Records from 2003 to 2022. Most recent: inspection, 4 January 2022.
Inspection history · 14
4 January 2022
PSC B · COC-CHEM Renew
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7369629
16 April 2020
PSC B · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6938780
13 April 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6938946
25 February 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6915087
8 February 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6903394
22 April 2019
Ballast Water Examination · Administrative Inspection · Deficiency Check · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6666897
20 April 2019
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6666665
20 April 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6667473
19 September 2018
Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6543326
18 August 2014
COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4940835
29 December 2004
NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2266116
13 September 2004
COC-CHEM Annual · ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2195132
18 April 2003
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1774387
18 April 2003
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1776251
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 20 April 2019
Resolved
Contents of transfer procedures required by 33 CFR 155.750 must contain: (7) Procedures for topping off tanks. PSCOs attended vessel because the vessel was conducting bunker operations and during topping off 2S FO tank, approximately 125 gallons of FO spilled on deck and 40 gallons discharged into US waters. PSCOs requested topping off procedures from the CE. CE presented procedures that do not specify crew member responsibilities/roles/procedures after 90% volume is surpassed. Vessel is prohibited from conducting bunker operations until transfer procedures for topping off are provided.
33 CFR 155.750(a)(7)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2019
Resolution: Recieved bunkering procedure and e-mail corespondence from master stating procedures for bunkering contained all pertenant information.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 18 August 2014
Resolved
Ships shall carry at least two firefighting outfits. In addition, on tankers, two additional firefighting outfits shall be provided. Vessel is missing two out of four pair of pants, resulting in two of the required suits being incomplete.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 August 2014
Resolved 19 August 2014
Resolution: vessel provided proof of purchasing/obtaining 4 new and complete firefighting outfits IAW applicable requirements.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 13 September 2004
Resolved
The Sewage Treatment plant has not been properly maintained or serviced by the crew. They only add tablets when entering a US ports. Required the crew to start maintaining and servicing the system as required by the manufacturer.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 October 2004
Resolved 20 December 2004
Resolution: Received documentation via fax from vessel attesting to training of crew on the use of the Sewage Treatment Plant and proper maintainance of the Sewage Treatment Plant via Sewage log book.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 13 September 2004
Resolved
The rubber matting around all the electrical panels throughout the vessel is inadequate. It does not meet the requirements of SOLAS 2001 II-1 Reg 40, 45-1.3 or 45-2. Required the company to look into this and supply rubber matting for the protection of all personnel that come into contact with any electrial panel 440V and over.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 October 2004
Resolved 20 December 2004
Resolution: Rubber matting received and placed onboard.
Lifesaving › Launching Appliances › Release Mechanism
Issued 13 September 2004
Resolved
During the lifeboat drill one of the wire cables parted on the port lifeboat quick release. The crew as directed to replace the cable.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 October 2004
Resolved 20 December 2004
Resolution: Received documentation from vessel, via fax, attesting to renewal of the port lifeboat quick release wire.