MAURY USCG vessel records Sign in
← All vessels

TORM GERTRUD

TORM GERTRUD is a 2002 tank ship. The Coast Guard has recorded 33 inspections since 2003, most recently in August 2018, along with 13 deficiencies and 9 operational controls.

Records from 2003 to 2018. Most recent: inspection, 30 August 2018.

Built
2002
Last inspected
30 August 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9240885 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V3899
615898
Flag
SINGAPORE
—
Maury page id
psix-615898

Inspections, by type

…with no type recorded14
Years with a record 11 calendar years (2003–2018)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it30128 - Convention (Subpart B), Gross Ton
11742 - Convention (Subpart B), Net Ton
45990 - Dead Weight, Ton
55800 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

30 August 2018 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6527728
17 July 2017 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6211522
28 June 2014 ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4899540
27 May 2014 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4870737
20 February 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4248768
17 February 2012 Deficiency Check · Administrative Inspection · Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4246430
30 July 2009 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3550738
20 July 2009 ISPS II Exam · MARPOL Annex V Examination · COC-CHEM Annual · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3540475
20 April 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3456953
20 April 2009 ISPS III Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3458485
18 April 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3468368
2 March 2009 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3425203
22 October 2008 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3349731
22 October 2008 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3352102
7 August 2008 COC-CHEM Renew · MARPOL Annex II Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3293016
27 June 2007 Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2974440
7 September 2006 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2772125
27 July 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2726740
25 July 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2726374
28 May 2006 COC-TVE Annual · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2660504
27 May 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2660559
23 May 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2657228
27 June 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2405324
27 June 2005 ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2405403
11 May 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2355237
10 May 2005 COC-TVE Renew · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2349860
10 May 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2353809
9 May 2005 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2353519
7 May 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2351689
22 December 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2263680
23 June 2004 MTSA/ISPS Verification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2108518
19 May 2004 MTSA/ISPS Verification · Certificate of Compliance
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2072079
20 April 2003 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1774041

Deficiency record · 13

Lifesaving › Lifeboat › Propulsion Engine
Issued 17 February 2012 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. Free fall lifeboat engine will not start. SOLAS Cons. 2009 Ch III/20
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2012
Resolved 22 February 2012
Resolution: Flag administration has approved exemption for free fall lifeboat, while repairs are made to engine. In the mean time class report verifies that crew has been instructed on alternate mustering instructions and additional installation of life rafts.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 17 February 2012 Resolved
After any survey of the ship, no change shall be made in the equipment covered by the survey. Electric pressure washer has been installed in foward bosan locker with high pressure water line running the length of the cargo deck. Provide documentation that this installation is approved bearing in mind potential electric generation risk. SOLAS 2009 Cons. Ch. 1/11
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 March 2012
Resolved 22 February 2012
Resolution: Class has verified and approved the installation of pressure washer system.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 17 February 2012 Resolved
After any survey of the ship has been completed, no change shall be made in the machinery without sanction of the administration. Main engine stuffing box and filter have been removed. Class must attest to the approval of this engineering change. SOLAS 2009 consolidated Ch. I/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2012
Resolved 22 February 2012
Resolution: Class has verified the installation of stuffing box circulation pump and filter system and posted a placard explaining that it is not applicable to vessel''s engine.
Documentation › Logs/Records › Record Book of Engine Parameters
Issued 17 February 2012 Resolved
When applicable ships shall comply with the NOx Technical code. Changes in the engine parameters including engine part swaps are not being recorded in the approved IMO NOx technical file.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 February 2012
Resolution: File was reviewed by both class surveyor and vessel''s chief engineer. The technical file is being updated accordingly as per class report.
Deck/Cargo › Ballast › Tank
Issued 20 April 2009 Resolved
The vessel has a suspected leak in Ballast Tank #3 portside which is adjeacent to cargo tanks 4 and 5 portside . This poses and unsafe risk to the vessel and marine environment. The vessel is required to identify an make permanent repairs prior to conducting cargo operation in U.S. port Vessel is cleared to enter.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2009
Resolution: Received satisfactory survey from Class attesting to the permanent repairs to crack between Ballast Tank #3 portside and Cargo Tank #4 portside. Released vessel from Op Control.
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 20 April 2009 Resolved
Vessel was issued a NOV for the failure to immediately notify the nearest Coast Guard Marine Safety Office or Group Office of a Hazardous Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 22 April 2009
Resolution: LOU was received from vessel and approval prior to vessel departure.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 7 August 2008 Resolved
Demonstrate proper operation, including operational test procedure, for ship's ODME system. (NOTE: Attempt at simulation test indicates system fault. Class society report may be submitted to attending PSCO as evidence of resolution.)
Action required: 705 - Other - as specified
Due 7 September 2008
Resolved 7 August 2008
Operations/Management › Cargo Transfer/Lightering › Person in Charge Presence/Supervision
Issued 7 August 2008 Resolved
Follow shipboard procedures for ensure that a properly trained and qualified officer is in charge of ship's cargo transfer. NOTE: When USCG PSCOs boarded vsl during cargo txfr (offload), ship's 2nd officer was alone in CCR controlling txfr. 2nd officer does not have doc. evidence of having completed specialized oil tanker training per STCW 95, V/1.2.
Action required: 705 - Other - as specified
Resolved 7 August 2008
Resolution: Corrected on the spot.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 27 July 2006 Resolved
The vessel's speedlog is out of order. Must provide technician's report attesting to the repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2006
Resolution: recieved technician''s report.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 25 July 2006 Resolved
Vessel was issued a Letter of Deviation to enter and depart the Port of Corpus Christi with an inoperable speed log. 33CFR164.40. This is based on the understanding that the equipment will be repaired at the next U.S. port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2006
Resolution: Received Attestment letter from O/O stating repairs had been made to speed indicator and that it has been operating properly.
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 10 May 2005 Resolved
Provide transfer procedures in accordance with 33 CFR 155.750 prior to transfer operations to the satisfaction of a Coast Guard Inspector.
Action required: 705 - Other - as specified
Resolved 10 May 2005
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 10 May 2005 Resolved
Demonstrate proper operation of overflow and high level alarm to the satisfaction of a Coast Guard Inspector prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2005
Operations/Management › Port and Waterways Safety
Issued 19 May 2004 Resolved
INERT GAS WAS FOUND TO BE IN ACCESS OF 8% IN 03 OF 06 TANKS CHECKED (9% O2). ENSURE O2 CONTENT IS BELOW 8% IN ALL TANKS PRIOR TO CARGO OPERATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2004
Resolved 19 May 2004
Resolution: CARGO TANKS WERE INERTED TO O2 CONTENT BELOW 8%. DEFICIENCY CLEARED. 00 DEFICIENCIES REMAIN OUTSTANDING.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.