MAURY USCG vessel records Sign in
← All vessels

ONEGO TRAVELLER

ONEGO TRAVELLER is a 2002 freight ship. The Coast Guard has recorded 41 inspections since 2003, most recently in November 2022, along with 30 deficiencies and 3 operational controls.

Records from 2003 to 2022. Most recent: inspection, 1 November 2022.

Built
2002
Last inspected
1 November 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9255725 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
618093
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-618093

Inspections, by type

…with no type recorded3
Years with a record 14 calendar years (2003–2022)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it8870 - Dead Weight, Metric Ton
11770 - Displacement, Metric Ton
6301 - Convention (Subpart B), Gross Ton
3582 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 41

1 November 2022 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7587399
3 August 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7523773
4 May 2022 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7444056
30 November 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7359564
18 September 2021 PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7314357
7 September 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7306222
20 February 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7143325
6 February 2021 Deficiency Check · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7135024
6 February 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7137651
8 December 2020 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7108454
15 August 2020 PSC B · Deficiency Check · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7033615
5 August 2019 COE-Administrative · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6764616
29 May 2019 ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6697734
11 March 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6640546
24 October 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6567436
23 July 2018 Deficiency Check · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6479670
16 May 2018 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6415687
9 May 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6404841
4 June 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4879349
12 May 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4851152
30 January 2012 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4234853
26 January 2012 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4232247
3 August 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4103036
25 November 2010 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3899366
29 November 2007 Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3104704
25 June 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2970295
3 May 2007 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2921777
16 October 2006 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2802563
8 September 2006 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2772980
8 March 2006 Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2598398
19 February 2006 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2588126
9 August 2005 ISPS II Exam · Random ISPS/MTSA/PSC
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 2456560
4 August 2005 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2523760
2 August 2005 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2443845
12 April 2005 Ballast Water Examination · Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2327142
12 April 2005 Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2327147
2 February 2005 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2285007
21 June 2004 MTSA/ISPS Verification · NPV Safety Exam
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2098908
12 June 2004 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2095851
13 May 2003 Annual Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1794119
29 April 2003 Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1782655

Deficiency record · 30

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 3 August 2022 Resolved
01-15108-ISM-The company should establish procedures to ensure that the ship is maintained in conformaty with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company(10.1) In meeting these requirements the company should ensure that: Inspections are held at appropiatre intervails (10.2.1) and any non conformity is reported, with its possible cause if known (10.2.2) Ships policies and proceduures manual SMM 3.5.1 and 3.5.3 gives guidance on ships procedures for conducting maintenance an inspections and reporting non-conformities on the fixed fire fighting systems. Ships SMS maintenance form 3.5.3 were completed on 30JUL2022 stating all relesing controls were in the proper position and readily accesible for immediate use. no records of non-conformitis were reported. As delinated in defeciency 2. The ship failed to identify a non conformity during routine maintenance of the fixed CO2 fire fighting system is required. 74 SOLAS (20) IX/3.1 705a,c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2022
Resolved 1 November 2022
Resolution: Class report recieved indicating deficiency was cleared by class. Also recieved SMS documents that were added to the ship's SMS related to the deficiency.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 August 2022 Resolved
2-07109 - Fixed fire extinguishing installation- Fire protection systems and fire fighting systems and appliancces shall be maintained ready for use. PSCO observed type "A" CO2 cylinder valve with the safety pins inserted in 20 engine room co2 bottles, preventing the activation of the CO2 system in the event of a fire in the engine room. 74 SOLAS (01) II-2/14.1.1 60a,c
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 5 August 2022
Resolved 5 August 2022
Resolution: Vessel provided class documenetation stating the vessel removed the safety pins off of the type A cyclinder valves and system is operable.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 February 2021 Resolved
03105 - Covers - The means for securing and maintaining weathertightness shall be to the satisfaction of the administration. The arrangements shall ensure that the tightness can be maintained in any sea condition. PSCO noted that the hatch cover to the CO2 room was no longer weathertight because the handle had been cut off. ICLL 66 Annex 1/16(4) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2021
Resolution: Crew replaced the handle. Hatch weather tight integrity now normal. See class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2021 Resolved
131990-Other (Machinery) - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO noted an oil leak on the valve supplying the circulating pump in the purifier room. 74 SOLAS(14) I/11(a) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2021
Resolution: Crew tightened the packing of the valve and no longer leaks. See class report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 February 2021 Resolved
06199 - Other (Cargo) - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO was notified that during the port state control examination, a hydraulic cylinder return line burst on the forward crane. Cargo operations were halted. 74 SOLAS (14) I/11(a) 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2021
Resolution: Crew replaced the damaged return piping with like new materials and tested. See class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 December 2020 Resolved
Under all sailing conditions, including manoeuvring, the speed, direction of thrust and, if applicable the pitch of the propeller shall be fully controllable from the navigation bridge. When sailing outbound on the Lower Mississippi River, the vessel reported a loss of primary pitch control from the navigation briedge. PSCO observed that the main pitch controller on the navigation bridge in inoperable. 74 SOLAS (97) II-1/49 (60ac)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 December 2020
Resolution: Controllable pitch main control was repaired. Several electrical connections have been retightened in previous port. Operational test satisfactory by class NKK. See docs for report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2020 Resolved
74SOLAS(04) II-1/26.1: The nachinery accociated piping systems and fittings shall be of a design and construction adequate for the sevice for which they are intended. PSCO observed an active hydraulic leak on the STBD side of the Coops & Nicborg gantrycrane. 13199
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2020
Resolution: Leak was repaired and tested to satisfaction of attending NKK class surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 15 August 2020 Resolved
74SOLAS(14), 1/11(a): The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remian fit to proceed to sea without danger to the ship or persons onboard. PSCO observed excessive corrosion and a 1'x2' hole covered with plastic and duct tape in the emergency fire pump space tank ventilation intake ventilation duct. Recommend the intake ventolation duct to be replaced prior to loading danderous cargo. 07116
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2020
Resolved 16 August 2020
Resolution: Temp repair was made and condition of class issued by attending NKK class surveyor giving vessel until 16OCT20 to make permanent repairs
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 May 2019 Resolved
Every oil fuel pipe, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space in the event of a fire. -Fuel oil shut-off valve did not trip on first attempt; 2nd and 3rd attempts were sucessful, and the team noticed an audible air leak from valve.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 31 July 2019
Resolution: Representatives of the vessel provided Class documentation attesting to rectification of the deficiency.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 16 May 2018 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained. The vessel was not able to get underwaydue to a faulty relay between bridge and engine control causing the CPP to pitch to 50% ahead on its own under bridge control.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2018
Resolution: The crew replaced the faulty relay with a ship's spare and tested the pitch satisfactorily with attending class surveyor.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 May 2018 Resolved
Piping systems & fittings shall be adequate for the service intended. The mechanical seal for the vessel's A/C cooling pump has failed. The crew rigged a fire hose from the fire & G/S pump suction piping to the A/C cooling pump discharge piping to provide A/C for the crew. The rigging (fire hose) was installed on 30APR18 & poses a threat of flooding to the crew and ship.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2018
Resolution: From class report: as a temporary measure, the section of fire hose was replaced with hard piping by the ship's crew to allow time for vessel to procure a new mechanical sea kit. A classNK recommendation was issued to repair the seal by 30MAY18.
Engineering › Bilge Water Management System › Piping
Issued 16 May 2018 Resolved
PIPING SYSTEMS SHALL BE OF AN ADEQUATE DESIGN AND CONSTRUCTION. PSCO OBSERVED PATCH ON BILGE/BALLAST EDUCTOR PIPING BETWEEN GATE VALVE AND SHIP'S SIDE SHELL IN WAY OF PORTSIDE BOTTOM DECK OF ENGINE ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2018
Resolution: from class report: [name withheld] stated that after the E/R crew cleaned the section of pipe in question (brushed to bare metal and repainted), that no patches were noted and pipe is in satisfactory condition. Attending ClassNK Surveyor noted as satisfactory.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 9 May 2018 Resolved
0611. 17ac. The normal equipment of every lifeboat shall consist of a food ration for each person. Lifeboat is rated for 26 people and only contains 11 rations. 78SOLAS 14CONS CH-III-34/LSA CODE CH. IV 4.4.8.12
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2018
Resolution: Received confirmation from master and class surveyor
Lifesaving › Lifeboat Equipment › Anti-seasickness Medicine
Issued 9 May 2018 Resolved
0611. 17ac. The normal equipment of every lifeboat shall consist of anti-seasickness medicine sufficient for at least 48 hours and one bag for each person. Lifeboat contains no anti-seasickness medicine. 78SOLAS 14CONS CH III REG 34/LSA CODE CH. IV 4.4.8.21
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2018
Resolution: Received confirmation from master and class surveyor
Lifesaving › Lifeboat › Carriage Requirement
Issued 9 May 2018 Resolved
0669. 17ac. On ships carrying at least two search and rescue locating devices and equipped with free-fall life boats one of the search and rescue locationg devices shall be stowed in a free fall lifeboat. Search and rescue locationg devices are located on navigation bridge. 78SOLAS14CONS CH. III REG 6.2.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2018
Resolution: Received confirmation from master and class surveyor
Operations/Management › Ballast Water Managment › Submission of Report
Issued 9 May 2018 Resolved
9900. 17c. Any vessel that is equipped with ballast water tanks and bound for ports in the United States must submit a ballast water report no later than 6 hours after arrival. Vessel did not report ballast to NBIC. 33CFR151.2060b(3)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2018
Resolution: Validated ballast report with NBIC
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 9 May 2018 Resolved
9900. 17c. Nontank vessels may not operate upon the navigable waters of the United States unless in compliance with a vessel response plan approved under 33CFR155.5065. Vessel does not have an approved vessel response plan. 33CFR155.5021
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2018
Resolution: MSU Savannah received NTVRP approval letter.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 9 May 2018 Resolved
9900. 10c. Vessel owners and operators must prepare and submit notice of intent unless a waiver is granted by EPA. Vessel is operating without an EPA vessel general permit and failed to subit an NOI. VGP Part 1.5.1.1 appendix E- NOI
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 9 May 2018
Resolved 9 May 2018
Resolution: PSCO provided training to vessel's master on preparing Notice of Intent and EPA's VGP requirements.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 9 May 2018 Resolved
9900. c. To discharge ballast water into the waters of the United States, the vessel must either ensure that the ballast water meets the ballast water discharge standard as defined in 33CFR151.1511(a), use an AMS or ballast exclusively with water from US public water system. Vessel shall not discharge water into waters of the United States until this requirement is met. 33CFR151.1512
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 July 2018
Resolution: Explain to the vessels master that the vessel may not discharge ballast water in the United States.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 May 2014 Resolved
1740- 15 PPM OCM- The oil record book indicated a malfunction on 15 PPM alarm on 24NOV13. C/E was unaware of what the malfunction was or if repaired. In addition C/E and crew unfamiliar with procedures to recall OWS history. Provide Corrective action plan and clarification from certificate issuing authority.- MARPOL 74/78 Annex I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 May 2014
Resolution: Received proper documentation satisfying the requirement.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 12 May 2014 Resolved
1611- Lifeboat Equipment- 15 lifeboat ration packages have lost the airtight seal.- 74 SOLAS (09a) III/31
Action required: 705 - Other - as specified
Due 26 May 2014
Resolved 12 May 2014
Resolution: Received proper documentation satisfying the requirement.
Electrical › Electric Supply System (service) › Cable
Issued 3 August 2011 Resolved
0950 - Electric equipment in general - All electrical apparatus shall be so constructed as so installed as not to cause injury when handled or touched in the normal manner. PSCO observed the 440v electrical connection on deck for the gantry crane was found to have exposed wiring which in turn could be hazardous to the ship’s crew. SOLAS 09 II-I(45)
Action required: 705 - Other - as specified
Due 10 August 2011
Resolved 5 August 2011
Resolution: Received, reviewed, and accepted class report from BV stating repairs were made to the Gantry crane 440v connection.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 3 August 2011 Resolved
1499 - Other (prop and aux machinery) - Every ship shall be provided w/ a main steering gear to the satisfaction of the admin. Ship’s crew was unable to operate steering in remote operation from the nav bridge. In PSCO opinion, remote steering needs to be certified by a technician. SOLAS II-I (29)
Action required: 705 - Other - as specified
Due 3 August 2011
Resolved 5 August 2011
Resolution: Received, reviewed, and accepted class report from BV stating the [name withheld] did not press the correct button to operate remote steering. Steering system was tested sat.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 3 August 2011 Resolved
1330 - Winches and Capstans - The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea. PSCO observed one capstan missing and one capstan inoperable (does not rotate). PSCO recommends vessel provides documentation attesting the proper repair & functionality of both capstans. SOLAS 09 I/II
Action required: 705 - Other - as specified
Due 10 August 2011
Resolved 5 August 2011
Resolution: Received, reviewed, and accepted class report from BV stating repairs were made to the exterior roller and a due date for the inner roller was set due to parts availability in NOLA.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 3 August 2011 Resolved
0199 - Other (certificate) - Each transfer pipe system must not leak under static liquid pressure at least 1.5 times the max allowable working pressure. Vessel could not provide documentation of liquid testing of fuel oil transfer pipes or cargo pipes. PSCO recommends that vessel provide test records to Coast Guard prior to bunkering or conducting bunker operations in the U.S. 33 CFR 156.170
Action required: 705 - Other - as specified
Resolved 30 January 2012
Resolution: Class report received and discrepancy has been cleared
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 16 October 2006 Resolved
Have Flag review minimum safe manning to increase engine room watch by one. Currently rotate a two person watch, not adequately fulfilling rest periods, need for possible additional person. STCW VIII/2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 May 2007
Resolution: Received licenses and safe manning certificate.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 16 October 2006 Resolved
Ship's Cook to provide documentation of cooking and victual preparation qualifications dual "AB- COOK" functions to be reviewed for possible rest period violations and conflicts. STCW VIII/2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 May 2007
Lifesaving › Immersion Suits › Quantity
Issued 16 October 2006 Resolved
Vessel has one immersion suit for all crew onboard however number of suits is not reflected in the SOLAS safety equipment certificate. SOLAS I/12
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 May 2007
Resolution: 12 immersion suits are onboard
Fire Fighting › Fire Hoses › Location
Issued 21 June 2004 Resolved
Fire hose station midship-port side as identified on the vessel's approved fire fighting plan was missing. No hose, nozzle, spanner wrench, or means of stowing equipment.
Due 21 June 2004
Resolved 21 June 2004
Resolution: Temporary installation of a fire hose, nozzle, and spanner wrench. Master to order a new fire hose station storage box for permanent installation.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 June 2004 Resolved
Missing oil discharge prohibited placard.
Due 21 June 2004
Resolved 21 June 2004

Ownership record