MAURY USCG vessel records
← All vessels

MATHRAKI

Built
2003
Last inspected
24 April 2019
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 April 2019
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9262948
614768
Flag
GREECE
Maury page id
psix-614768

Documentation record

Tonnage as PSIX records it19621 - Dead Weight, Metric Ton
27382 - Displacement, Metric Ton
16770 - Convention (Subpart B), Gross Ton
5031 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 12 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

24 April 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6669969
20 April 2019 COE-Administrative · Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6665987
19 April 2019 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6666318
16 January 2019 COE-Administrative
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6610595
19 December 2018 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6600324
19 October 2018 COC-GAS Renew · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6562932
19 January 2018 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6342351
14 January 2018 In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6337782
9 January 2018 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6335056
5 November 2017 ISPS II Exam · COC-GAS Annual · Ballast Water Examination · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6301098
5 November 2017 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6327026
11 October 2016 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6020365

Deficiency record · 5

10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 19 October 2018 Resolved
All ships over 150 gross tonnage when engaged in international voyages shall have on board an efficient daylight signaling lamp, which shall not be solely dependent upon the ship's main source of electrical power. The vessel's daylight signaling lamp operates solely on the ship's power. 74SOLAS(01) V/19.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2018
Resolved 19 December 2018
Resolution: Verified deficiency corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 October 2018 Resolved
Each hose shall be provided with the necessary couplings. During fire drill a hose parted and the exam was expanded. An additional hose on the main deck parted, due to improper installation. 74SOLAS(01) II-2/4.7.1
Action required: 10 - Deficiency Rectified
Due 19 October 2018
Resolved 19 October 2018
Resolution: Deficiency was rectified before exam team left vessel.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 November 2017 Resolved
An audible and visual alarm shall be provided to give warning on both sides of airlock when more than one door is moved from the closed position.PSCO discovered that the airlock did no produce an audible alarm on either side of the airlock when both doors were open. IGC Code 3.6
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Resolved 11 November 2017
Resolution: SEC HOU-GAL PSC received a class report from ABS satisfying the requirement
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 November 2017 Resolved
A permanently installed system for gas detection and visual and audible alarms shall be installed. PSCO observed the gas detection LEL readings in the cargo control room did not match the span gas used or the local readings at each gas detector. IGC Code 13.6
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 11 November 2017
Resolution: SEC HOU-GAL PSC received a class report from ABS satisfying the requirement
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 5 November 2017 Resolved
Water spray system for cooling fire prevention shall be fitted to cover each manifold. PSCO observed the water spray system at the manifold on both port and starboard sides only spray on the cargo piping and does not reach the manifold or drip trays under manifold. IGC Code 11.3
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 9 January 2018
Resolution: Recieved correspondence between LGC NCOE and Company, Team Lead accepts repair.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.