Records from 2016 to 2026. Most recent: inspection, 16 April 2026.
Inspection history · 25
16 April 2026
Inclining Experiment
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8354833
25 November 2025
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8273880
21 September 2024
Type not recorded
No type recorded · Station Grays Harbor · USCG Northwest District (CGD-NW) · Activity 8006848
21 September 2024
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8023520
27 August 2024
COI Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7987794
10 June 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7932571
30 October 2023
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7816709
15 August 2023
Administrative Inspection
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7768575
23 August 2022
Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7542492
27 July 2022
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7516115
23 May 2022
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7457353
21 September 2021
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7319043
26 August 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7297366
9 April 2021
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7172128
11 June 2020
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6986872
26 May 2020
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6963078
7 October 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6830255
23 September 2019
Damage Survey
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6820337
20 March 2019
Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6646715
4 June 2018
COI Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6434386
5 April 2018
Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6390692
1 June 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6181815
25 August 2016
COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6028934
31 May 2016
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6007959
19 April 2016
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5853380
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2024
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. The vessel was not fully manned as specified by the certificate of inspection and was unable to satisfactorily demonstrate the required drills. Drills shall be conducted in the presence of a Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2024
Resolution: Coast Guard Marine Inspector witnessed crew perform satisfactory drills on 06 Sept 2024.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 August 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:
(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;
(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and
(3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck.
(b) Vessels constructed of wood must, in addition to paragraph (a), provide bilge level alarms in all watertight compartments except small buoyancy chambers.
(c) A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.
The required high water visual and audible alarms were not functioning. Repair the high water alarms so they are functioning with a visual an audible indicator at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2024
Resolution: Coast Guard Marine Inspector verified all high bilge level alarms were working as required.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 July 2022
Resolved
This vessel is required to have three (3) Fire Buckets with lanyards. Make available all three (3) buckets for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2022
Resolution: Corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 July 2022
Resolved
The FCC Safety Radio Certificate is expired. Make available an updated certificate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2022
Resolved 23 August 2022
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 July 2022
Resolved
All radiotelephones must contain integral GPS capabilities or must be connected to an electronic position-fixing device. Connect all onboard VHF radios to GPS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2022
Resolved 7 September 2022
Resolution: Properly installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 27 July 2022
Resolved
Fuel shutoff valves must be fitted in the fuel lines to stop fuel flow in the event of an emergency. The STBD fuel shutoff valve did not close using the remote fuel shutoff pull station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2022
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 26 August 2021
Resolved
Improperly installed life raft. Life raft painter was not connected to the hydrostatic release and would not have activated in an emergency.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 August 2021
Resolved 26 August 2021
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 August 2021
Resolved
Vessel must provide a crew for drills and underway tests prior to carrying passengers. Company does not intend to use vessel again this season. date extended to next operating season for completion, NLT May 30, 2022
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2022
Resolved 27 July 2022
Resolution: Discussed crew drills
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 August 2021
Resolved
Epirb hydrostatic release expired in June 2021. Provide a new hydrostatic release. Vessel is limited to operating in waters withing 3 NM's of shore.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 30 August 2021
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 August 2021
Resolved
Provide a vapor tight seal for the exhaust thru bulkhead locations in the aft engine room bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 21 September 2021
Resolution: Thru bulkhead sealed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 August 2021
Resolved
Excessive oil on the forward engine room bulkhead and components is creating a fire hazard. Clean areas and make available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2021
Resolved 21 September 2021
Resolution: excessive oil cleaned up
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 26 August 2021
Resolved
Cracking noted in the port and starboard stepped up deck areas on either side of the aft bulkhead of the pilot house/accom space. The cracking will need to be repaired at the next Drydock which is due 30APR2022.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 1 April 2022
Resolution: Cracking repaired
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2019
Resolved
Provide 03 Fire Buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Provided 03 fire buckets.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 October 2019
Resolved
Update First Aid Kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Updated First Aid Kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 October 2019
Resolved
Provide adequate line for ring buoy light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Ring Buoy all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2019
Resolved
Bonding on Steering System is broken.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Bonding reattached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 7 October 2019
Resolved
Renew cracked window (starboard aft).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Window Replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2019
Resolved
Adjust stbd fuel shut off to ensure complete closure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Fuel shut off closes correctly.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 June 2018
Resolved
automatic bildge pumps were not able to work
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2018
Resolved 5 June 2018
Resolution: working condtion, tested by USCG
Navigation › Piloting/Steering › Marine Charts
Issued 7 June 2017
Resolved
Provide updated charts for applicable area of operations. 46 CFR 184.420
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 14 June 2017
Resolution: Updated charts were provided
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 June 2017
Resolved
Provide original copy of liferaft servicing certificated on board vessel. 46 CFR 180.200
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 14 June 2017
Resolution: Liferaft servicing certificate was provided
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 7 June 2017
Resolved
Tighten metal clamps on stbd main diesel exhaust. Clean around exhaust area. Wipe excess oil. 46 CFR 182.430(f)
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 14 June 2017
Resolution: Metal clamp was tighten on STBD exhaust.
Engineering › Bilge Water Management System › Valve
Issued 7 June 2017
Resolved
Provide stop valves at sideshell on electric bilge pump piping in main cabin bilge. 46 CFR 182.520(e)(7)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 14 June 2017
Resolution: Valve was added to the bilge pump overboard.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 19 April 2016
Resolved
Replace both shaft bearings
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 10 May 2016
Resolution: replaced bearings