MAURY USCG vessel records
← All vessels

NAVIGATOR SATURN

NAVIGATOR SATURN is a 2000 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in May 2025, along with 6 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 17 May 2025.

Built
2000
Last inspected
17 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 May 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9177569
614227
Flag
LIBERIA
Maury page id
psix-614227

Documentation record

Tonnage as PSIX records it17840 - Convention (Subpart B), Gross Ton
23495 - Dead Weight, Metric Ton
33021 - Displacement, Metric Ton
5352 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

17 May 2025 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8135753
23 May 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7918091
19 February 2024 PSC B · COC-GAS Annual · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7867223
8 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7763228
14 February 2023 PSC B · Ballast Water Examination · COC-GAS Renew · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7631534
29 June 2022 PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7489850
27 December 2021 COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7372464
19 May 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7200918
9 April 2021 PSC B · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7172108
6 October 2020 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7068910
10 May 2019 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6675423
1 August 2017 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6221737
3 February 2016 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5800482
30 January 2016 In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5799430

Deficiency record · 6

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 February 2024 Resolved
A gas carrier shall comply with the requirements of the IGC. In zones on open decks with 3m of any cargo tank outlet...the following may be installed: certified safe type equipment and through runs of cables. PSCO observed the following: #2 stbd cargo pump junction box glands not certified safe, 01 light above #2P cargo tank was not able to be determined if it was certified safe, unapproved splice on electrical light cabling in the crossover manifold. Identified multiple instances of dead end cabling on light fixtures throughout cargo area.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 May 2024
Resolution: Vessel submitted Class Report attesting to corrections and repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 February 2023 Resolved
Where electrical equipment is installed in gas dangerous spaces or zones it should be to the satisfaction of the administration and approved by the relevant authorities recognized by the administration for operation in the flammable atmosphere. While conducting the deck walk PSCOs observed 2 certified safe lights with deteriorated cable couplings located on the COT 4 Port & starboard exterior compressor room bulkhead. Additionally, 5 cracked lights were found in the cargo compressor room. SOLAS 74 2020 consolidated Chapter VII Reg 13.1, 1993 IGC Code Chapter 10.1.5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 August 2023
Resolution: Class report submitted to attest repairs were made. (Class report attached)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 February 2023 Resolved
Where electrical equipment is installed in gas dangerous spaces or zones it should be to the satisfaction of the administration and approved by the relevant authorities recognized by the administration for operation in the flammable atmosphere. During the deck walk PSCOS observed cargo pump cable penetrations to no longer be gastight on COT 3 Port and starboard. SOLAS 74 2020 consolidated Chapter VII Reg 13.1, 1993 IGC Code Chapter 10.1.5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 August 2023
Resolution: Class report submitted to attest repairs were made. (Class report attached)
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 17 February 2023 Resolved
The liferafts on at least one side of the ship shall be serviced by a launching appliance. Port side davit launched liferafts cannot be launched due to davit brake being inoperable. Solas 74 (2020) CH III Reg 31.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2023
Resolution: Class report was submitted attesting to the safe operation of davitt & break.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 April 2021 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Notice free fall lifeboat propulsion was not engaging forward or astern.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2021
Resolved 15 April 2021
Resolution: Crew was able to correct issue on the free fall lifeboat, PSCO witnessed the propulsion engaged forward and astern successfully several times satisfactory.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 30 January 2016 Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 3 February 2016

Ownership record