Records from 2009 to 2024. Most recent: inspection, 25 October 2024.
Documentation record
Registered dimensions (L × B × D)62.3 ft × 18.2 ft × 7.7 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTIDEWATER TRANSPORTATION · ATTALIA, WA, UNITED STATES · built 1941
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portVANCOUVER, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 8
25 October 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8013158
5 October 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7803451
15 November 2022
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7594602
23 July 2021
Deficiency Check · Initial Certification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7263832
15 August 2016
Industry Initiated Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5973843
1 November 2012
Risk-based Targeted Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4481425
16 October 2012
Administration
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4465350
16 September 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3626853
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Marine Inspector observed that the Port side Main Engine had exhaust leak coming off of the turbo. Make corrective actions to exhaust leak and observed by Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 5 November 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 August 2021
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the The system is installed, tested, and maintained in accordance with the manufacturer's design manual and the design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience. Vessel must provide evidence of certification of the installed fire detection system prior to conducting towing operations. 46CFR142.330 (a)(2)-(8).
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 August 2021
Resolution: Received certification of approval and operational test for the fire detection system.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 17 August 2021
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Alarms and set points must be provided for main engine and auxiliary generator low lubricating oil pressure and must be tested at least twice every five years. Vessel was unable to test low lube oil pressure or demonstrate set points for alarms. Demonstrate alarms and set points prior to conducting towing operations. 46CFR 143.230(a)(1)&(3) and 46CFR 143.245.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 August 2021
Resolution: Witnessed operational test of low lube oil alarms for main engines and generator.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 August 2021
Resolved
Each towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage as listed in the noted regulations. Provide required charts and publications prior to conducting towing operations. 46 CFR 140.705, 33 CFR 164.72, 33 CFR 83.01.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 August 2021
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 17 August 2021
Resolved
Towing vessels must identify the duties and duty stations of each person on board during an emergency, and post at each operating station and in a conspicuous location in a space commonly visited by crew members. Provide watch station bill as required prior to towing operations. 46 CFR 140.405(c)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 August 2021
Resolution: Observed emergency duty responsibilities for the crew posted in the galley.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 17 August 2021
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crew members to include education and training on drug use. Each EAP education program must include display and distribution of informational material, community service hot-line telephone number for crew member assistance, and the employer's policy regarding drug and alcohol use in the workplace. Display information on board prior to towing operations. 46 CFR 16.401
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 August 2021
Resolution: EAP information posted in the galley.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 July 2021
Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel. Marine Inspectors identified the following items in the forepeak which bring into question the seaworthiness and fitness of the vessel: Large inset on starboard side hull plating, broken/missing structural members throughout the space, failing doubler plates. Vessel is required to make satisfactory repairs and conduct a drydock and internal structural exam to the satisfaction of an attending Coast Guard Marine Inspector prior to movement.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 July 2021
Resolution: Operator cropped out the inset area and renewed with new framing, lapped plate at the chine and hull side to bottom joint, copying original construction using backing bars of transverse butt joint and adding additional framing in way of the new plate.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 23 July 2021
Resolved
Safety orientations and other crew training must be documented in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel. Vessel could not produce records of any safety trainings or orientations specific to the vessel. Conduct required crew safety orientation/training prior to movement.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 August 2021
Resolution: Observed safety orientation and crew training documents completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Marine Inspectors identified an ASME 200 psi MAWP pressure vessel piped in parallel with a non ASME 140 psi MAWP pressure vessel with a one way check valve as the only failsafe isolating the two systems. The relief valve on the smaller pressure vessel was set at 125 psi. If the check valve were to fail a significant risk of explosion exists.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 August 2021
Resolution: Observed piping modifications to isolate the two pressure vessels in line with relief valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 July 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Marine Inspectors identified the air intake emergency closure disabled on the Detroit auxiliary generator. Operator must reinstall the closure device so that in the event of an emergency the generator may be shut down.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 August 2021
Resolution: Observed air intake intake emergency closure operating properly.