ISLAND GIRL is a 2000 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 2000, most recently in June 2025, along with 32 deficiencies and 2 casualty investigations between 2004 and 2012.

Records from 2000 to 2025. Most recent: inspection, 4 June 2025.

Built
2000
Last inspected
4 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB5816
Flag
UNITED STATES
367540580
Maury page id
psix-6177

Inspections, by type

…with no type recorded6
Years with a record 21 calendar years (2000–2025)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)28.0 ft × 11.5 ft × 4.9 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAARK MARINE, INC. · MONTICELLO, AR, UNITED STATES · built 2000
Hull materialAluminum
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portMUNISING, MI
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 22 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Net Ton
10 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG4834MMSI 367540580 · active · compulsorily equipped · granted 25 May 2022, expires 26 July 2032
WDB5816MMSI 366913780 · expired · compulsorily equipped · granted 25 November 2003, cancelled 25 January 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 37

4 June 2025 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8126554
13 February 2025 Hull Examination · Internal Structural Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8098611
11 September 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8004813
14 June 2023 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7744879
8 June 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7488876
22 June 2021 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7247820
11 May 2020 COI Inspection · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6951925
21 May 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6781951
27 December 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6603189
6 September 2018 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6538280
6 July 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6476754
15 May 2018 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6437663
2 October 2017 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6280099
6 September 2016 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5994281
10 August 2014 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4951188
8 August 2014 Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4947901
31 July 2012 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4397758
26 July 2012 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4391038
18 May 2012 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4315044
13 May 2009 Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3473996
14 May 2008 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3206485
19 June 2007 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2966721
16 June 2006 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2681693
7 September 2005 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2496013
7 August 2005 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2465664
6 June 2005 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2381625
22 June 2004 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2107340
7 June 2004 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2207755
26 February 2004 COI Inspection · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2026106
25 February 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1749400
20 June 2001 COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1410593
14 May 2001 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1422065
1 March 2001 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1373385
26 May 2000 Plan Review "T" Boat
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 817832
26 May 2000 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 817835
24 May 2000 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1397498
24 May 2000 Hull Examination · Initial Construction-Excluding Oversight · COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1462099

Deficiency record · 32

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 September 2024 Resolved
Stbd steering shaft carrier bearing through-hull has failed and vessel is slowly taking on water.
Action required: 10 - Deficiency Rectified
Due 18 September 2024
Resolved 18 September 2024
Resolution: POC fabricated new seal utilizing o-rings instead of graphite shaft seal.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 6 September 2018 Resolved
Provide drainage calculations attesting to minimum drainage standards. If freeing port modifications are required, any changes must be completed with CG Marine Inspector oversight/approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 27 December 2018
Resolution: Owner provided drainage calculation sheet demonstrating adequate drainage for vessel, verified by MI.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 September 2018 Resolved
Replace both bilge alarm indicators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 21 May 2019
Resolution: Bilge alarm indicators replaced and working satisfactory
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 6 September 2018 Resolved
Properly plug forward watertight bulkhead sluice valve.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 7 September 2018
Resolution: Received photo via e-mail confirming corrected def.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 2 October 2017 Resolved
Provide/install with approved bracket B-II PFE.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2018
Resolved 6 July 2018
Resolution: Owner called, attested to installation of proper extinguisher on June 30th, followed up by sending a picture on July 6.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 6 September 2016 Resolved
One PFE was partially discharged, replaced in kind during inspection.
Condition: Improper/Lack of Maintenance
Due 6 September 2016
Resolved 6 September 2016
Resolution: corrected during inspection
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 6 September 2016 Resolved
Condition: Improper/Lack of Maintenance
Due 6 September 2016
Resolved 6 September 2016
Resolution: corrected during inspection
Lifesaving › Lifebuoys › Stowage
Issued 6 September 2016 Resolved
Lanyard for float light did not encircle RLB body with clip at light, backwards, corrected.
Due 6 September 2016
Resolved 6 September 2016
Resolution: corrected during inspection
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 August 2014 Resolved
Provide report from qualified technician showing the port pressure switch on fixed CO2 system shuts down both main engines.
Due 20 September 2014
Resolved 23 September 2014
Resolution: Completed this date
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 August 2014 Resolved
Remove vent motor and associated wiring from fuel tank void and disconnect starboard CO2 system pressure switch.
Due 20 September 2014
Resolved 23 September 2014
Resolution: Completed this date
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 8 August 2014 Resolved
Install additional thermal insulation on exposed areas of both main engine exhausts where not water-cooled.
Condition: Improper Installation
Due 20 September 2014
Resolved 23 September 2014
Resolution: Completed this date
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 8 August 2014 Resolved
Replace starboard engine instrument display at operating station.
Due 20 September 2014
Resolved 23 September 2014
Resolution: Completed this date
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 May 2009 Resolved
Provide proof of enrollment in drug consortium
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2009
Resolution: Proof of enrollment provided.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 May 2009 Resolved
Provide valid C.O.D.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2009
Resolution: Valid C.O.D. provided.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 May 2009 Resolved
Provide proof of servicing for portable and fixed fire extinguishing equipment.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2009
Resolution: Servicing report provided.
Lifesaving › Lifebuoys › Serviceable
Issued 13 May 2009 Resolved
Provide adequate solas tape for life ring.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2009
Resolution: SOLAS tape provided.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 May 2009 Resolved
Conduct satisfactory MOB drill.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2009
Resolution: MOB drill completed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 May 2009 Resolved
Prove proper operation of navigational lights.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2009
Resolution: Nav lights operable
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 May 2008 Resolved
Provide new first aid kit.
Condition: Unknown
Due 14 June 2008
Resolved 20 May 2008
Resolution: New first aide kit provided.
Communications › Visual Communication › Signalling Lamp
Issued 14 May 2008 Resolved
Provide (02) portable lanterns.
Condition: Unknown
Due 14 June 2008
Resolved 20 May 2008
Resolution: Hand laterns provided.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 May 2008 Resolved
Provide labels for high water alarm indicators.
Condition: Unknown
Due 14 June 2008
Resolved 20 May 2008
Resolution: Alarm indicators labeled.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 May 2008 Resolved
Prove proper operation of aft high water alarm indicator light.
Condition: Unknown
Due 14 June 2008
Resolved 20 May 2008
Resolution: Indicator light was replaced and is operable.
Engineering › Fuel Oil Service System › Valve, Control
Issued 14 May 2008 Resolved
Remove clamps from fuel shutoffs.
Condition: Improper Installation
Due 14 June 2008
Resolved 20 May 2008
Resolution: Clamps were modified so as not to prevent the actuation of the shut-off valves.
Fire Fighting
Issued 20 June 2001 Resolved
PROPERLY SECURE BII FIRE EXTINGUISHER WITH MOUNTING BRACKET.
Condition: Unknown
Due 3 July 2001
Resolved 27 June 2001
Lifesaving
Issued 20 June 2001 Resolved
POST EMERGENCY INSTRUCTION LIST, COI, AND STABILITY LETTER.
Condition: Unknown
Due 3 July 2001
Resolved 27 June 2001
Engineering
Issued 24 May 2000 Resolved
INSTALL THE VENTILATION SYSTEMS FOR THE FUEL TANK COMPARTMENT AND THE ENGINE ROOM IN ACCORDANCE WITH 46 CFR 182.460.
Condition: Unknown
Due 30 September 2000
Resolved 22 September 2000
Fire Fighting
Issued 24 May 2000 Resolved
PROVIDE CG APPROVED PLANS FOR THE FIXED CO2 SYSTEM AND PROVE THE CO2 SYSTEMINSTALLATION IS IN ACCORDANCE WITH THOSE PLANS.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Navigation
Issued 24 May 2000 Resolved
INSTALL NAVIGATIONAL COMPASS AT PRIMARY OPERATING STATION.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Lifesaving
Issued 24 May 2000 Resolved
POST EMERGENCY INSTRUCTIONS AND CONDUCT EMERGENCY DRILLS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Navigation
Issued 24 May 2000 Resolved
PROVIDE CURRENT APPLICABLE NAVIGATION PUBLICATIONS AND CHARTS FOR INTENDED ROUTE.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Unknown
Issued 24 May 2000 Resolved
PAY ALL USER FEES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Navigation
Issued 24 May 2000 Resolved
INSTALL APPROVED VHF/FM RADIO.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000

Casualty record · 2

7 June 2004Routine · role: Involved in a Marine Casualty · activity 2207755
31 July 2012Routine · role: Involved in a Marine Casualty · activity 4397758
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.