217
27 July 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7017655
21 May 2019 DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6689375
11 October 2018 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6558690
24 April 2018 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6398050
24 April 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6220590
21 February 2017 Type not recorded
No type recorded · USCGC ALBACORE (WPB 87309) · USCG Northeast District (CGD-NE) · Activity 6282066
17 October 2016 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6023650
11 May 2016 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5874207

Deficiency record · 29

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 May 2025 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Satisfactory Servicing Report is not available. Additionally, hydrostatic testing of cylinder is required due to extent of corrosion. 46 CFR 176.810 (b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Operator submitted servicing report
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 5 May 2025 Resolved
An interconnected detection and alarm system must: Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR 159.010, as meeting UL 217. Vessel's interconnected detection and alarm system is not certified to UL 217 standard. Owner must submit proposal within 30 days. 46 CFR 181.450 (a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2025
Resolved 7 August 2025
Resolution: Recieved Pictures and video of corrected installtion of Interconnected Detection System onboard.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 April 2024 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. & 46 CFR 177.405 (c)- Separation of machinery and fuel tank spaces from accommodation spaces. Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Several bulkhead penetrations are not watertight and can not prevent the passage of vapors.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 12 April 2024
Resolution: 15Nov2024: Emailed [name withheld] acknowledging receipt of 12 April, 2024 email with photo evedence of 04 deficiencies, attached a cg_835 clearing/closing 04 items.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 April 2024 Resolved
Starting motors, generators, and any spark producing device (wires) must be mounted as high above the bilges as practicable. MI observed many Wires laying in the bilges.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 15 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 April 2024 Resolved
A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling water system. Generator raw water cooling strainer is leaking water into the engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 12 April 2024
Resolution: 15Nov2024: Emailed [name withheld] acknowledging receipt of 12 April, 2024 email with photo evedence of 04 deficiencies, attached a cg_835 clearing/closing 04 items.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 April 2024 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Steering compartment light fixture is missing bulb and guard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 15 November 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 April 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The port Engine Alternator is not connected to a power source.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 12 April 2024
Resolution: 15Nov2024: Emailed [name withheld] acknowledging receipt of 12 April, 2024 email with photo evedence of 04 deficiencies, attached a cg_835 clearing/closing 04 items.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 11 April 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. CG MI observed several open ended wires.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 12 April 2024
Resolution: 15Nov2024: Emailed [name withheld] acknowledging receipt of 12 April, 2024 email with photo evedence of 04 deficiencies, attached a cg_835 clearing/closing 04 items.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 July 2020 Resolved
A hatch exposed to the weather must be watertight. Fore peak and port side midship hatches, gaskets were rotted. Replace gaskets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 3 August 2020
Resolution: Recieved picture of hatch with new gasket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2020 Resolved
At least one life ring must be fitted with a 60ft lifeline. Vessel had incorrect length of life line. Provide 60ft lifeline.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 3 August 2020
Resolution: Recieved email with new 60ft life line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2020 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with vessels name. Ring life buoy on port side was not labeled. Label vessels name of life ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 3 August 2020
Resolution: Recieved picture with proper label of ring buoy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 July 2020 Resolved
Electrical equipment on a vessel must be installed to protect passengers, crew, and other persons from an electrical hazard. light cover and protective cages were missing on 02 light bulbs in #2 void space. Replace cover and cage
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2020
Resolved 3 August 2020
Resolution: protective covers replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2019 Resolved
Post emergency instructions at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pic submitted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2019 Resolved
Clean all engineroom battery connections. Replace all bolts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pic submitted.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 May 2019 Resolved
Replace both engineroom generator exhaust hoses and clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pics
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 May 2019 Resolved
Replace broken EPIRB case.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pics
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 May 2019 Resolved
Replace gasket on collision bulkhead scuttle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pics
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 May 2019 Resolved
Clean and lubricate all scuttle gaskets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: pics
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 24 April 2018 Resolved
Vessel only 13 child size PFDs. Vessel is required to carry 14 child size PFDs.
Action required: 705 - Other - as specified
Resolved 24 April 2018
Resolution: Vessel provided 01 child size PFD.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 24 April 2018 Resolved
Vessel on an oceans route must have PFD lights approved IAW 46CFR161.012. Reduced passenger count by 01 until additional light is acquired for oceans/coastwise voyages.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 24 April 2018
Resolution: Lights provided for PFDs same day.
Lifesaving › Hand Flares › Expired
Issued 24 April 2018 Resolved
Vessel had 04 expired flares. Vessel was able to replace flares.
Action required: 10 - Deficiency Rectified
Resolved 24 April 2018
Resolution: vessel provided 04 flares.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 April 2018 Resolved
Vessel must carry first aid kit IAW 46CFR160.041. Vessel is to provide eyewash.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 24 April 2018
Resolution: Eye wash provided for first aid kit same day.
Communications › Radio Communications › EPIRB
Issued 11 May 2016 Resolved
Provide EPIRB IAW 46CFR180.64. Vessel is restricted to <3 miles from shore until rectified.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 25 May 2016
Resolution: Operator installed proper EPIRB with proper registration and current battery.
Stability › Watertight Integrity › General
Issued 11 May 2016 Resolved
Make bulkhead between f/o tanks & lazarette
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 6 July 2016
Resolution: Received email containing pictures indicating hole in bulkhead repaired with marine sealant.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 11 May 2016 Resolved
Clean f/o from under both generators
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2016
Resolved 12 May 2016
Resolution: F/o cleaned under both generators.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 11 May 2016 Resolved
Provide inspection log & conduct inspections as required by 46CFR185.720 & 722
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 6 July 2016
Resolution: Vessel provided log book indicating inspections had been completed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 May 2016 Resolved
Post COI in passenger area
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 12 May 2016
Resolution: COI posted in passenger area.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2016 Resolved
Provide first aid kit IAW 46CFR 184.710 meets 160.041
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 6 July 2016
Resolution: Vessel provided first aid kit that meets 160.041
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 11 May 2016 Resolved
Install blanks in breaker panel on bridge.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 6 July 2016
Resolution: Vessel installed blanks in breaker panel.

Ownership record