Records from 2017 to 2022. Most recent: inspection, 17 August 2022.
Inspection history · 19
17 August 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7536006
27 June 2022
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7489151
29 November 2021
PSC C
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7357125
15 November 2021
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7351234
28 October 2021
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7340601
13 March 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7157093
5 August 2020
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7022382
3 August 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7023180
31 July 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7019381
28 July 2020
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7094284
26 August 2019
Deficiency Check · Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6794690
22 February 2019
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6630315
11 December 2018
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6596521
3 December 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6588958
27 May 2018
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6447993
21 May 2018
ISPS II Exam · PII Safety Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6419466
20 May 2018
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6423401
8 April 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6120136
23 January 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6075125
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 June 2022
Resolved
Before ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Rescue boat throttle cable inoperable. 74SOLAS (2014 CONS. ED.) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2022
Resolved 18 August 2022
Resolution: Received Class report and pics of rectified rescue boat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 27 June 2022
Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no changes shall be made in the structural arrangements, machinery, equipment, and other items covered by the survey, without the sanction of the administration. PSCO observed nonapproved filler weld on fire main port side between frames 85 and 90. 74SOLAS (2014 CONS. ED.) I/11(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2022
Resolved 17 August 2022
Resolution: Received Class Report attesting and showing pictures of satisfactory repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 27 June 2022
Resolved
Survival craft, its launching appliance, and the area of water ino which it is to be launched shall be adequately illuminated. Rescue boat emergency light inoperable. Fixed while PSCO onboard. 74SOLAS(2014 CONS. ED.) III/16.7
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 2 July 2022
Resolution: Fixed While onboard.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 29 November 2021
Resolved
Please see Deficiency History for details #7340601
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 December 2021
Resolution: Received RO report and Hull service report confirming marine growth was removed from the vessel.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 28 October 2021
Resolved
The master, owner, operator, agent, or PIC of any vessel equipped with ballast water tanks that operates in the waters of the US must follow these practices: Remove fouling organisms from the vessel's hull on a regular basis and dispose of any removed substances IAW local, state and federal regs. PSCO members observed marine growth on the hull of the vessel.
33CFR151.2050(f)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 November 2021
Resolved 31 December 2021
Resolution: Received RO report and Hull service report confirming marine growth was removed from the vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 August 2019
Resolved
Electrical installations shall be such that the safety of passengers, crew, & ship from electrical hazards will be ensured. VDR panel behind wheelhouse had equipment removed with wires exposed & not properly secured.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 August 2019
Resolved 26 August 2019
Resolution: Electrician ensured that all wires were properly tagged out and capped off. Wire was proved to be a dead wire.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 26 August 2019
Resolved
Each incinerator subject to this parapgraph shall be approved by the Adminstration taking into account the standards specification for shipboard incinerators developed by the organization. The refractory material was found cracked & missing on the incinerator door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 3 September 2019
Resolution: Vessel sent in pictures of the incinerator door after the refractory material was replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 December 2018
Resolved
Such flexible pipes and end attachments shall be of approved fire-resisting materials of adequate strength and shall be constructed to the satisfaction of the administration. Supply line to fuel oil purifier had one soft patch. SOLAS74(2014)II-2/4.2.2.5.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2018
Resolution: Replaced supply line to fuel oil purifier.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 3 December 2018
Resolved
All ships of 500 gross tonnage and upwards shall have a rudder, propeller, thrust, pitch, and operational mode indicators to determine and display rudder angle. The indicators were not displaying the same angle as the rudder. SOLAS74(14)V/19.2.5.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 December 2018
Resolution: See Class Report attached to the document section of this activity.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2018
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection including fire resisting divisions. The galley door is required to be self closing and couldnt properly close. SOLAS74(14)II-2/14.2.1.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 December 2018
Resolution: See Class Report attached to the document section of this activity.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2018
Resolved
The condition of the ship and the equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Sea water pump connection box rusted and holed. SOLAS74(14)I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 December 2018
Resolution: See Class Report attached to the document section of this activity.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 3 December 2018
Resolved
The condition of the ship and the equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Sea water to fresh water generator has one soft patch. SOLAS74(14)I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 December 2018
Resolution: See Class Report attached to the document section of this activity.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 3 December 2018
Resolved
The condition of the ship and the equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Hot water heater had soft patches. SOLAS74(14)I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 December 2018
Resolution: See Class Report attached to the document section of this activity.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 3 December 2018
Resolved
The condition of the ship and the equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Sewage pipes near tank had soft patches.
SOLAS74(14)I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 December 2018
Resolution: See Class Report attached to the document section of this activity.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2018
Resolved
The condition of the ship and the equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Sea water service pumps had exposed wiring.
SOLAS74(14)I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 December 2018
Resolution: See Class Report attached to the document section of this activity.