Records from 2012 to 2024. Most recent: operational control imposed, 5 November 2024.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)76.0 ft × 14.0 ft × 9.2 ft
Registered tonnagegross 48 / net 44
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORE BUILDERS INC · VENTURA, CA, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Simplified, Gross Ton
44 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
5 November 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8029816
16 December 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7851905
23 October 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7812802
19 January 2023
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7622553
7 November 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7590478
16 June 2022
Damage Survey · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7479713
19 April 2022
Plan Review "T" Boat · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7435063
27 March 2022
Administrative Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7419547
27 March 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7559920
9 August 2021
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7269420
30 July 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7281800
18 February 2021
Internal Structural Exam · Hull Examination · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7142649
20 January 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7127838
23 December 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7115808
15 October 2020
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7078101
18 May 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6955555
31 January 2020
Internal Structural Exam · Administrative Inspection · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6904114
17 September 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6810069
28 August 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6512667
29 January 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6339371
25 September 2017
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6272769
26 January 2017
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6080328
9 August 2016
COI Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5962404
3 June 2016
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5896614
4 January 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5790833
4 January 2016
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5790862
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 November 2024
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. During operational test of pre-engineered fire extinguishing system shutdown, operator was unable to override shut down and restart engines. 46 CFR 181.420(b)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2024
Resolved 18 November 2024
Resolution: Vessel replaced overide switch all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 November 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. MI observed portable fire extinguisher improperly mounted in unauthorized bracket on main deck, port side. 46 CFR 181.500(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2024
Resolved 18 November 2024
Resolution: Installed correct bracket for extinguisher.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2024
Resolved
All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. MI observed electrical cable supports forward of batteries unsecured from mounts in vicinity of keel. 46 CFR 183.340(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2024
Resolved 18 November 2024
Resolution: Properly secured cables all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 5 November 2024
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: A hatch on a vessel that operates only on protected waters. MI observed gasket for lazarette hatch missing a piece and not weathertight. 46 CFR 179.360(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2024
Resolved 18 November 2024
Resolution: Vessel repaired gasket all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 5 November 2024
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: General description of the drill scenario and training topics. MI observed drills being logged without general description of drill scenario or topic. 46 CFR 185.524(d)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2024
Resolved 18 November 2024
Resolution: Verified logbook entry for drills.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 7 November 2022
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight. The hatches leading below deck were not weathertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2022
Resolved 7 December 2022
Resolution: Verified weathertight integrity of hatches.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 June 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions of a seaworthy hull. Vessel allided with dock resulting in hull damage ivo forestay chain plate. Submit repair proposal and make repairs to the satisfaction of the OCMI.
46 CFR 177.100
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2022
Resolution: Operator provided repair proposal and completed repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2022
Resolved
Repairs or alteration to the hull machinery, or equipment that affect the safety of the vessel must not be made without approval of the cognizant OCMI, except during an emergency. Vessel struck another vessel causing exterior and sail damage to vessel and other vessel received unknown damage. Vessel is not permitted to carry passengers prior to an MI conducting a damage assessment and internal structural exam. Vessel is required to complete an inspection of rigging and components prior to movement to drydock location and notify Coast Guard results of completing safety checks.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2022
Resolution: All repairs to scoop have been completed to the satisfaction of attend MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 October 2020
Resolved
All machinery and equipment must be installed and maintained to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. The starboard side engine mount was broken causing a safety hazard. Repair the engine mount to the satisfaction of the attending marine inspector. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 28 October 2020
Resolution: Engine mount replaced to engine manufactures specification.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 16 October 2020
Resolved
At each subsequent inspection for certification, the owner or managing operator must have the vessel ready for inspection of its fire protection equipment, including the following: inspection of each portable fire extinguisher to check for excessive corrosion and general condition. The operating station, 10-B:C portable fire extinguisher was corroded on the bottom and at the head due to weather exposure. Replace and maintain the extinguisher so that the extinguisher is ready for immediate use. 46 CFR 176.810(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 28 October 2020
Resolution: New 10 B:C extinguisher provided for operating station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 October 2020
Resolved
The installation of portable fire extinguishers must be to the satisfaction of the Officer in Charge, Marine Inspection. The operating station, 10-B:C portable fire extinguisher mount was corroded and did not safely secure the extinguisher to the vessel. Replace the mount to the satisfaction of the attending marine inspector. 46 CFR 181.520
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 28 October 2020
Resolution: New 10 B:C portable extinguisher and bracket installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2020
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which no floating waterlight is required. Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length but not more than 6 feet, securing the waterlight around the body of the vessel. The waterlight was attached with a lanyard, however, the lanyard was deteriorating due to sun exposure. Replace the lanyard to the satisfaction of the attending marine inspector. 46 CFR 185.700(d)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2020
Resolved 28 October 2020
Resolution: New ring buoy waterlight line installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 October 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot and Coast Guard Light List. Vessel master had electronic copies of both publications on a stand-alone computer with no ability to charge while underway. Vessel must keep paper back-up publications due to there being no outlets on the vessel.
46 CFR 184.420(a)(2)
46 CFR 184.420(a)(3)
NVIC 01-16 Encl. 1
Paragraph F
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2020
Resolved 28 October 2020
Resolution: Light list and Coast Pilot onboard and updated for 2020.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 16 October 2020
Resolved
The master or person in charge of a ship shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. The garbage placard was missing. Replace the placard to meet the requirements set forth by 33CFR151.59. 33 CFR 151.59
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2020
Resolved 28 October 2020
Resolution: New garbage management placcard installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 February 2020
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and internal structural at least once every two years. Vessel did not complete required drydock inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2020
Resolution: Dry Dock extended to May 2020 following successful completion of ISE on 11MAR20.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 17 September 2019
Resolved
The construction and arrangement of the vessel must allow the safe operation of the vessel in accordance with the terms of the Certificate of Inspection giving consideration to provisions for guards and rails and necessary facilities for passengers and crew. Crack witnessed in railings on stbd side. All defects and cracking on rails must be repaired at next dry dock to the satisfaction of the OCMI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2020
Resolved 18 May 2020
Resolution: Verified crack was properly repaired under activity #
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 September 2019
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46CFR160.050, or other standard specified by the Commandant. Forward ring life buoy grab line deteriorated and required replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2019
Resolved 20 September 2019
Resolution: Operator submitted photos to the CG showing replacement of grab line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 September 2019
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46CFR164.018 or other standard specified by the Commandant. Retroreflective material on two ring life buoys aft wasted and faded. Will require replacement to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2019
Resolved 20 September 2019
Resolution: Operator submitted photo of life rings in question with new retroreflective tape installed.