AURORA

AURORA is a 2003 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2003, most recently in April 2026, along with 61 deficiencies and 2 casualty investigations between 2016 and 2024.

Records from 2003 to 2026. Most recent: inspection, 16 April 2026.

Built
2003
Last inspected
16 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP6683
614231
Flag
UNITED STATES
366895830
Maury page id
psix-614231

Inspections, by type

…with no type recorded3
Years with a record 20 calendar years (2003–2026)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)34.0 ft × 12.0 ft × 5.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBUFFALO BOATS INC · BELLINGHAM, WA, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portREQUA, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP6683MMSI 366895830 · active · compulsorily equipped · granted 21 June 2024, expires 21 June 2034
WDB4196MMSI 366895830 · expired · compulsorily equipped · granted 14 March 2013, cancelled 5 August 2023
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 34

16 April 2026 Inclining Experiment
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8354833
25 November 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8273880
21 September 2024 Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 8006848
21 September 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8023520
27 August 2024 COI Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7987794
10 June 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7932571
30 October 2023 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7816709
15 August 2023 Administrative Inspection
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7768575
23 August 2022 Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7542492
27 July 2022 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7516115
23 May 2022 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7457353
21 September 2021 Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7319043
26 August 2021 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7297366
9 April 2021 Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7172128
11 June 2020 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6986872
26 May 2020 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6963078
7 October 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6830255
23 September 2019 Damage Survey
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6820337
20 March 2019 Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6646715
4 June 2018 COI Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6434386
5 April 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6390692
1 June 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6181815
25 August 2016 COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6028934
31 May 2016 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6007959
19 April 2016 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5853380
23 September 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5727187
19 June 2014 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4947195
29 May 2012 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4341089
6 May 2009 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3474455
15 April 2008 DAPI Audit · Internal Structural Exam · COI Inspection · MARPOL Annex V Examination · Drydock Exam · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3190155
22 October 2007 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3087024
27 April 2006 Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2679828
11 May 2004 Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2109756
27 June 2003 Construction Oversight · Simplified Stability Test · Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1782579

Deficiency record · 61

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2024 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. The vessel was not fully manned as specified by the certificate of inspection and was unable to satisfactorily demonstrate the required drills. Drills shall be conducted in the presence of a Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2024
Resolution: Coast Guard Marine Inspector witnessed crew perform satisfactory drills on 06 Sept 2024.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 August 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. (b) Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers. (c) A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The required high water visual and audible alarms were not functioning. Repair the high water alarms so they are functioning with a visual an audible indicator at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2024
Resolution: Coast Guard Marine Inspector verified all high bilge level alarms were working as required.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 July 2022 Resolved
This vessel is required to have three (3) Fire Buckets with lanyards. Make available all three (3) buckets for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2022
Resolution: Corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 July 2022 Resolved
The FCC Safety Radio Certificate is expired. Make available an updated certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2022
Resolved 23 August 2022
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 July 2022 Resolved
All radiotelephones must contain integral GPS capabilities or must be connected to an electronic position-fixing device. Connect all onboard VHF radios to GPS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2022
Resolved 7 September 2022
Resolution: Properly installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 July 2022 Resolved
Fuel shutoff valves must be fitted in the fuel lines to stop fuel flow in the event of an emergency. The STBD fuel shutoff valve did not close using the remote fuel shutoff pull station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2022
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 26 August 2021 Resolved
Improperly installed life raft. Life raft painter was not connected to the hydrostatic release and would not have activated in an emergency.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 August 2021
Resolved 26 August 2021
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 August 2021 Resolved
Vessel must provide a crew for drills and underway tests prior to carrying passengers. Company does not intend to use vessel again this season. date extended to next operating season for completion, NLT May 30, 2022
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2022
Resolved 27 July 2022
Resolution: Discussed crew drills
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 August 2021 Resolved
Epirb hydrostatic release expired in June 2021. Provide a new hydrostatic release. Vessel is limited to operating in waters withing 3 NM's of shore.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 30 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 August 2021 Resolved
Provide a vapor tight seal for the exhaust thru bulkhead locations in the aft engine room bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 21 September 2021
Resolution: Thru bulkhead sealed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 August 2021 Resolved
Excessive oil on the forward engine room bulkhead and components is creating a fire hazard. Clean areas and make available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 21 September 2021
Resolution: excessive oil cleaned up
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 26 August 2021 Resolved
Cracking noted in the port and starboard stepped up deck areas on either side of the aft bulkhead of the pilot house/accom space. The cracking will need to be repaired at the next Drydock which is due 30APR2022.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 1 April 2022
Resolution: Cracking repaired
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2019 Resolved
Provide 03 Fire Buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Provided 03 fire buckets.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 October 2019 Resolved
Update First Aid Kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Updated First Aid Kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2019 Resolved
Provide adequate line for ring buoy light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Ring Buoy all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2019 Resolved
Bonding on Steering System is broken.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Bonding reattached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 7 October 2019 Resolved
Renew cracked window (starboard aft).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Window Replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2019 Resolved
Adjust stbd fuel shut off to ensure complete closure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Fuel shut off closes correctly.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 June 2018 Resolved
automatic bildge pumps were not able to work
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2018
Resolved 5 June 2018
Resolution: working condtion, tested by USCG
Navigation › Piloting/Steering › Marine Charts
Issued 7 June 2017 Resolved
Provide updated charts for applicable area of operations. 46 CFR 184.420
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 14 June 2017
Resolution: Updated charts were provided
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 June 2017 Resolved
Provide original copy of liferaft servicing certificated on board vessel. 46 CFR 180.200
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 14 June 2017
Resolution: Liferaft servicing certificate was provided
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 June 2017 Resolved
Tighten metal clamps on stbd main diesel exhaust. Clean around exhaust area. Wipe excess oil. 46 CFR 182.430(f)
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 14 June 2017
Resolution: Metal clamp was tighten on STBD exhaust.
Engineering › Bilge Water Management System › Valve
Issued 7 June 2017 Resolved
Provide stop valves at sideshell on electric bilge pump piping in main cabin bilge. 46 CFR 182.520(e)(7)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 14 June 2017
Resolution: Valve was added to the bilge pump overboard.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 19 April 2016 Resolved
Replace both shaft bearings
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 10 May 2016
Resolution: replaced bearings
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 19 June 2014 Resolved
Provide radio operator license for master
Action required: 705 - Other - as specified
Resolved 28 August 2014
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 19 June 2014 Resolved
Stencil 1 PFD
Action required: 705 - Other - as specified
Resolved 28 August 2014
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 June 2014 Resolved
Remove extra lifering or properly stencil & provide solas tape
Action required: 705 - Other - as specified
Resolved 28 August 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 June 2014 Resolved
Remove expired items from first aid kit and replace.
Action required: 705 - Other - as specified
Resolved 28 August 2014
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 May 2012 Resolved
Segregate child and adult life jackets.
Due 12 June 2012
Resolved 12 July 2012
Resolution: Segregated.
Construction/Loadline › Penetrations › Pipe Flange
Issued 29 May 2012 Resolved
Seal bulkhead penetration where hot water hoses penetrate forward bulkhead of engine room.
Due 12 June 2012
Resolved 12 July 2012
Resolution: Sealed
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 29 May 2012 Resolved
Flexible hose for fuel supply and return lines must be made to meet 46 CFR 182.720(e) + (f).
Due 12 June 2012
Resolved 12 July 2012
Resolution: Replaced with approved hose.
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 May 2012 Resolved
Replace flexible hose between strainer and starboard engine in kind.
Due 12 June 2012
Resolved 12 July 2012
Resolution: Replaced.
Engineering › Bilge Water Management System › Pump
Issued 21 May 2008 Resolved
Repair/replace automatic bilge pump float switch IWO laz.
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 6 June 2008
Resolution: Float switch was replaced and bilge/alarm operationally tested sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 May 2008 Resolved
Move fuel shutoff and vent shutoff labels to readable loactions.
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 6 June 2008
Resolution: labels were moved to an easily readable location.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2008 Resolved
Repair/remove dead end wired behind dash.
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 21 May 2008
Resolution: Dead end wires were secured and bundled properly.
Communications › Radio Communications › EPIRB
Issued 14 May 2008 Resolved
Provide 406 Cat. 1 EPIRB w/ current battery and hydo release. *Note* EPIRB was not on vsl at inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2008
Resolved 21 May 2008
Resolution: EPIRB was provided w/ current battery, hydo, NOAA registration.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 May 2008 Resolved
Provide light list or applicable excerpts.
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 21 May 2008
Resolution: Excerpt of light list were provided.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 14 May 2008 Resolved
Lock MSD O/B discharge valve.
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 21 May 2008
Resolution: MSD O/B discharge was properly secured.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 May 2008 Resolved
Povide visual indicators for high water alarms.
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 21 May 2008
Resolution: Panel was installed w/ visual indicators for all high lvl alarms.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 May 2008 Resolved
Provide serviced fire ext. at operating station.
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 21 May 2008
Resolution: Service portable fire ext. was provided at operating station.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 May 2008 Resolved
Repair remote fuel shut-off. *Note* during remote fuel operatin test the cable that operates the valves parted due to corrosion.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2008
Resolved 21 May 2008
Resolution: Cable was replaced, successful test of remote fuel shut-offs was witnessed to the satisfaction of attending marine inspector.
Construction/Loadline › Hull › Collision Chock
Issued 14 May 2008 Resolved
make collision bulkhead watertight. *note* an access had been cut for O/O to have access to space forward of collision bulkhead (chain locker). This access was not watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2008
Resolved 21 May 2008
Resolution: Access was properly sealed using oversized plywood backing and gasket material to the satisfaction of attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2008 Resolved
Repair/remove dead end wires behind cabin door.
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 21 May 2008
Resolution: Dead end wires were secured and bundled to the satisfaction of attending marine inspector.
Engineering › Steering Gear System › Linkage
Issued 14 May 2008 Resolved
Repair port rudder post mounting block and provide bonding. *note* while U/W conducting drills the port rudder post mount was loose providing shifting/vibration during steering system test.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2008
Resolved 21 May 2008
Resolution: Port rudder post block was reinforced with new/additional fastners to the satisfaction of attending marine inspector. O/O said that both would be replaced at next DD.
Construction/Loadline › Hull › Bracket
Issued 14 May 2008 Resolved
Repair lifting ring on E/R access deck hatch.
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 21 May 2008
Resolution: Lifting ring was replaced and properly installed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 May 2008 Resolved
Crew clearly unprepared for drills. Both fire and MOB drills unsat. Provide crew for drills at 2nd COI inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2008
Resolution: Crew was trained on drills and completed satisfactory MOB and fire drill to the satisfaction of attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2008 Resolved
Cover electrical connections behind dash.
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 6 June 2008
Resolution: Box was built and secured in place to properly cover electrical connections behind dash.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 April 2008 Resolved
Vessel did not complete 4th annual inspection, that was due in 2007. Vessel is restricted from carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2008
Resolved 21 May 2008
Resolution: Vsl completed unsatisfactory annual inspection, COI was officially revoked. Vsl to compete COI inspection.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 October 2007 Resolved
Complete vessels annual inspection & drills prior to operating with vessel COI / passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2008
Resolution: Vsl completed unsat annual inspection, COI was officially revoked. Vsl to complete COI inspection in the future.
Documentation › Certificates/Documents › FCC SSL
Issued 27 April 2006 Resolved
Provide FCC safety certificate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 22 February 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 27 April 2006 Resolved
Missing aft transom door.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2006
Resolved 22 February 2007
Engineering › Fuel Oil Service System › Discharge Strainer
Issued 27 April 2006 Resolved
Provide approved marine type fuel strainers for p/s main engines.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 22 February 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 27 April 2006 Resolved
Replace cracked windows in passenger seating area.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 22 February 2007
Resolution: Cracked window was replaced.
Construction/Loadline › Penetrations › Gasket
Issued 27 April 2006 Resolved
Make engine room bulkhead fume tight.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 22 February 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 April 2006 Resolved
Provide battery cover of an approved size to cover battery box.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 22 February 2007
Resolution: An appropriately sized cover was installed.
Communications › Audible Communications › Horn/Whistle
Issued 11 May 2004 Resolved
Provide a proper sound signaling device.
Due 11 June 2004
Resolved 2 June 2004
Resolution: Horn repaired.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 May 2004 Resolved
Provide current navigation publications, charts, coast pilot and tide and current tables.
Due 11 June 2004
Resolved 2 June 2004
Resolution: Items onboard vessel.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 11 May 2004 Resolved
Post an oil polution placard onboard.
Due 11 May 2004
Resolved 2 June 2004
Resolution: Item posted.
Documentation › Markings/Placards › Injury Placard
Issued 11 May 2004 Resolved
Post lifejacket donning placard.
Due 11 June 2004
Resolved 2 June 2004
Resolution: Placard posted.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 May 2004 Resolved
Post an Emergency Broadcast placard at the operating station.
Due 11 June 2004
Resolved 2 June 2004
Resolution: Emergency Broadcast placard posted.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 May 2004 Resolved
Register the EPIRB with NOAA and provide proof of registration.
Due 11 June 2004
Resolved 2 June 2004
Resolution: EPIRB registered.

Casualty record · 2

31 May 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6007959
21 September 2024Routine · role: Involved in a Marine Casualty · activity 8023520
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.