Records from 2002 to 2012. Most recent: inspection, 8 June 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
8 June 2012
Drydock Exam · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4337354
21 May 2008
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3219374
4 June 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2951481
11 May 2007
COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2927645
10 May 2007
Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2922441
10 July 2006
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2707799
15 August 2005
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2464179
3 June 2005
Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2374379
16 June 2004
Deficiency Check · Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2130412
21 July 2003
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1853251
13 June 2003
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1815607
14 August 2002
Hull Examination · Simplified Stability Test · COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1813418
Communications › Audible Communications › Bell
Issued 8 June 2012
Resolved
Required to place bell on board.
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Vessel out of service since 22 OCT 2013
Stability › Unintentional Flooding › General
Issued 8 June 2012
Resolved
Required to ensure bilge alarms are operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2016
Resolution: Vessel out of service since 22 OCT 2013
Fire Fighting › Fire Bucket › Availability
Issued 8 June 2012
Resolved
Ensure all fire buckets are on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2016
Resolution: Vessel out of service since 22 OCT 2013
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 8 June 2012
Resolved
Ensure gas detector is operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2016
Resolution: Vessel out of service since 22 OCT 2013
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 May 2007
Resolved
Conduct Pre-Employment drug screening on new hires
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2007
Resolution: Received Fax copy of proof of pre-employment drug screening for crew member.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 10 July 2006
Resolved
Repair or replace three cracked windows in pilot house IAW 46CFR 177.1010, 1020, 1030.
Condition: Damaged By Earlier Event
Due 31 August 2006
Resolved 18 May 2007
Resolution: Replaced Glass over winter haul out.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 15 July 2005
Resolved
Provide test data for new carpet.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 August 2005
Resolved 30 August 2005
Resolution: Removed small aisle carpeting and plan to replace next year. Informed that they will need to provide test data for the new carpet when they install.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 July 2005
Resolved
Place ring bouy on all ring bouy's.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 August 2005
Resolved 12 August 2005
Communications › Audible Communications › Bell
Issued 15 July 2005
Resolved
Provide proper bracket for ships bell.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 August 2005
Resolved 12 August 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 June 2005
Resolved
Install line with halyard clip on ringbouy light per 46 CFR 180.70
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 August 2005
Resolved 12 August 2005
Operations/Management › Drills/Instruction › Fire
Issued 3 June 2005
Resolved
Provide record of training onboard for per 46 CFR 185.420
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 August 2005
Resolved 31 August 2005
Resolution: [name withheld] and deckhand [name withheld] conducted drills and training have it logged, all sat.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 3 June 2005
Resolved
Provide records/MIS reports for DAPI program.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 August 2005
Resolved 31 August 2005
Resolution: Provided documentation from Maritime Consortium, INC, all sat.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 3 June 2005
Resolved
Provide proof of annual servicing of fixed fire system.
Action required: 705 - Other - as specified
Due 1 August 2005
Resolved 12 August 2005
Electrical › Electric Generation Source (service) › Generator
Issued 16 June 2004
Resolved
Prove proper operation of Gen set.
Condition: Unknown
Due 16 July 2004
Resolved 16 July 2004
Resolution: Sighted this date.
[name withheld]
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 16 June 2004
Resolved
Obtain FCC Lic. for all masters.
Condition: Unknown
Due 16 July 2004
Resolved 16 July 2004
Resolution: Sighted this date.
[name withheld]
Lifesaving › Lifebuoys
Issued 13 June 2003
Resolved
HAD A PFD WATERLIGHT AND NOT AN APPROVED WATERLIGHT FOR A RING BUOY LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 July 2003
Resolved 21 July 2003
Resolution: Approved waterlight placed onboard.
Documentation › Markings/Placards
Issued 13 June 2003
Resolved
NO HAILING PORT ON THE STERN LEGACY COMPONENT DESC: Hull Identification Number (HIN)
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 July 2003
Resolved 21 July 2003
Operations/Management › Passenger Operations
Issued 13 June 2003
Resolved
NO PASSENGER COUNTER ON BOARD LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 July 2003
Resolved 21 July 2003
Engineering › Steering Gear System
Issued 13 June 2003
Resolved
STEERING ROD TOUCHED A TRIM TAB ASKED TO MOVE TO PREVENT CHAFFING LEGACY COMPONENT DESC: Bracket/Clamp
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 July 2003
Resolved 21 July 2003
Electrical › Electrical Distribution System (service)
Issued 13 June 2003
Resolved
OPEN ENDED WIRES NEEDED TO BE SECURED
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 July 2003
Resolved 21 July 2003
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 August 2002
Resolved
APPLIED FOR WITH MSC
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2003
Resolved 9 June 2003
Resolution: RECEIVED COD