Records from 2011 to 2026. Most recent: inspection, 15 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 69
15 June 2026
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8405243
5 June 2026
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8395463
26 March 2026
Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8332200
23 February 2026
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8314140
29 September 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8242070
22 September 2025
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8239022
25 August 2025
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8217807
24 June 2025
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8165883
23 June 2025
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8164985
14 March 2025
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8093642
23 January 2025
Excursion Permit · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8069156
22 January 2025
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8069677
10 December 2024
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8093581
8 December 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8045251
27 November 2024
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8040530
4 September 2024
Deficiency Check · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7987796
22 November 2023
Construction Oversight · Administrative Inspection
Physical examination · Activities Europe · Activity 7828514
10 October 2023
COI Inspection · Administrative Inspection · ACP Drydock Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7805765
7 August 2023
Re-Inspection · MTSA/ISPS Verification · ACP COI Oversight
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7745214
14 July 2023
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7825196
10 July 2023
Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7738933
2 May 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7679959
1 May 2023
Explosive Handling Operation-Commercial
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7676527
19 April 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7671389
27 February 2023
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7660737
21 February 2023
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7649837
31 October 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7587056
31 October 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7588349
27 September 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7566801
27 September 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7566827
11 December 2021
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7366242
11 December 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7438887
4 October 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7303674
29 July 2021
MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7272049
26 July 2021
Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7269958
17 May 2021
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7199459
30 November 2020
Damage Survey · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7104425
30 November 2020
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7105416
19 October 2020
MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7078707
14 February 2020
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6909523
30 December 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6880768
8 October 2019
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6805786
23 July 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6760134
21 June 2019
Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6721283
16 April 2019
Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6703384
6 April 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6663961
25 March 2019
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6648316
19 March 2019
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6656293
5 February 2019
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6620631
29 October 2018
Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6570831
24 October 2018
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6567644
13 August 2018
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6503485
10 July 2018
ACP Drydock Oversight · Administrative Inspection · Internal Structural Exam · ISM Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6450047
5 June 2018
Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6434933
28 May 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6434120
24 December 2017
Damage Survey · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6328507
11 December 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6279960
8 October 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6284882
8 October 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6284896
24 July 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6216445
23 July 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6307630
10 April 2017
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6119961
3 April 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6117097
28 March 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6113162
22 November 2016
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6046194
20 November 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6046949
24 October 2016
Administrative Inspection · ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6026545
10 August 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6013484
19 July 2016
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5946529
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 September 2025
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect unless the Admininistration is satisfied that such equipment is appropriately certified safe for usage in areas where gases are likely to be encountered. Lifebuoys located at port and starboard LNG bunker stations is not intended for Hazardous Locations. Vessel authorized to use existing lifebuoy lights for 30 days, but must remove them from location while bunkering LNG.
SOLAS 20 Chapter II-1, REg. 45.10.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2025
Resolved 8 October 2025
Resolution: ABS accepted as a condition of class.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 29 September 2025
Resolved
The conditions of the ship and its equipment shall be maintained to confirm with the provisions of the present convention. Oilly water separator pre-heater heat exchange has a leak.
MARPOL(73) 1/4.4(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2025
Resolved 8 October 2025
Resolution: ABS accepted as a condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 December 2024
Resolved
Smoke detectors shall be installed in all stairways, corridors and escape routes within accommodation spaces... The loop for the accommodation space smoke detectors is not functioning.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2024
Resolution: Received class report attesting to satisfactory repair. Condition partially rectified with due date of 16Jan2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 December 2024
Resolved
Vessel reported high
temps in #7 cylinder and associated scavenge airspace
due to failed liquid fuel injection nozzle which
required a slowdown/shutdown. 74SOLAS(20)II-1/26
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 December 2024
Resolution: Received class report attesting to satisfactory repair of the the main engine.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 November 2024
Resolved
All inlets and discharges led through the vessel's side shall be fitted with efficient and accessible means, located as close to the hull penetrations as is practicable, for preventing the accidental admission of water into the vessel either through such pipes or in the even of fracture of such pipes. The valve on the discharge side of the evaporator experienced a leak causing .4 cubic meters of water to enter the bilge in the engine room.
46 CFR 56.50-95
Action required: 17 - Rectify deficiencies prior to departure
Due 11 December 2024
Resolved 27 November 2024
Resolution: Received satisfactory Class Report of valve replacement.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2024
Resolved
The airlock shall be designed in a way that no gas can be released to safe spaces incase of the most critical event in the gas dangerous space separated by the airlock. Airlock did not latch closed.
74 SOLAS (20) II-1/57;IGF 2016/5.12
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2024
Resolved 5 September 2024
Resolution: Corrected prior to departure.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2024
Resolved
All elements of the level alarms, including the electrical circuit and the sensor(s), of the high, and overfill alarms, shall be capable of being functionally tested. Systems shall be tested prior to fuel operation IAW 18.4.3. Pre-bunkering checklist does not show to test high and overfill alarms for LNG storage tanks.
74 SOLAS (20) II-1/57;IGF 2016/15.4.2.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2024
Resolved 1 January 2025
Resolution: Received a copy of the pre-bunkering checklist with the required tests included.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2024
Resolved
Prior to conducting bunkering operations, pre-bunkering verification including, but not limited to the following, shall be carried out and documented in the bunker safety checklist:Operation of fixed gas detection equipment. Crew was unable to conduct a test of the fixed gas detection system in the Fuel Prep Space. Guidance IAW manufacturers instructions should be created for crew to conduct tests prior to bunkering and general testing.
74 SOLAS (20) II-1/57; IGF 2016/18.4.3.1.2
Action required: 705 - Other - as specified
Resolved 15 April 2025
Resolution: Crew now has the ability to test gas detection in Fuel Preparation Room.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 31 October 2022
Resolved
Fire-extinguishing appliances shall be available for immediate use at all times. One CO2 cylinder hose connection was loose and posed a substantial hazard to personnel in the event off a CO2 discharge, potentially filling CO2 space with CO2.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 31 October 2022
Resolution: Corrected on the spot. Chief Engineer tightened loose fitting.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 31 October 2022
Resolved
Each survival craft shall be stowed fully equipped as required by SOLAS, CH III and the LSA Code. Retro-reflective material required by LSA Code 1.2.2.7 is faded and does not reflect as required. SOLAS (20) CH III, Reg. 13.1.4.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 October 2022
Resolution: Bosun applied retro-reflective tape on all existing locations.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 16 December 2021
Resolved
74 SOLAS 14, I-11: "The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board." A survey of the stbd #6 ballast tank and the correlating port ballast tank shall be conducted by the USCG during next port call in the US (Long Beach, CA) to ensure continued structural integrity of the vessel has been maintained after permanent repairs were made.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2022
Resolved 18 January 2022
Resolution: Inspected both ballast tanks, confirmed no additional fractures or stressors were visible.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 December 2021
Resolved
74 SOLAS 14, II-1/3-1: "Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration..." Vessel reported a fracture in the hull IWO stbd #6 ballast tank. Vessel shall submit a proposal and affect permanent repairs of the stbd #6 ballast tank to the satisfaction of the attending marine surveyor. A failure analysis shall be conducted as well to identify causal stressors & structural failures that led to the hull fracture.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2022
Resolved 26 January 2022
Resolution: Vessel provided adequate failure analysis from MCA Consultants.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 4 October 2021
Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a class society which is recognized by the administration. Vessel has a fracture at frame #93 portside tunnel on container pedestal support bracket. Vessel is to make repairs to fracture to the satisfaction of the RO and email survey report to OCMI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2021
Resolution: Received ABS survey and cleared def.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 October 2021
Resolved
Stowage rooms of fire extinguishing medium spaces which are located below the deck shall be fitted with a mechanical ventilation designed to take air from bottom of the space. Identified a 3' section on ventilation pipe that corroded and fell off. Replace ventilation ducting to extend to the bottom of the space.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2021
Resolution: Received ABS survey clearing def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2020
Resolved
ALL STEERING GEAR COMPONENTS AND THE RUDDER STOCK SHALL BE OF SOUND AND RELIABLE CONSTRUCTION TO THE SATISFACTION OF THE ADMINISTRATION.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2020
Resolution: Replaced with OEM part, Op test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 8 October 2019
Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects remains fit to proceed to sea without danger to ship or persons on board. Battery selector switch on port side lifeboat failed and lifeboat was unable to start.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2019
Resolution: Replaced switch and submitted class report to proper operation
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 8 October 2019
Resolved
Every ship of 400 gross tonnange and above other than an oil tanker shall be provided with an Oil Record Book Part I (Machinery space operations). The Oil Record Book... shall be in the form specified in appendix III to this Annex. The ORB entries for OWS discharge overboard did not contain tank capacities nor quantities retained as required by ship's SMS procedures and MEPC.1/Circ.736/Rev.2. MARPOL Annex I/Reg.17.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 October 2019
Resolved 8 October 2019
Resolution: MI conducted training w/crew.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 October 2019
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. 3/E was unfamiliar with stowage location of life jackets and immersion suits at his watchstation; 3/E had been onboard for approximately 3 months. 74 SOLAS (2014) III/19.2.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 October 2019
Resolved 8 October 2019
Resolution: MI conducted training w/ 3/E.
Fire Fighting › Fire Main › Condition
Issued 24 December 2017
Resolved
Master of vessel reported pin hole leaks in way of Fire Station #19. Leaks are between valve and deck flange.
Action required: 705 - Other - as specified
Due 20 January 2018
Resolved 16 January 2018
Resolution: Repairs completed to the satisfaction of attending Class Surveyor. Class Survey Report attached under "Documents". See pages 37 and 38.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 December 2017
Resolved
Prove proper operation & the full closure of the identified ME Ventilation closures, as identified. Port #2 & #3 and STBD #2.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2017
Resolution: Received class report attesting to the satisfactory operation of all engine room ventilation louvers.