Records from 2003 to 2026. Most recent: inspection, 25 February 2026.
Inspection history · 19
25 February 2026
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8322810
16 January 2025
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8064482
22 February 2024
Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7857180
8 March 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7637955
22 February 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7392259
5 March 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7139996
19 February 2020
Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6894789
26 February 2019
Drydock Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6630554
20 February 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6337186
21 February 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6087710
6 May 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5869912
8 March 2016
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5829027
23 February 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5817343
14 May 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4304743
6 July 2011
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4060473
21 April 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3180799
7 August 2006
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2739038
6 April 2005
Hull Examination · COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2326867
23 April 2003
Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1768142
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 February 2022
Resolved
46 CFR 185.614: Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least .5" high: "DISTRESS SIGNALS". Marine inspector found portable watertight container not marked.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2022
Resolution: Company rep properly marked the distress flare box.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 February 2022
Resolved
46 CFR 180.70(d): A vessel must carry one floating waterlight, unless it is limited to daytime operation. Inspector found waterlight battery expired. Vessel is restricted to daytime operations only until new "approved" battery is placed.
Action required: 10 - Deficiency Rectified
Resolved 22 February 2022
Resolution: Rectified prior to CG departure
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 February 2022
Resolved
33 CFR 83.23(d): A power driven vessel of less than 12 meters in length may, in lieu of the lights prescribed in paragraph (a) of this Rule, exhibit an all-round white light and side lights. MI discovered the vessel's installed canopy extending higher than the all-round white light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2022
Resolution: Light was raised, extending above the canopy.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 February 2022
Resolved
46 CFR 180.68(b)(1): Lakes, Bays and sounds, and Rivers routes. A vessel must carry three hand red flares. MI found 01 expired flare.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2022
Resolution: Company rep replaced the expired flares with new flares.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 March 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
Contents of first aid kit were expired.
Action required: 10 - Deficiency Rectified
Due 5 March 2021
Resolved 5 March 2021
Resolution: Expired contents replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021
Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either §160.002, §160.005, or §160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176.
Retroflective tape is delaminated and needs to be replaced on child life jackets.
Action required: 10 - Deficiency Rectified
Due 5 March 2021
Resolved 5 March 2021
Resolution: Retroreflective tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 March 2021
Resolved
Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry:
Three hand red flare distress signals approved in accordance with §160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and
Three hand orange smoke distress signals approved in accordance with §160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
A hand red flare distress signal approved in accordance with §160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121 may substitute for hand orange smoke distress signals.
Vessel only had 1 hand red flare on board.
Action required: 10 - Deficiency Rectified
Due 5 March 2021
Resolved 5 March 2021
Resolution: Replenished missing red hand flares.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 21 February 2017
Resolved
Anchor was missing.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Anchor was provided to the vessel.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 February 2017
Resolved
Stern light was mounted to low to be visible.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 28 February 2017
Resolution: Stern light was mounted higher.
Construction/Loadline › Hull › Hull Plating
Issued 8 March 2016
Resolved
Vessel was in a collision and had the port side bow ripped open about 1 foot and some welds cracked and the forward railing ripped off. Repair prior to ops.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2016
Resolution: Repairs made to the satisfaction of the attending MI.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 23 February 2016
Resolved
Portable fire extinguisher found discharged. Corrected on the spot to satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 23 February 2016
Resolution: Replaced fire extinguisher to satisfaction of attending Marine Inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 February 2016
Resolved
First Aid kit found with x2 waterlogged components. Corrected on the spot to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 26 February 2016
Resolved 23 February 2016
Resolution: Replaced damaged pieces to the satisfaction of attending Marine Inspector.
Documentation › Markings/Placards › Vessel Number (state)
Issued 6 April 2005
Resolved
Vessel must properly mark hull with vessel name and state numbers.
Condition: Unknown
Due 13 April 2005
Resolved 8 April 2005
Lifesaving › Lifebuoys › Serviceable
Issued 6 April 2005
Resolved
Vessel must replace lifebuoy to include a 60ft lifeline and a (properly functioning) light float with detachable 3-6ft lanyard.
Condition: Unknown
Due 13 April 2005
Resolved 8 April 2005
Lifesaving › Hand Flares › Not on Board
Issued 6 April 2005
Resolved
Vessel required to have 3 red flares and 3 orange smokes.
Condition: Unknown
Due 13 April 2005
Resolved 8 April 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 April 2005
Resolved
Vessel required to post lifejacket donning procedures.
Condition: Unknown
Due 13 April 2005
Resolved 8 April 2005