Records from 2016 to 2026. Most recent: inspection, 14 May 2026.
Inspection history · 13
14 May 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8376133
12 June 2025
Initial Certification · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8151089
31 March 2025
Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8100485
23 April 2024
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7899896
30 March 2023
Hull Examination · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7659248
13 April 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7418691
31 March 2021
Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7154827
1 June 2020
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6967666
11 April 2019
Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6648434
6 June 2018
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6435702
4 April 2018
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6375804
12 April 2017
Hull Examination · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6099518
22 March 2016
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5837962
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 March 2023
Resolved
First aid kit which meets meets ISO 18813 must be onboard while operating. Vsl first aid kit was waterlogged and had several expired items contained. Vsl must provide serviceable first aid kit. 46 CFR 184.710
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2023
Resolution: First Aid Kit repleneshed with serviceable meds.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 March 2023
Resolved
A serviceable waterlight battery must be provided for life ring waterlights. Battery in waterlight was expired. Vsl must provide a serviceable battery or replace waterlight with other approved model. 46 CFR 180.70(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2023
Resolution: New waterlight battery provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 March 2023
Resolved
Liferings must be serviceable iaw approval specification. Vsl forward life ring water plug was wasted. Vsl must provide a serviceable life ring. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2023
Resolution: New lifering provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 March 2023
Resolved
Life rings must be properly stowed and readily accessible. Vsl aft lifering laying on deck and not readily accessible for rapid deployment. VSl must provide means for proper stowage of life ring. 46 CFR 180.70(b)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2023
Resolution: Lifering stowed in a readily deployable position.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 March 2023
Resolved
Connections in fuel lines must be properly secured. Vsl missing two hose clamps in fuel supply line to outboard engine. Vsl must secure fuel lines using appropriate sized pipe clamps not zip ties. 46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2023
Resolution: Additional hose clamps provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 March 2023
Resolved
Portable fuel systems must meet the requirements of ABYC H-25. Vsl STBD portable fuel tank is cracked. Vsl must provide a serviceable portable fuel tank which meets the requirement of ABYC standard H-25. 46 CFR 182.445
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 April 2023
Resolution: New ABYC approved gas can provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 March 2023
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color. Storage container on vessel is dark green. Vsl must provide a bright colored watertight storage container for the distress signals. 46 CFR 185.614
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2023
Resolution: Master attested to attending [name withheld] container was painted a bright color.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2022
Resolved
A vessel must carry one floating waterlight unless it is limited to daytime operation. Each floating waterlight must be approved in accordance with 46 CFR 161.010. Vessel's waterlight has no markings indicating approval in accordance with 46 CFR 161.010. Replace waterlight with an approved type. Vessel is restricted to daytime operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 13 April 2022
Resolution: Vessel's owner purchased and installed new waterlight.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and other at the access to the propulsion machinery space. Vessel has one portable light which is inoperable. Provide two operating portable lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 13 April 2022
Resolution: Vessel's owner provided two operable portable battery lights.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 April 2022
Resolved
A vessel must comply with applicable requirements for any radio installation. Vessel's radio is not programmed with MMSI nor is it connected to GPS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 15 April 2022
Resolution: Vessel owner emailed pictures providing proof of remaining outstanding deficiency corrected. All SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 March 2021
Resolved
Prove test strips and date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 14 April 2021
Resolution: Provided photo of strips onboard
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 31 March 2021
Resolved
Provide NAV RULES
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 28 April 2021
Resolution: NAV RULES BOOK ONBOARD
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 March 2021
Resolved
Provide Light list
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 14 April 2021
Resolution: Provided Light List onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2021
Resolved
Renew fuel line from engine to filter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 28 April 2021
Resolution: New fuel line installed
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 March 2021
Resolved
Renew ring buoy life line wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 28 April 2021
Resolution: New ring buoy installed
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 March 2021
Resolved
Renew float light battery (expired and working)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 14 April 2021
Resolution: Float light battery replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2020
Resolved
Found 02 substandard lifejackets due to sun damage.
Action required: 10 - Deficiency Rectified
Resolved 1 June 2020
Resolution: Replaced with new and proper markings
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2020
Resolved
First aid kits not CG approved.
Action required: 10 - Deficiency Rectified
Due 1 June 2020
Resolved 1 June 2020
Resolution: Replaced with new. Operator provided photos.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 11 April 2019
Resolved
Repair damaged FRP IWO rubrails P&S FWD & port aft.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 11 May 2019
Resolved 6 May 2019
Resolution: Repaired
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 11 April 2019
Resolved
C&R deteriorated/delaninated section of bow-cap.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 6 May 2019
Resolution: Repaired
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 11 April 2019
Resolved
Repair fractured aluminum canopy top (two places port side)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 6 May 2019
Resolution: Rewelded
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 11 April 2019
Resolved
Grind & repair delaminated FRP seats IAW best practices.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2019
Resolved 6 May 2019
Resolution: Repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2019
Resolved
Renew retroflective tape IWO 1 lifejacket.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 6 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 April 2019
Resolved
Renew hose clamps IWO fuel hoses (corroded & missing)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 6 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2019
Resolved
Renew ring buoy line due to UV deterioration.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 6 May 2019
01 - Certificates & Documentation › 013 - Documents › Fire safety operational booklet
Issued 11 April 2019
Resolved
Provide new no smoking placard.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 6 May 2019
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 April 2018
Resolved
Provide approved 2 approved child life jackets w/ USCG 160 approval #. The current 9 jackets are only solas approved & are not reversable. Apply retroflective tape IWO the reverse side until approved jackets are ordered & onboard.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2018
Resolved 6 June 2018