OCEAN PRINCESS

OCEAN PRINCESS is a 2003 tank ship. The Coast Guard has recorded 52 inspections since 2003, most recently in October 2022, along with 30 deficiencies — 3 with no resolution recorded — and 12 operational controls.

Records from 2003 to 2022. Most recent: inspection, 5 October 2022.

Built
2003
Last inspected
5 October 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9268291 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A4373
616488
Flag
MARSHALL ISLANDS
—
Maury page id
psix-616488

Inspections, by type

…with no type recorded19
…past their stated due date3
Years with a record 14 calendar years (2003–2022)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8016 - Dead Weight, Ton
10979 - Displacement, Ton
5364 - Convention (Subpart B), Gross Ton
2518 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

5 October 2022 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7571800
8 September 2022 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7554528
3 August 2022 COC-TVE Annual · Deficiency Check · ISM Exam · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7522808
13 May 2021 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7195930
29 April 2021 COC-TVE Renew · PSC B
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7183661
19 July 2019 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6745528
22 May 2019 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6720898
26 April 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6669234
7 October 2018 PII Safety Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6556055
11 July 2018 Deficiency Check · ISM Exam · ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6469573
6 July 2017 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6199994
6 July 2016 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5930315
29 December 2011 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4214096
18 January 2011 ISPS III Exam · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3928571
18 January 2011 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3929078
11 January 2011 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3924557
26 November 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3898886
28 October 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3879655
29 September 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3859428
25 February 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3683675
11 February 2010 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3678566
10 February 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3677311
26 January 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3669939
18 December 2009 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · ISPS III Exam · COC-CHEM Renew · MARPOL Annex II Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3652279
12 January 2009 Loadline Exam · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · COC-CHEM Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3391333
30 October 2008 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3354211
13 March 2008 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3163776
6 February 2008 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3142887
17 January 2008 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3131956
17 January 2008 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3132086
1 January 2008 Ballast Water Examination · ISPS II Exam · MARPOL Annex II Examination · MARPOL Annex V Examination · COC-CHEM Renew · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3122432
21 August 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2754941
17 June 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2682601
25 May 2006 Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2653519
25 May 2006 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2653520
25 May 2006 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2675526
13 May 2006 Administrative Inspection · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2645908
12 November 2005 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2533254
6 October 2005 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2507467
7 April 2005 PII Safety Exam · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2328371
15 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2260044
15 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2308082
10 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2257269
24 May 2004 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2076988
14 January 2004 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1984792
13 January 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1983082
17 November 2003 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1949076
4 September 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1898051
2 September 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1894978
1 May 2003 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1784331
1 May 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1787038
28 April 2003 Ballast Water Examination · MARPOL Annex V Examination · Certificate of Compliance
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1782208

Deficiency record · 30

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 August 2022 No resolution recorded
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The starboard side lifeboat/rescue boat suffered severe damage due to a failure in the manual brake when being lowered to the water rendering it inoperable. Overnight, the lifeboat/rescue boat began to take on water due to the damage causing the engine to become completely submerged. 74SOLAS(2020 Cons.) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2022 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 August 2022 No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship and all respects will remain fit to proceed to sea without danger to the ship or persons on board. Hose station in upper engine room has a leak. In addition, fire monitor #1 was leaking when tested. 74SOLAS(2020 Cons.) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2022 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 August 2022 Resolved
Oil tankers...carrying cargos having a flashpoint not exceeding 60 degrees Celsius shall carry in lieu of totally enclosed lifeboat complying with the requirements of section 4.6 of the code, fire protected lifeboats complying with the requirements of section 4.9 of the Code. In addition to the requirements in 4.8 a lifeboat with a self-contained air support system... shall be so arranged that the air in the lifeboat remains safe and breathable and that the engine runs normally for a period of not less than 10 min. Both port and starboard side lifeboat oxygen systems were leaking through a T-flange. 74SOLAS(2020 Cons.) III/31.1.7 LSA Code 5.4.9.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2022
Resolution: Vessel replaced each flange with new thread tape and retightened the connections.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 3 August 2022 Resolved
The company and the ship shall comply with the requirements of the ISM Code. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Vessels SMS states oily water must be transferred to a slop tank or other suitable receptacle. Oily water was found stored in a trash can not designed for oil. 74SOLAS(20 Cons.) IX/3.1 ISM Code Part A 10.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2022
Resolution: Oily-water was placed in sludge tank and verified in vessels Oil Record Book.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 3 August 2022 No resolution recorded
Arrangements shall be provided to enable the pilot to embark and disembark safely. Starboard side pilot ladder has excessive wear and damage to the ropes. Port side pilot ladder has two steps split down the middle and not safe for use. 74SOLAS(2020 Cons.) V/23.3.1
Action required: 60 - Rectify deficiencies prior to movement
Due 3 August 2022 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 August 2022 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All lifesaving appliances prescribed in this part shall be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the Organization. Port side lifeboat has damaged retro-reflective tape. 01 life buoy on the starboard side has damages retro-reflective tape. 74SOLAS(2020 Cons.) III/34 LSA Code 1.2.2.7
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2022
Resolution: New retro-reflective tape was added to port side lifeboat and lifering.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed 03 power strips daisy chained together in the cargo control room and a dead end cable on the #1 main diesel generator in the engine room.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2021
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 April 2021 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. However, hold back arrangements fitted with remote release devices of the failsafe type may be utilized. PSCO observed open fire boundary door in cargo control room with hold-back hook permanently affixed under the overfill electrical alarm panel.
Action required: 10 - Deficiency Rectified
Due 29 April 2021
Resolved 29 April 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 April 2021 Resolved
After any survey of the ship under regulations 7,8,9, and 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. During test of the starboard slop tank high level overfill alarm, alarm did not worked as designed. PSCO discovered an unapproved bypass alarm switch inside of alarm panel switch not on electrical plan of alarm system. 40 a,b,c.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2021
Resolution: Received report from class. Rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2021 Resolved
The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the waters of the United States must follow these practices: Rinse anchors and anchor chains when the anchor is retrieved to remove organisms and sediments at their places of origin. PSCO observed fouled anchors.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2021
Resolution: Rectified.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 26 April 2019 Resolved
Each Tanker with VCS must be fitted with pressure-sensing Device, that mesures pressure in main VCS line. PSCO during the exam of the foam room noted strong gasoline odor coming from vapour/oxygen pressure detection Cabinet. PSCO suspended cargo operations due to 12% LEL reading and alarm on 4 gas meter. it was identified that plastic/rubber hose for sample line from port/stbd manifold within vapour/oxygen pressure detection cabinet for sensors measuring pressure were broken and cause of odor. Until repaired VCS System not to be used during Cargo Operations. 46 CFR 39.2013; 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 May 2019
Resolution: BV Provided Class Report of Proper Repairs and Operation of the Vapour/Oxygen Pressure Detection Pannel. Reference Attached Report in Documents.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Quality of fuel oil
Issued 11 July 2018 Resolved
2430 - While ships are operating within an emission control area, the sulphur content of the fuel oil used onboard ships shall not exceed 0.10% m/m on or after 01 January 2015. Bunker delivery notes showed for a period of over two years, from 02 March 2016 to 11 July 2018, the range of sulphur content from 0.30% m/m to 0.318% m/m. This fuel oil was being used within the United States Caribbean Sea Emission Control Area. A sample tested by a third party fuel supplier confirmed the last product bunkered was above the permissible limit. MARPOL 73/78 (17 COND) Annex VI/14.4.3 - 30ac
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 14 August 2018
Resolution: Vessel provided with bunkers at St. Croix with ultra low sulpher of 0.08%.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 11 July 2018 Resolved
2500 - Objective evidence discovered during an expanded ISM exam revealed the following non-conformities. These discrepancies, included with the other material deficiencies, are evidence the ship/company is not implementing the requirements of the ISM Code through the approved SMS procedures. An external audit is recommended. - 74 SOLAS 2014 IX/3.1 ISM CODE 1.3 - 30ac
Condition: Invalid
Action required: 30 - Ship detained
Resolved 14 August 2018
Resolution: During the external ISM audit guidance/obervations have been given to determine the effectiveness of the SMS in meeting the specific standards of safety and protection of the environment as required by the ISM Code.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 11 July 2018 Resolved
2500 - The Company should ensure that the environmental policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. [name withheld] reported onboard on 06 February 2018 and the Chief Engineer reported onboard on 31 May 2018. The Chief Engineer completed his familiarization check-sheet, the Master did not; neither were familiar with sections regarding bunkering procedures and operations. The Chief Engineer was not familiar with sections regarding bunkering on Safety management System Manuals, marine environmental protection requirements, or technical and practical information associated with pollution prevention. The prior to transfer checklists were filled out and included block 25 “the fuel oil fully meets the MARPOL Annex VI limitations on quality” while the vessel transited the United States Caribbean Emissions Control Area with High-Sulphur diesel fuel oil. The bunkering notes and related entries in the Oil Record Book, dating back to 02 March 2016, all noted the bunkering of High-Sulphur diesel fuel oil with over 0.10% m/m Sulphur content. ISM CODE 2.2 - 30ac
Condition: Invalid
Action required: 30 - Ship detained
Resolved 14 August 2018
Resolution: Master has completed familiarizations forms as required. Master & C/E have been trained onboard in regards to bunkering procedures.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Designated person(s)
Issued 11 July 2018 Resolved
2500 - The responsibility and authority of the designated person or persons should include monitoring the pollution-prevention aspects of the operation of each ship and ensuring that adequate resources and shore-based support are applied, as required. The company audit conducted 27 August 2017 indicated zero discrepancies. The company audit checklist indicates satisfactory results in the following section: F11 – all crew members are aware of MARPOL requirements applicable to their duties. The Safety Management System manual Ch. 7.4.2 states the company shall monitor the vessel’s bunker consumption and shall consult with the ship’s Superintendent to identify any additional requirements and consider whether Low-Sulphur fuel oil quantities should be ordered, and obtain the bunker supplier's confirmation that the issued bunker deliver notes will be in full compliance with the required scope of Appendix V of MARPOL Annex VI. The company failed to identify multiple environmental protection issues with MARPOL Annex VI, during review of bunker delivery notes in the period between 02 March 2016 and 11 July 2018. The vessel was using fuel oil with a sulphur content greater than 0.10% m/m during that time. ISM CODE 4 - 30ac
Condition: Invalid
Action required: 30 - Ship detained
Resolved 14 August 2018
Resolution: Panama and IMO Circulars related to MARPOL have been reviewed by complany's personnel and announced to ship's personnel and acknowledged receipt.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 11 July 2018 Resolved
2500 - The Company should clearly define and document the master's responsibility with regard to: implementing the environmental-protection policy of the Company; motivating the crew in observation of that policy; and verifying that specified requirements are observed. The company audit checklist indicates satisfactory results in the following section: F11 – all crew members are aware of MARPOL requirements applicable to their duties. The current master and previous masters did not identify that the ship was using non-compliant fuel for two years. ISM CODE 5.1 - 30ac
Condition: Invalid
Action required: 30 - Ship detained
Resolved 14 August 2018
Resolution: Training took place in regards to MARPOL and ISM requirements. Periodical internal audit to be carried out and relevant evidences to be attached to the internal audit reports in regards to results found.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 11 July 2018 Resolved
2500 - The Company should ensure that all personnel involved in the company's Safety Management System have an adequate understanding of relevant rules, regulations, codes and guidelines. The Captain and [name withheld] indicate they have reviewed relevant sections of the Safety Management System. The Safety Management System checklists and manuals show both company and mariner’s inadequate understanding of various sections: Chapter 5 – Masters Responsibility for ensuring all ship operations are carried out with due regard to protection of the environment. Master did not verify sulphur content was below required levels for operating within the United States Caribbean Emission Control Area. Chapter 7 – outlines requirements for bunkering Low Sulphur fuel oil, operations in Emission Control Areas, and the company’s requirement to monitor bunker and verify sulphur content for the vessels operation. The current and previous [name withheld] have been checking off the fuel bunkered was compliant with MARPOL Annex VI regulations when the stated sulphur content was not in compliance. ISM Code 6.4 - 30ac
Condition: Invalid
Action required: 30 - Ship detained
Resolved 14 August 2018
Resolution: Training took place onboard in regards to MARPOL and ISM requirements. Panama and IMO Circluars have been announced to ship's personnel with receipt and understood.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 July 2018 Resolved
2500 - In meeting these requirements, the Company should ensure that: any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken; and records of these activities are maintained. The Safety Management System requires non-conformities be reported. The Chief Engineer stated he reported an issue with the Oil Content Meter two weeks ago, and the company replied via telephone call. However, there is no documented record of the company addressing the non-conformity as required by the ISM Code. ISM CODE 10.2 - 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 14 August 2018
Resolution: Written communication and only has been established and supplemented to NCN and minutes of meetings provided to the company. Company proceeded to corrective action by purchashing new OCM which provided onboard, installed and tested.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 11 July 2018 Resolved
2500 - The Company should periodically evaluate the effectiveness of the Safety Management System in accordance with procedures established by the company. The company audit conducted 27 August 2017 indicated zero discrepancies. The Company audit checklist indicates satisfactory results in the following sections: F11 - all crew members are aware of MARPOL requirements, F14 - checking records of training crew environmental protection issues, F26 – Check bunkering procedures and their implementation (checklist, samples, Oil Record Book entries, etc.) Safety Management System Manual Ch. 7.4.12. The company failed to identify multiple environmental protection issues with MARPOL Annex VI during review of bunker delivery notes in the period between 02 March 2016 and 11 July 2018 when the vessel was using fuel oil with a sulphur content greater than 0.10% m/m. ISM Code 12.3 - 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 14 August 2018
Resolution: Panama and IMO Circulars related to MARPOL requirements have been reviewed by company's personnel and ship's personnel.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 11 July 2018 Resolved
1730 - After any survey of the ship under paragraph 1 of this regulation has been completed, no change shall be made in the structure, equipment, systems, fittings, arrangements or material covered by the survey, without the sanction of the Administration. The IOPP lists the MEPC.60(33) OCM as being covered under the survey. During calibration and testing of the oil content meter, the PSCO observed the content meter could not be zeroed out and did not react to the testing method used to verify effluent greater than 15ppm. The chief engineer identified this problem during weekly SMS checks on 30 June 2018 and requested a technician to attend/calibrate the content meter. The Recognized Organization has not been informed. MARPOL 73/78 (17 cond.) Annex I/4.2 - 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2018
Resolution: Vessel provided class report to rectify deficiency No. 03. PSCO observed proper operation of oil content meter. 01 deficiency cleared, deficiencies No. 02 and 03 remain outstanding.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 6 July 2017 Resolved
An Adult lifejacket shall be constructed so that wearer has quick and positive means of closure( that do not require tying of knots.) PSCO observed 22 lifejackets onboard that required the use of knots to properly be worn. 74 SOLAS III/2.1 LSA 2.2.1.5.4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2017
Resolved 8 July 2017
Resolution: Master supplied PSC Officers with reciepts for life jackets and letter from class approving them.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 18 December 2009 Resolved
3 of the 4 portable oxygen sensors were inoperable. Provide tech report stating units are working properly or provide invoice for new units.
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 11 February 2010
Resolution: Received receipts for new oxygen sensors.
Operations/Management › Cargo Transfer/Lightering › Use of Vapor Control System
Issued 18 December 2009 Resolved
Vessel unable to provide documentation that VCS is approved IAW 46 CFR 30. Vessel unable to conduct cargo operations that require VCS equipment in US water until system approved.
Action required: 705 - Other - as specified
Due 19 December 2009
Resolved 11 February 2010
Resolution: Received approval documentation for VCS from ABS.
Construction/Loadline › Hull › Side Shell
Issued 17 January 2008 Resolved
Submit CG-2692, report of casualty for allision to the Molasses Pier.
Due 22 January 2008
Resolved 19 January 2008
Resolution: Deficiency Cleared.
Construction/Loadline › Hull › Side Shell
Issued 17 January 2008 Resolved
Submit for review the; 1)Masters statement regarding the allision 16 January 2008 and 2) Hull condition Survey report prior to departure from the Molasses Pier.
Action required: 705 - Other - as specified
Resolved 19 January 2008
Resolution: Deficiency Cleared.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 1 January 2008 Resolved
Vessel is required to make ballast pumproom avaliable for inspection to include a valid marine chemist gas free certificate to the satisfaction of the attending Coast Guard marine inspector prior to departure from St. Croix.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2008
Resolved 2 January 2008
Resolution: Ballest pumproom inspected 02Jan08.
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 January 2008 Resolved
Founs salt water inlet for MDE airbox cooler is wasted and leaking salt water. Renew or repair pipe with in 14 days to the satisfaction of Class
Action required: 705 - Other - as specified
Due 15 January 2008
Resolved 18 January 2008
Resolution: Received ABS response to above def attesting to satisfactory repair.
Lifesaving › Lifeboat › Hull
Issued 1 January 2008 Resolved
STBD side lifeboat forward securing wire fitting is ripping through the fiberglass hull. Repair with in 14 days to the satisfaction of Class
Action required: 705 - Other - as specified
Due 15 January 2008
Resolved 18 January 2008
Resolution: Received report from ABS attesting to satisfactory condition of above def.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 October 2005 Resolved
BA LIGHT LIST IS NOT CURRENT, PROVIDE A 2005 LIGHT LIST.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2005
Resolved 7 October 2005
Resolution: RECIEVED LIGHT LIST RECIEPT FOR CURRENT LIGHT LIST FOR VSL
Engineering › Compressed Air System (start air)
Issued 1 May 2003 Resolved
Vessel to have the Class Surveyor test the starting air system in all modes/conditions, prior to the vessels departure from berth. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2003
Resolution: Received copy of ABS report NY-347894 stating that main engine starting was tested in all modes/conditions

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.