Records from 2003 to 2011. Most recent: inspection, 2 December 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200463
5 May 2009
Annual Inspection
Physical examination · Activities Europe · Activity 3485963
30 June 2008
MTSA Verification · COI Inspection
Physical examination · Activities Europe · Activity 3226128
10 July 2007
MTSA/ISPS Verification · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Activities Europe · Activity 2955293
23 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571513
8 July 2005
Annual Inspection · Hull Examination
Physical examination · Activities Europe · Activity 2382150
27 March 2005
Type not recorded
No type recorded · Activities Europe · Activity 2320546
3 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2302998
10 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290155
1 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232640
22 October 2004
Deficiency Check
Physical examination · Activities Europe · Activity 2225909
8 September 2004
Annual Inspection
Physical examination · Activities Europe · Activity 2233080
20 July 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2139314
7 June 2004
MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2059668
16 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1966884
16 April 2003
Initial Construction-Excluding Oversight · Initial Certification · MARPOL Annex I Examination · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1774709
Lifesaving › Launching Appliances › Release Mechanism
Issued 24 June 2009
Resolved
Provide USCG approved hydrostatic release unit for EPIRB. Report cleared via 16Jul E-mail , Item remains open until confirmed during next CG attendance
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 5 July 2010
Navigation › Piloting/Steering › Compass Deviation Table
Issued 24 June 2009
Resolved
Provide updated compass deviation card for magnetic compass. Report cleared via 01Jul E-mail , Item remains open until confirmed during next CG attendance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 5 July 2010
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 24 June 2009
Resolved
Provide search light for rescue boat, as required by 46 CFR 199.175. Report cleared via 01Jul E-mail , Item remains open until confirmed during next CG attendance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 17 August 2010
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 24 June 2009
Resolved
Update Vessel's abandon ship and survival training manual to reflect; specifically the provisions relating to the method of donning the lifejackets carried aboard, proper boarding launching and clearing of rescue boat, method of releasing survival craft from launching appliance, and the recovery of survival rescue boats, including stowage and securing. Report cleared via 01Jul E-mail , Item remain
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 5 July 2010
Lifesaving › Launching Appliances › Davit
Issued 24 June 2009
Resolved
Provide USCG Certificates of Approval for rescue boat davit, winch, and release mechanism, as required by 46 CFR 133.160(a). Report cleared via 24Jul E-mail , Item remains open until confirmed during next CG attendance
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 20 July 2010
Fire Fighting › International Shore Connection › Connection
Issued 24 June 2009
Resolved
Provide evidence of proper International Shore Connection, to include fire main connection and gasket. Report cleared via 22Jul E-mail , Item remains open until confirmed during next CG attendance
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 5 July 2010
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 24 June 2009
Resolved
Vessel's SOLAS Safety Radio Certificate does not indicate which Sea Areas the vessel is rated for. Report cleared via 05 Aug E-mail , Item remains open until confirmed during next CG attendance
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 29 July 2010
Communications › Radio Communications › EPIRB
Issued 24 June 2009
Resolved
Updated NOAA sticker to be placed on EPIRB. Report cleared via 21Jul E-mail , Item remains open until confirmed during next CG attendance
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 5 July 2010
Lifesaving › Rescue Boat Equipment › Thermal Protective Aid
Issued 24 June 2009
Resolved
Provide one thermal protective aid (TPA) for rescue boat. Report cleared via E-mail 28Aug, Item remains open until confirmed during next CG attendance
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 5 July 2010
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 24 June 2009
Resolved
Line throwing gun missing eight (8) cartridges. Report cleared via 24Jul E-mail , Item remains open until confirmed during next CG attendance
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 5 July 2010
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 June 2009
Resolved
Original copy of CSR number one (1) not on board. Report cleared via 23Jul E-mail , Item remains open until confirmed during next CG attendance
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2010
Resolved 5 July 2010
Communications › Radio Communications › Satellite Communications Capability
Issued 10 July 2007
Resolved
Demonstrate operation of the GMDSS Sat-C. Cleared by e-mail and changed due date for compliance to coincide with the COI expiration date so the next attending inspectors can verify on-scene.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2008
Resolved 30 June 2008
Communications › Radio Communications › Satellite Communications Capability
Issued 10 July 2007
Resolved
Demonstrate operation of the SSAS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2007
Lifesaving › Launching Appliances › Davit
Issued 10 July 2007
Resolved
Demonstrate slewing of the rescue boat davit. Reported as corrected by e-mail dated August 3, 2007.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2008
Resolved 30 June 2008
Communications › Alarms/Indicators › Fire Alarm
Issued 10 July 2007
Resolved
Demonstrate operation of the fire alarm in bow thruster room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2007
Communications › Visual Communication › Warning Sign (radio room)
Issued 10 July 2007
Resolved
Edit placard over toilet so that it reads no oil flushed in toilets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2007
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 10 July 2007
Resolved
Provide copy of Cummins test notes for main engines. Reported as corrected by e-mail dated August 3, 2007.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2008
Resolved 6 February 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 July 2007
Resolved
Replace missing eyewash bottles. Reported as corrected by e-mail dated August 3, 2007.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2008
Resolved 30 June 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 July 2007
Resolved
Replace missing saltwater intake on the main engine exhaust. Cleared by e-mail and changed due date for compliance to coincide with the COI expiration date so the next attending inspectors can verify on-scene.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2008
Resolved 30 June 2008
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 10 July 2007
Resolved
Update first aid kits. Reported as corrected by e-mail dated August 3, 2007.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2008
Resolved 30 June 2008
Construction/Loadline › Hull › Hull Plating
Issued 10 July 2007
Resolved
Crop and renew inset in way of the starboard side fresh water tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2007
Construction/Loadline › Hull › Hull Plating
Issued 10 July 2007
Resolved
Repair the fracture in way of the starboard generator exhaust.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2007
Personnel › Training › Fire Fighting Basic
Issued 2 September 2004
Resolved
Fire drill had to be redone.
Due 8 September 2004
Resolved 8 September 2004
Resolution: Second drill passed
Documentation › Manuals/Policy Documentation › Vessel Action Plan (SIP)
Issued 2 September 2004
Resolved
SOPEP audit not done.(worklist issuesd)
Due 9 September 2004
Resolved 9 September 2004
Resolution: Operator conducting audit.