← All vessels
GOL WORKER
Industrial Vessel · Miscellaneous Vessel class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named GOL WORKER
GOL WORKER is a 2003 industrial vessel. The Coast Guard has recorded 26 inspections since 2003, most recently in May 2026, along with 65 deficiencies, 1 operational control and 1 casualty investigation in 2026.
Records from 2003 to 2026. Most recent: inspection, 17 May 2026.
- Built
- 2003
- Last inspected
- 17 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 65 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2026
Identity
1140618
9297747 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDM5168
616389
Flag
UNITED STATES
366954010
Maury page id
psix-616389
Inspections, by type
…with no type recorded2
Years with a record
17 calendar years (2003–2026)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Registered dimensions (L × B × D)184.3 ft × 48.0 ft × 16.0 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)184.3 ft × 48.0 ft × 16.0 ft
ITC tonnagegross 1,101 / net 330
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 June 2026 · expires 30 June 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1601 - Dead Weight, Gross Ton
1101 - Convention (Subpart B), Gross Ton
76 - Regulatory (Subpart C or D), Gross Ton
330 - Convention (Subpart B), Net Ton
51 - Regulatory (Subpart C or D), Net Ton
1101 - Convention (Subpart B), Gross Ton
76 - Regulatory (Subpart C or D), Gross Ton
330 - Convention (Subpart B), Net Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDM5168MMSI 366954010 · active · compulsorily equipped · granted 4 August 2021, expires 4 August 2031
WDH2195MMSI 366954010 · cancelled · compulsorily equipped · granted 9 November 2013, cancelled 2 August 2021 · licensed under a name not among this hull’s recorded names (not shown)
WDB8162MMSI 366954010 · cancelled · compulsorily equipped · granted 4 June 2004, cancelled 4 November 2013 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 26
17 May 2026
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8377873
14 May 2026
Deficiency Check · Administrative Inspection · COI Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8351008
22 April 2026
Internal Structural Exam · Cargo Tank Internal · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8341194
19 November 2025
MTSA/ISPS Verification · Annual Inspection
Physical examination · Outer Continental Shelf National Center of Expertise · Activity 8266727
17 September 2024
Administrative Inspection · Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8003605
20 August 2024
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7985959
12 October 2023
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7807705
2 November 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7588209
15 July 2021
Drydock Exam · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7258334
18 September 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6553502
2 August 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5960273
19 October 2015
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5745606
27 July 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4392305
4 October 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3883450
5 August 2008
Deficiency Check · COI Inspection · Ballast Water Examination · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3283324
1 August 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3286253
10 July 2008
Internal Structural Exam · Hull Examination · Cargo Tank Internal · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3263532
17 September 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3073829
7 September 2007
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3052084
25 July 2006
Re-Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2719079
28 June 2006
Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2694703
7 September 2005
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2486634
7 October 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2216107
10 August 2004
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2161810
18 October 2003
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1933094
5 June 2003
Construction Oversight · Cargo Tank Internal · Initial Certification · Initial Construction-Excluding Oversight · Hull Examination · Internal Structural Exam · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1810436
Deficiency record · 65
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2026
Resolved
Each vessel must be designed, constructed and maintained to minimize fire hazards. The port generator (No. 02) has a fuel leak coming from the fuel rail. Repair.
46 CFR 127.220
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 May 2026
Resolved
Nothing in this part shall limit the inspector from making tests or inspections deemed necessary to assure the safety of the vessel.
Vessel P/Vs on methanol tanks were set to 3.0PSI where original design shows lower setpoint to 0.5. Lower set point and provide document of change prior to carriage of methanol.
46CFR 126.100
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 May 2026
Resolved
Pressure-relieving devices should be installed directly on a pressure vessel and so arranged that they cannot be readily rendered inoperative. The relief valves for both the port and starboard start air receivers were not installed directly on the pressure vessels, and both were in arrangements where installed ball valves could render them inoperative.
46 CFR 54.15.59(e) / 54.15.59(i)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 May 2026
Resolved
A vessel of less than 100 gross tons must have adequate emergency lighting fitted along the line of egress from machinery spaces below the main deck. Emergency light in the starboard steering passageway was extinguished.
46 CFR 129.440
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 May 2026
Resolved
At each inspection for certification the inspector shall examine to see that there is no accumulation of oil which might create a fire hazard. Gear oil was leaking from the fill and into the drip pan for the starboard generator (No. 01). Adjust fill level, and clean oil from pan.
46 CFR 91.25-45
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 September 2024
Resolved
The OCMI will insure that the vessel is in satisfactory condition and fit for the service for which it is intended. Both main generators were unable to to operationally ran or tested due to continued overhauls.
46 CFR 91.27-1(b)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 24 September 2024
Resolved
For an OSV assigned a loadline, see Subchapter E (Load Lines) for requirements for closure of openings, and the like. Starboard rudder inspection cover on deck had light coming through.
46 CFR 125.140
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 September 2024
Resolved
At each inspection for certification and periodic inspection, the inspector shall examine the bilges in the machinery spaces to see that there is no accumulation of oil which might create a fire hazard. Oil accumulation was found in the steering gear room on port side near centerline, oil leak underneath the aft thruster engine hydraulic pump, oil underneath main generators and passageway between generator space and main propulsion room.
46 CFR 91.25-45
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2024
Resolved
Each refrigerated space that is accessible to the vessel's personnel and that can be locked from the outside so that it cannot be opened from the inside, must have an audible alarm system that can be operated from within the refrigerated space. The installed audible alarm was inoperable.
46 CFR 113.45-5
46 CFR 113.45-5
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2024
Resolved
Each vessel must carry a lifejacket for each person on board. Berthing 5 on main deck had one lifejacket missing.
46 CFR 199.70 (b)
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 September 2024
Resolved
Each power motor for the main and auxiliary steering gear must have a “motor running” indicator light in the pilothouse that activates when the motor is energized. Motor running indicator lights were inoperable.
46 CFR 58.25-25(f)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 September 2024
Resolved
Where pressure-indicating gages are used, in no case must the upper range of the gage be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function. Starboard air receiver pressure gauge max psi reading is 165.
46 CFR 54.15-5(f)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2024
Resolved
The OCMI will ensure that the vessel is in satisfactory condition and fit for the service for which it is intended. Starboard main propulsion engine had a jacket water leak from jacket water tank cap.
46 CFR 91.27-1(b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2024
Resolved
Non-conducting deck coverings, such as non-conducting mats or gratings, suitable for the specific switchboard voltage must be installed for personnel protection at the front and rear of the switchboard and must extend the entire length of, and be of sufficient width to suit, the operating space. Switchboard did not have non-conducting mat at the front.
46 CFR 111.30-11
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 24 September 2024
Resolved
Owners and operators of applicable vessels must establish a master key control program. Vessel does not currently have a master key control system.
46 USC 3106(a)(1)
CVC Policy Letter 23-06
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2024
Resolved
The following are work list items and must be inspected by a Marine Inspector prior to receiving periodic inspection credit:
-02 main generators – offline due to thruster repairs and due to be overhauled. Unable to operationally test
-Items noted by ABS surveyor during Load Line survey: Watertight door gaskets, varying vent/ port hole gaskets, fuel vent flame screen as reported
-Name and hailing port of vessel on stern (missing)
-Breaker panel at operating station with breakers unlabeled
- Broken exhuast piping hanger noted within passageway
46 CFR 91.27-1(b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 September 2024
Resolved
Each lifebuoy must be marked in block capital letters with the name of the OSV and the name of the port required to be marked on the stern of the OSV under subpart 67.123 of this chapter. Two starboard side lifebouys require remarking.
46 CFR 133.70(a)(3)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 September 2024
Resolved
For each watertight door which is in a required subdivision bulkhead, an indicator light must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The indicator must show whether the door is open or closed. The engine room emergency door indicator arm was broken off and satisfactorily replaced while in attendance.
46 CFR 170.270(e)
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 12 October 2023
Resolved
Except as provided in paragraph (b) of this section, each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. This letter sets forth conditions of operation. During Annual inspection, Marine Inspectors (MIs) observed cargo on deck not in compliance with the vessel's Stability Letter maximum height limitations. Vessel shall provide evidence of compliance with the conditions of operation specified in the vessel's Stability Letter.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 October 2023
Resolved
Vessels must be equipped with independently driven fire pumps in accordance with Table 95.10–5(a). Upon arrival to inspection, crew self-reported primary fire pump was in-operable. Vessel has an auxiliary fire pump, which was tested and found to have significant leaks. Repair and operationally test both primary and auxiliary fire pump in the presence of a MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2023
Resolved
All marine engineering details such as pipes and fittings shall be designed, constructed and installed in accordance with the provisions of subchapter F. MI's observed a hydraulic leak at the STBD steering unit directional control valve at the gauge fitting. Vessel is to repair leak to the satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 October 2023
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03–1), except as otherwise provided by this subchapter. MIs observed two exhaust leaks, one per main engine. Repair exhaust piping.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 12 October 2023
Resolved
On all other vessels, similar examinations and tests shall be made at least once in every week, to include the entire steering gear, the whistle, and the means of communication between the bridge or pilothouse and the engine room. The date of the test and the condition of the equipment shall be noted in the official logbook. When requested by MIs, vessel was unable to produce adequately trained crew members ready to test emergency steering. Conduct crew training and perform emergency steering test in the presence of an attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 12 October 2023
Resolved
Indication of the rudder angle must be provided both at the main steering station in the pilothouse and in the steering-gear compartment. The rudder-angle indicator must be independent of control systems for steering gear. MIs observed both PORT and STBD rudder angle indicators to be reading inaccurate. Provide objective evidence that both PORT and STBD Rudder Angle Indicators are functioning properly.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 October 2023
Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. Systems of this type include the following: Steering Systems.
MIs observed the following:
1) Temporary repair on the PORT steering gear rudder angle indicator arrangement in the aft steering gear compartment.
2) Broken and/or missing safety pins on both PORT and STBD hydraulic actuator arrangements in the aft steering gear compartment.
Provide evidence of completed repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
Electric installations on vessels must ensure: (1) Maintenance of services necessary for safety under normal and emergency conditions. (2) Protection of passengers, crew, other persons, and the vessel from electrical hazards. MI observed a burned electrical outlet on the forward bulkhead of the engine room and several breakers not properly tagged out. Replace burned outlet and provide crew training on procedures contained within vessel's lockout/tagout program.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 November 2022
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Inspector observed a large amount of diesel fuel accumulated in the engine room bilge. Fuel and combustible liquids shall be removed from the bilge.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 November 2022
Resolved
Where fitted, it shall be the duty of the master to see that the emergency lighting and power systems are operated and inspected at least once in each week that the vessel is navigated to be assured that the system is in proper operating condition.- Emergency lighting for port bow life raft, and starboard rudder space are inoperable. Emergency lighting shall be repaired.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 November 2022
Resolved
Each vessel of less than 100 gross tons and less than 19.8 meters (65 feet) in length must have navigational lighting in compliance with the applicable navigation rules. Starboard, masthead and stern navigation lights were inoperable and shall be repaired.
Cite: 46 CFR 111.01-1(a)(2)
Action Code: 60 C
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 November 2022
Resolved
At each inspection for certification and periodic inspection the marine inspector shall conduct such tests and inspections of the main propulsion and (see Page 2)auxiliary machinery and of its associated equipment, including the fluid control systems, as he feels necessary to check safe operation. Marine Inspector (MI)was not able to verify operation of low lube oil shutdowns on all three generators, over speed shutdown on stern thruster engine and a coolant hose on the aft generator was leaking. Repairs shall be enacted and tests conducted to the satisfaction of the attending [name withheld]: 46 CFR 61.20-3(a)
Action Code: 60 C
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 November 2022
Resolved
The respective piping systems installed on ships shall have the necessary valves and flanges for safe and efficient operation of the vessel. Both steering hydraulic units, stern thruster, and port thruster have hydraulic leaks. Vessel shall repair leaks after a one-time round-trip voyage to the Gulf of Mexico Offshore Lightering Area to the satisfaction of attending [name withheld]: 46 CFR 56.01-1
Action Code: 17 C
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 2 November 2022
Resolved
Electric installations on vessels must ensure the protection of passengers, crew, other persons, and the vessel from electrical hazards. Exposed wiring in the navigation bridge steering console shall be removed.
Citation Number: 46 CFR 111.01-1(a)(2)
Action Code: 17 C
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 2 November 2022
Resolved
The respective piping systems installed on ships shall have the necessary valves and flanges for safe and efficient operation of the vessel. Sewage overboard valve is leaking from valve stem and shall be repaired.
Citation Number: 46 CFR 56.01-1
Action Code: 17 C
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 September 2021
Resolved
At least two life buoys on the vessel must be fitted with self activating smoke signals. Add bridge buoys and smoke IWO pilot house.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 17 September 2021
Resolved
All U.S. Flagged vessel which engage in domestic voyages by sea shall be applicable to the provisions of loadline. ABS has not issued the vessel its loadline after completion of drydocking.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 September 2021
Resolved
Each vessel must have a stability letter. ABS has not issued the updated stability letter after drydocking and conversion to mulit-cert vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 September 2021
Resolved
E lighting is required IWO life raft launching. New Life rafts were installed and no E lights are IWO. Install E-lights IWO life rafts
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 17 September 2021
Resolved
Each crew member shall be provide with a berth. 05 bunks were missing mattresses. Provide 05 mattresses on the 05 bunks without. Total persons allowed reduced to 17 until mattressed are onboard.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 October 2015
Resolved
ROX TEC blocks in forward engine room bulkhead had a purple wire penetration which was incorrectly installed. Replce the block and do not remove tomany layers.
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 October 2015
Resolved
Emergency escape hatch from Engine Room had a hole which was filled with silicone
Lifesaving › Lifebuoys › Serviceable
Issued 19 October 2015
Resolved
The grab lines on 02 Lifebuoys were missing clips which maintain the design standards of the approved lifesaving equipment.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 October 2015
Resolved
Guard on Liquid Mud pump broken providing no protection for spining shaft.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 19 October 2015
Resolved
Lube oil pressure gauge for the Port MDE indicates no pressure resulting constant alarm state. A sensor was installed from the STBD MDE which cleared the alarm. Obtain the parts and prove proper operation to the satisfaction of attending Marine Inspector.
Electrical › Electric Supply System (service) › Cable
Issued 19 October 2015
Resolved
Extension cords found being used as permanent wiring on bridge and a 6 way unit was installed overloading a receptacle.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 October 2015
Resolved
Rack light fixture rated for 60 watt bulb found with a 100 watt bulb installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 19 October 2015
Resolved
High pressure fuel lines missing bushing and bolts to reduce vibration and wear, on both Port and STB MDE's.
Construction/Loadline › Structures › Door
Issued 19 October 2015
Resolved
Gasket WTD AFT port Engine Room not the correct length leaving a 1/2 in gap.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 August 2008
Resolved
Prior to methanol operations, renew wiring and gasket in methanol pump as discussed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 5 August 2008
Resolved
Prior to conducting methanol operations, renew shaft coupling on methanol pump.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 August 2008
Resolved
Crop and renew 12" x 12" insert in watertight bulkhead below forward watertight door to engine room to the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 August 2008
Resolved
Prove proper operation with third party certification of oily water separator alarms to 15 ppm.
Communications › Public Address System › Loudspeaker
Issued 5 August 2008
Resolved
Renew PA speaker on bow.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 5 August 2008
Resolved
Provide all new ABS certificates when issued by class.
Lifesaving › Lifefloat › Serviceable
Issued 5 August 2008
Resolved
Repair or replace lifefloats as discussed.
Fire Fighting › Fire Main › Pressure
Issued 7 September 2005
Resolved
Repair fire pump pressure gauge in the wheel house.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 September 2005
Resolved
Prove proper operation of the emergency navigational lights as required by 46 CFR 129.310 (iv).
Engineering › Thrusters › Piping
Issued 7 September 2005
Resolved
Repair hydraulic leak covered with red hand epoxy at the #1 bow thruster elbow return line.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 7 September 2005
Resolved
Properly secure wiring for freezer and refrigerator compressors.
Communications › Internal Communications System › Sound-powered Telephone
Issued 7 September 2005
Resolved
Demonstrate proper operation of bow thruster sound powered phone blue flashing light.
Engineering › Thrusters › Hose
Issued 7 September 2005
Resolved
Renew both clutch hoses on stern thruster engine.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 7 September 2005
Resolved
Demonstrate proper operation of #2 and #3 liquid mud remote shutdowns.
Communications › Radio Communications › EPIRB
Issued 7 September 2005
Resolved
Install new hydrostatic release on EPIRB.
Electrical › Electrical Distribution System (service) › Cable
Issued 17 June 2003
Resolved
Properly secure wire and cable runs throughout the vessel
Engineering › Fuel Oil Service System › Hose
Issued 17 June 2003
Resolved
Provide proof that all hydraulic and fuel system hoses meet SAE J-1942 standards or install hoses that comply with the above standard.
Fire Fighting › Fire Pumps › Arrangement
Issued 5 June 2003
Resolved
Install pressure relief device on the fire monitor pump or prove that pump is not capable of exceeding 125 psi.
Casualty record · 1
17 May 2026Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 8377873
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.